Installation manual 2N® IP Uni
36
/
58
Tamper Switch Connection
2N
®
IP
Uni
is equipped with a tamper switch for detection of unauthorized penetration into the
device. After correct and complete installation of the device the tamper switch is closed. Tamper
switch opens immediately when the front panel is removed. Tamper switch contacts are
available on terminal block TAMPER SWITCH.
Device Resetting
2N
®
IP
Uni
is equipped with a RESET button. Push the button for 30 s to reset the factory default
values, deleting all the data stored in the
device.
Device Restarting
Press the RESET button shortly (< 1 s) to restart the system without changing configuration.
•
Note
Both outputs OUT1 and RELAY1 are switched always simultaneously.
•
Caution
In case of resetting the factory default settings on a device with a version of
firmware 2.18 or higher it is necessary to reprogram the
using the instructions from section
•
Note
The time interval between the short press of RESET and reconnection after restart
is 30 s for
2N
®
IP UNI
.