2N Lift1 Compact Скачать руководство пользователя страница 3

 

 

Before you start 

Installation Conditions  

 

Lift1

 

is not intended for outdoor applications. 

 

As the product is connected to a telephone line and may thus produce life-endangering voltage, 
follow the safety precautions – refer to 

Safety Precautions

.  

 

Never connect Lift1 to a line in parallel with another terminal device. 

 

Make sure that the lift wall is perfectly flat. 

 

Make sure that the lift cabin installation is in compliance with the applicable lift standards. 
 

Tips 

 

Use a portable phone to make sure that the telephone line works. 

 

Make sure that you know the telephone line number to make a test call. 

 

Mounting 

Mounting preparation 

Drill  holes  into  the  lift  cabin  wall  according  to  the 
selected mounting type. If the cabin wall is accessible 
from the outside, you can use the corner holes for the 
M4 screws. If not, use the two holes in the middle for 
the  bolts  or  make  M4  threaded  holes.  See  the  1:1 
printing  on  the  product  package.  The  larger  hole  is 
intended  for  cable  passage.  Round  the  hole  edges  to 
avoid cable damage!  

Mounting 

The  product  mounting  procedure  may  not  be 
commenced until all electrical installations have been 
completed.  Remove  the  connectors,  screw  the  wires 
and  replace  the  connectors  for  facilitation.  Refer  to 

Mounting Completion

 for further steps.

 

 

Safety 

 

The Cancel, Alarm1, Alarm2 and Phone terminals and the electronics board are connected 
to  a  telephone  line  where  life-endangering  voltage  may  occur.  Where  switches  are 
connected  to  the  audio  unit,  make  sure  while  mounting  that  the  minimum  isolation 
distance  (from  the  telephone  line  connected  parts)  is  1.5  mm  and/or  the  minimum 
breakdown voltage is 1,500 V. This applies to the switches too! 

 

The  DC  controlled  terminals  are  separated  from  the  telephone  line  and  do  not  have  to 
meet the isolation requirements mentioned above. 

 

Make  sure  that  the  cables  cannot  get  in  contact  with  sharp  edges  during  installation  to 
avoid  insulation  damage.  Check  the  minimum  isolation  distance  of  1.5  mm  after 
installation using an isolation meter if possible. 

 

The manufacturer shall not be held liable for any  installations made in conflict with these 
instructions. 

 

 

Содержание Lift1 Compact

Страница 1: ...2N Lift1 Compact Comunicator for Lifts Brief Manual Issue 2 Version 1 2 www 2n cz ...

Страница 2: ...sic version A PSTN or alternative PBX GSM gateway line is used for connection with the control centre Operation Press the ALARM button to activate connection The Wait pictogram goes on immediately and the Connection established symbol goes out when communication has been set up You can use automatic dialling of up to six pre programmed numbers Communication is accompanied by factory announcements ...

Страница 3: ...for cable passage Round the hole edges to avoid cable damage Mounting The product mounting procedure may not be commenced until all electrical installations have been completed Remove the connectors screw the wires and replace the connectors for facilitation Refer to Mounting Completion for further steps Safety The Cancel Alarm1 Alarm2 and Phone terminals and the electronics board are connected to...

Страница 4: ...ift travelling time For the Alarm 1 and Cancel input can be used switch button both with normally opened or normally closed contacts isolated The isolated voltage inputs can be activated by any voltage from 12 to 24 V The logic of inputs is to be set by parameters 920 for Alarm 1 916 for Cancel Connector NAME Description ALARM1 terminal DC voltage control 12 24 V DC any polarity activation by sign...

Страница 5: ...ting If you can access the cabin wall from the outside use the mounting type that prevents dismantling and unauthorised tampering from the cabin Mounting procedure Where access from the outside is possible use the four pre drilled M4 holes in the corners Remove the corner covers fitted with four M4 screws from behind Screw the 30 mm long M4 headless grub screws included in the audio unit package i...

Страница 6: ... the window forwards and remove it Now you have access to two holes in the window corners Put Lift1 on the pre drilled lift cabin wall holes and fit it with the included screws which are suitable for plywood chipboard laminated plastic etc walls For other materials use appropriate screws or M4 screws in the pre drilled M4 threaded holes Replace the window and insert the hex key wrench in the botto...

Страница 7: ...d keep a timeout of 5 seconds or any other value in the range between 1 and 9 for each character to avoid Lift1 hang up and password parameter re entering Programming Procedure Having entered the programming mode you can change any programmable value s in any order Proceed as follows enter the parameter number and value Use an asterisk as a separator or Enter In general the function has the follow...

Страница 8: ...nual 012 016 ALARM button memories 2 6 up to 16 digits empty 071 Check call memory 1 up to 16 digits empty 072 076 Check call memories 2 6 up to 16 digits empty 018 Count of automatic dialling cycles for ALARM 0 9 3 cycles 078 Count of automatic dialling cycles for check call 0 9 3 cycles 111 Automatic dialling type for ALARM button memory 1 1 6 1 1 loud with confirmation 2 silent with confirmatio...

Страница 9: ...sh 8 Portugese 9 Dutch 10 to 99 silence 877 Outgoing call message language selection 0 99 1 912 Maximum call time 15 990 s 120 s Use the call extending command to extend the call DTMF 4 or 913 Login time limit for automatic dialling 10 990 s 60 s Set the maximum period of time for the control centre staff to answer the call and send confirmation otherwise Lift1 hangs up and dials the next number C...

Страница 10: ...urs and then as set in parameter 983 3 enabled call as set in parameter 983 4 enabled call on the nearest day set in parameter 986 5 enabled first call in 3 minutes and then as set in parameter 986 6 as set by the server 982 Check call interval 00 00 00 23 59 59 beginning and end beg 00 00 0 0 end 23 59 5 9 Set announcements for the lower traffic lower tariff time generated at random in the set ti...

Страница 11: ...0 dB 2 5 2 0 dB 15 to 60 mA Overvoltage protection between A B 1000 V 8 20 μs Other Parameters Compact model dimensions 100 x 185 x 23 mm Working temperature range 20 to 70 C Note Lift1 is certified for connection to a wired PSTN line according to the ES 023 021 standard requirements The product does not contain components harmful to the environment When the product s service life is exhausted dis...

Страница 12: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Česká Republika Tel 420 261 301 111 fax 420 261 301 999 E mail sales 2n cz Web www 2n cz 2274v1 2 ...

Отзывы: