5.7 Services / Signaling
The Signaling folder is used for battery check activation and
2N EasyGate IP
®
connection to a mobile network.
Relay function – the relay is activated in the case of wireless network
disconnection or battery failure.
Relay state – state of the relay. The values are open/closed.
FXS line break function – the FXS line is disconnected in the case of wireless
network disconnection or battery failure.
disabled – the FXS line is not disconnected in the case of power or wireless
network failure.
power failure – the FXS line is disconnected (in approx. 3 s) in the case of
battery failure.
wireless network failure – the FXS line is disconnected in the case of
wireless network disconnection (in approx. 30 s).
power or wireless network failure – the FXS line is disconnected in the case
of power or wireless network failure.