2
Read this manual carefully before using the product and follow the
instructions and recommendations included herein. Refer to
wiki.2n.cz for full documentation on this IP intercom.
What You Need for Mounting
-
LAN connection, Cat5e or higher UTP cable with RJ-45
connector
-
PoE 802.3af or 12 V DC / 2 A power supply
Installation Procedure
-
Choose an installation site easily accessible to users.
-
Check the cable connection options: the device is equipped
with two cable bushings towards the wall in its bottom part.
-
Prepare the cables, LAN connection and power supply and
lock/accessory wiring if necessary.
-
Remove the metal device cover, open the lower blank module
as pointed by the arrows and introduce all the cables. Pull the
cables through the bushings. The manufacturer shall not be
held liable for defects incurred as a result of poor sealing.
-
Mount the device to the base.
-
Connect the cables and make sure that the device works
correctly.
-
Replace the blank and install the frame
.
Caution
-
Removing the front blank in the intercom bottom part make
sure that no impurities get onto the sealing and connectors.
-
When the proper mounting instructions are not met, water
might get in and destroy the electronics. The intercom
circuits are constantly under voltage and water infiltration
causes an electro-chemical reaction. The manufacturer‘s
warranty shall be void for products damaged in this way!
Mechanical Installation
The device is designed for wall (surface) mounting only and the
device alone is all you need for installation. A backplate (Part No.
9156020) is intended for easier installation onto uneven surfaces
and mounting boxes. Follow the backplate instructions
.
Electric
Installation
–
Description
of
Connector
Terminals
Description of motherboard connectors accessible to users:
-
802.3af LAN connector
-
Extending module connector (RFID card reader)
-
Tamper – internal tamper switch output
-
IN1 input terminals in passive/active mode (-30 V to +30 V
DC)
OFF = open contact OR U
IN
> 1.5 V
ON = closed contact OR U
IN
< 1.5 V
-
OUT1 active output: 8 up to 12 V DC, depending on the
power supply (PoE: 10 V; adapter: supply voltage -2 V), up
to 400 mA
-
RELAY terminals for 30 V / 1 A AC/DC NO/NC contact
Содержание IP Video Kit