User Guide 2N® EasyGate PRO
80
/
87
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Power Supply
Mains supply:
230 / 12 V; 0.5 A adapter
DC power supply:
10 to 16 V DC
12V consumption:
Standby 90 mA
Call – typ. 300 mA, max. 600 mA
Data – typ. 200 mA, max. 400 mA
Battery charge – additional consumption 70 mA (Battery backup version only)
Supply connector:
DC Jack 5.5/2.1 mm, positive to center
When other power source than supplied adapter is used, the power source must meet
the criteria for SELV standard.
Battery backup (optional)
Accumulator type:
Charging cell NiMh size AA
Number of pieces:
4
Power consumption from batteries:
Standby – typ. 230 mA
Call – typ. 600 mA, max. 1200 mA
Data – typ. 350 mA, max. 800 mA
Charging current:
Typ.70 mA, regulated
Accumulators are not part of delivery.
Telephone interface
Interface type:
2-wire analog, FXS
Telephone connector type:
RJ-12, 6/2
Call impedance:
600
Ω
Loop voltage:
48 V DC
Loop current:
max. 40 mA
Loop resistance:
max. 800
Ω
Tone frequency:
adjustable, default 425 Hz
Dialing type:
tone (DTMF) and pulse
Ringing voltage:
42 Vrms 50/25 Hz
Calling line identification:
CLI during ringing according to ETSI FSK
Tariff pulses:
f=16/12 kHz ; Umin=100mVef on 200
Ω
Answer supervision:
polarity reversal, 12/16 kHz pulses
Содержание EasyGate Pro
Страница 1: ...User Guide 2N EasyGate PRO v 2 01 www 2n com ...
Страница 8: ...User Guide 2N EasyGate PRO 8 87 EasyGate LED indicators and EasyGate Connecters ...
Страница 25: ...User Guide 2N EasyGate PRO 25 87 ...
Страница 31: ...User Guide 2N EasyGate PRO 31 87 Default setting blank ...
Страница 35: ...User Guide 2N EasyGate PRO 35 87 Setting options 0 255 Setting step 1 Default setting 0 ...
Страница 37: ...User Guide 2N EasyGate PRO 37 87 ...
Страница 41: ...User Guide 2N EasyGate PRO 41 87 Default setting blank ...
Страница 79: ...User Guide 2N EasyGate PRO 79 87 SIM card 3V or 1 8V plug in ...
Страница 87: ...Uživatelský manuál 2N EasyGate PRO 87 87 ...