Mounting
– Electrical Installation
2.3
27
3.
Tighten the terminals using a flat screwdriver.
4.
Replace the terminal block to the printed circuit board.
Caution
Make sure that the cables leading through the 2N
®
Helios IP cover bottom
groove are installed properly. For the correct installation of the cables
refer to Figure 2.7.
Ethernet Connection
For the connections and meanings of the wires see the table below. Join UTP cable
wires 4 (blue) and 5 (white-blue) and attach them under terminal 7 on 2N
®
Helios IP.
In the same way, join wires 7 and 8 and place them under terminal 5 of 2N
®
Helios IP.
RJ-45
2N
®
Helios IP
Pin No. Marking Colour Terminal No.
1
Tx+
10
2
Tx –
9
3
Rx+
8
4
PoE –
6
5
PoE –
6
6
Rx –
7
7
PoE +
5
8
PoE +
5
Table 2.1
Terminal Block Connections
Electric Lock Connection
The electric lock can be connected to terminals 3 and 4 of terminal block X2.
Electric lock
2N
®
Helios IP
Marking Colour Terminal No
932070E
932080E
932090E
–
3
+
4
Table 2.2
Terminal Block Connection for Electric Lock
5
6
7
8
9
10
1
8
3
4