Installation manual 2N® IP Uni
31
/
58
1.
2.
3.
4.
5.
6.
7.
Mounting instructions:
a) If the cable wall outlets are located directly under the intercom to be installed, move
the cap from the middle hole to the bottom one to make way for the cables. Make sure
that no water can get into the intercom through the middle hole! The best solution is to
seal the hole perfectly with silicone, for example.
b) If the cables lead along the wall below the intercom level, put the template to the wall
in its normal position – the bushing will be on the bottom side.
c) If the cables lead along the wall above the intercom level, put the template to the wall
reversely – the bushing will be on the upper side.
Use an 8 mm drill to drill two holes of the minimum depth of 50 mm with the aid of the
template.
Push the dowels into the holes and attach the box and screws. Perfect the box position
using the oval holes before tightening the screws completely.
Connect the cables to the intercom as instructed.
Mount the intercom without the front panel to the box using the M4 screws included in the
delivery.
Screw the front panel onto the intercom.
Tighten the cable bushing properly to fix the cables especially where the bushing is on the
upper box side to avoid water leakage!
Содержание IP Uni
Страница 1: ...Installation manual 2N IP Uni v 2 16 www 2n com...