background image

2N® TELEKOMUNIKACE a.s., http://wiki.2n.cz

Page 4

How to configure 

Helios IP intercom – FW version 2.5

2N  

®

and older

Configuration of 

 intercom is very simple. Go to section "Basic settings – Switch 1" and verify that

Helios IP

2N  

®

this switch is enabled. Then you have to choose appropriate "Output relay" to which is 

Helios IP Security

2N  

®

 connected and set "Output type" to "Security" mode. After that you can also specify codes that will activate

Relay
the switch as is shown in the picture below.

Содержание Helios IP Security Relay

Страница 1: ...ing code is received Helios IP Security Relay 2N from the intercom Specifications Passive switch NO and NC contacts up to 30V 1A AC DC Active switch output typically 8 13 V DC depending on power supply adapter input voltage minus 0 6V max 700mA Dimensions 56x31x24mm Weight 20g Installation Install the onto a two wire cable between the intercom and the electric lock inside 2 Helios IP Security Rela...

Страница 2: ...put OUT1 or OUT2 or To the intercom relay output with a 12 V DC serial external power supply Connect the electric lock to the output as follows Helios IP Security Relay 2N To the active 12V 700mA DC output or To the relay output with a serial external power supply The device also supports a Departure button you can use our own order Helios IP Departure button 2N number is 9159013 connected between...

Страница 3: ...de both the red and green LEDs blink Activate the intercom switch by using the keypad telephone etc The first code sent from the intercom will be stored in the memory and considered valid After code initialization the Helios IP Security 2N will pass into the operational mode the green LED blinks Relay After these steps you can be sure that nobody will be able to open the door with 12V battery plac...

Страница 4: ... very simple Go to section Basic settings Switch 1 and verify that Helios IP 2N this switch is enabled Then you have to choose appropriate Output relay to which is Helios IP Security 2N connected and set Output type to Security mode After that you can also specify codes that will activate Relay the switch as is shown in the picture below ...

Страница 5: ...ion Hardware Switches Helios IP 2N Switch 1 and verify that this switch is enabled Then you have to choose appropriate Controlled Output to which is connected and set Output type to Security mode Finally specify codes Helios IP Security Relay 2N that will activate the switch as is shown in the picture below More product information Door Security Intercoms Official Website 2N ...