2N Lift1 Compact Скачать руководство пользователя страница 7

 

 

Lift1 Programming 

Before you start 

 

Make sure that your phone supports tone dialing.  

 

Complete all the values to be modified into a pre-prepared form, which provides a clear table 
of basic functions.  

 

If your Lift1 is not brand new, make sure that you have the correct service password and, if 
you  are  not  completely  sure  of  your  Lift1  configuration,  execute  full  initialisation  (Warning: 
The service password will also be initialised!). 

Access to Programming Mode  

You can only enter the programming mode during an incoming call (from a phone to Lift1). Enter 
the access password:  

 service password 

 

(remember to enter an asterisk in front of and behind the password!)

 

If the password is correct and programming is enabled (jumper), Lift1 announces: 

„You have entered the programming mode“ 

and  displays  a  Help  according  to  the  context.  The  default  password  is  12345  and  you  are 
recommended to enter a different password to protect your device against unauthorised persons.  

Tips 

 

If you forget your service password, use the programming tool and PC with 2N® Service 
Tool.  

 

While entering the password, keep a timeout of 5 seconds (or any other value in the range 
between 1 and 9) for each character to avoid Lift1 hang-up and password/parameter re-
entering.  

Programming Procedure  

Having entered the programming mode, you can change any programmable value(s) in any order. 
Proceed  as  follows:  enter  the  parameter  number  and  value.  Use  an  asterisk  as  a  separator  or 
Enter. In general, the function has the following format: 

Parameter number 

 

value 

 

The parameter number has three digits (see the table). After you enter the number and an 
asterisk, Lift1 shall report the number/name, current value and potential range of the parameter 
to be programmed. After you enter the value and another asterisk, Lift1 shall announce “New 
value stored”, or “Invalid value” if the value is beyond the allowed range. 

Programming Error 

 

If you make a mistake while entering a number (function or value) and find it before 
clicking the asterisk, press 

 to cancel the whole number and enter a new one.  

 

If Lift1 rejects a parameter number or value, you can go on programming – enter the 
function number although you typed a wrong value. 

 

If you have programmed and saved a wrong value, re-enter a correct value. 

Programming End 

 

Having saved all the values to be modified, press 

 to make Lift1 send an on-hook signal 

and hang up.  

Содержание Lift1 Compact

Страница 1: ...2N Lift1 Compact Comunicator for Lifts Brief Manual Issue 2 Version 1 2 www 2n cz ...

Страница 2: ...sic version A PSTN or alternative PBX GSM gateway line is used for connection with the control centre Operation Press the ALARM button to activate connection The Wait pictogram goes on immediately and the Connection established symbol goes out when communication has been set up You can use automatic dialling of up to six pre programmed numbers Communication is accompanied by factory announcements ...

Страница 3: ...for cable passage Round the hole edges to avoid cable damage Mounting The product mounting procedure may not be commenced until all electrical installations have been completed Remove the connectors screw the wires and replace the connectors for facilitation Refer to Mounting Completion for further steps Safety The Cancel Alarm1 Alarm2 and Phone terminals and the electronics board are connected to...

Страница 4: ...ift travelling time For the Alarm 1 and Cancel input can be used switch button both with normally opened or normally closed contacts isolated The isolated voltage inputs can be activated by any voltage from 12 to 24 V The logic of inputs is to be set by parameters 920 for Alarm 1 916 for Cancel Connector NAME Description ALARM1 terminal DC voltage control 12 24 V DC any polarity activation by sign...

Страница 5: ...ting If you can access the cabin wall from the outside use the mounting type that prevents dismantling and unauthorised tampering from the cabin Mounting procedure Where access from the outside is possible use the four pre drilled M4 holes in the corners Remove the corner covers fitted with four M4 screws from behind Screw the 30 mm long M4 headless grub screws included in the audio unit package i...

Страница 6: ... the window forwards and remove it Now you have access to two holes in the window corners Put Lift1 on the pre drilled lift cabin wall holes and fit it with the included screws which are suitable for plywood chipboard laminated plastic etc walls For other materials use appropriate screws or M4 screws in the pre drilled M4 threaded holes Replace the window and insert the hex key wrench in the botto...

Страница 7: ...d keep a timeout of 5 seconds or any other value in the range between 1 and 9 for each character to avoid Lift1 hang up and password parameter re entering Programming Procedure Having entered the programming mode you can change any programmable value s in any order Proceed as follows enter the parameter number and value Use an asterisk as a separator or Enter In general the function has the follow...

Страница 8: ...nual 012 016 ALARM button memories 2 6 up to 16 digits empty 071 Check call memory 1 up to 16 digits empty 072 076 Check call memories 2 6 up to 16 digits empty 018 Count of automatic dialling cycles for ALARM 0 9 3 cycles 078 Count of automatic dialling cycles for check call 0 9 3 cycles 111 Automatic dialling type for ALARM button memory 1 1 6 1 1 loud with confirmation 2 silent with confirmatio...

Страница 9: ...sh 8 Portugese 9 Dutch 10 to 99 silence 877 Outgoing call message language selection 0 99 1 912 Maximum call time 15 990 s 120 s Use the call extending command to extend the call DTMF 4 or 913 Login time limit for automatic dialling 10 990 s 60 s Set the maximum period of time for the control centre staff to answer the call and send confirmation otherwise Lift1 hangs up and dials the next number C...

Страница 10: ...urs and then as set in parameter 983 3 enabled call as set in parameter 983 4 enabled call on the nearest day set in parameter 986 5 enabled first call in 3 minutes and then as set in parameter 986 6 as set by the server 982 Check call interval 00 00 00 23 59 59 beginning and end beg 00 00 0 0 end 23 59 5 9 Set announcements for the lower traffic lower tariff time generated at random in the set ti...

Страница 11: ...0 dB 2 5 2 0 dB 15 to 60 mA Overvoltage protection between A B 1000 V 8 20 μs Other Parameters Compact model dimensions 100 x 185 x 23 mm Working temperature range 20 to 70 C Note Lift1 is certified for connection to a wired PSTN line according to the ES 023 021 standard requirements The product does not contain components harmful to the environment When the product s service life is exhausted dis...

Страница 12: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Česká Republika Tel 420 261 301 111 fax 420 261 301 999 E mail sales 2n cz Web www 2n cz 2274v1 2 ...