Call length counting – select whether the call should be counted in seconds or
minutes.
After call relax delay – interval between the current call termination and next call
setup via the same GSM/UMTS module. 2 seconds is recommended for high-
traffic installations.
Network settings
BTS lock – identify the BTS to which the GSM modules shall log in. Restart the
selected GSM modules to execute the changes.
Caution
The BTS lock service work with specific GSM modules only (Q55, Q24,
HE910, GE910)!
If you set a wrong BTS lock, the selected GSM module(s) will not log in
to GSM.
Network operator code (MCC+MNC) – set the local mobile network provider
code manually. If you do not enter a value, the provider will be selected
automatically.
Number of registration attempts – set the count of network registration
attempts if the network rejects to register the +CREG:3 SIM responses.
Delay after registration denied (1-600) [s] – set the registration delay, i.e. the
timeout within which the network may send another response after rejecting
+CREG:3.
Timeout for registration (10-600) [s] – set the maximum timeout for the module
to wait for network login in the NWAIT mode.
Next try for registration (0=off, 1-720) [m] – set the interval between relogging
attempts.
Enable USIM and SIM Application Toolkit – enable/disable the USIM and SIM
Application Toolkit services for the Telit HE/GE 910 modules.
Disconnect Call
Set the rules for automatic disconnection of outgoing calls to a wireless network.
SIM limit exceeded – automatic call disconnection when the active SIM card call
limit is exceeded.
Time limit exceeded – automatic call disconnection when the active SIM card
time of use is exhausted.
No ALERTING before CONNECT – automatic call disconnection when the
gateway receives the call connect message without alerting.
Send CLIP from VoIP to GSM/UMTS