background image

13

 Scenes & Rules

Triggering Devices from Events

A Scene can be run on its own, or “ Rules” can 
be assigned to trigger a  Scene after a Control 
Panel “event” such as arming your system or 
when an alarm occurs.

Creating Rules

Rules are created by assigning a Scene to run 
for an event that occurs.

To create a Rule, use the following steps:

1. 

From the Home Screen press the 

HOME 

SERVICES

 button.

2. 

From the Manage Z-Wave Devices Screen, press 
the  

RULES 

button.

3. 

From the Event Rules Screen press the  

ADD 

RULE

 button.

4. 

Use the 

 or 

 arrows to choose a system 

event to trigger the Scene. The events available 
are:
• System Armed Away
• System Armed Stay
• System Disarmed
• Exit Delay Started
• Entry Delay Started
• Fire or CO Alarm
• Alarm
• Audible Alarm
• Auxiliary Alarm
• Non-response Zone Opened
• Non-response Zone Closed

5. 

Use the 

 or 

 arrows to choose a Scene to 

run when the selected event occurs.

6. 

Press 

OK

 to create the Rule or 

CANCEL

 to quit.

7. 

Repeat Steps 3 through 6 to create additional 
Rules, or press 

BACK

 to quit.

Manage Z-Wave Devices Screen

Press RULES button

Add Event Rules Screen

Press ADD RULE 

button

Selecting an Event

Use arrows to select an event 

to trigger the scene

New Event Rules Screen

Selecting a Scene

Use arrows to select a scene 

that the event triggers

Event Rules Screen Showing New Rule

New rule

Содержание Go Control 2GIG-CNTRL2

Страница 1: ...Z Wave Home Services Operation User s Guide Wireless Security System 2GIG CNTRL2 ...

Страница 2: ...ave enabled household lights and appliances from the Control Panel or from a portable Z Wave remote controller An exciting feature of the Go Control Security System is the capability to remotely control your Z Wave network of devices from your own computer using a Web browser over the Internet This provides you with home automation control from anywhere in the world even through your Web enabled c...

Страница 3: ...witches 10 Z Wave Thermostats 10 Editing Scenes 11 Changing a Device s Action 11 Removing a Device s Action 11 Renaming a Scene 11 Running Scenes 12 Deleting Scenes 12 Triggering Devices from Events 13 Creating Rules 13 Editing Rules 14 Changing a Rule s Action 14 Deleting Rules 14 Network Maintenance Removing Devices 15 Network Diagnostics 16 Checking the Network 16 Advanced Setup Advanced Toolbo...

Страница 4: ...nabled devices in a home control network Each module can act as a wireless repeater that extends the range of the system and insures that commands intended for another device in the network are received The wireless range of Z Wave devices have a standard open air line of sight distance of 65 feet The actual performance in a home will depend on the type on construction amount of metal between devi...

Страница 5: ...staller The SWITCHES button will display the currently included binary and multi level switches The THERMOSTATS button will display the currently included thermostat devices The RULES button if enabled will display the currently programmed Rules that run Scenes after events The SCENES button will display currently programmed Scenes that run device actions The TOOLBOX button allows access to the Z ...

Страница 6: ... release the program button on the device This button may also be called bind learn or may not be labeled 4 When the device is discovered the display will show its kind type manufacturer and network node information assigned to the device 5 Repeat Steps 3 and 4 for any additional devices that need to be added to the network at this time 6 Press BACK when finished If additional Z Wave compatible de...

Страница 7: ...e 5 Use the alphanumeric keyboard to assign a name up to 40 characters to the device Use the arrow key to shift to capital letters Use the arrow key to shift to lower case letters Press the 0 9 key to access numeric and symbol characters Press the a z key to access alphabetic characters Use the DEL key to delete characters to the right of the cursor or delete highlighted text Use the BKSP key to d...

Страница 8: ... display the current status of the switch OFF or ON NOTE If the light or load is controlled at the module while the Control Panel is showing this display press the REFRESH button to update the display 4 Press the display where the device is listed to display the control buttons for the switch 5 A check box indicates if the switch is OFF or ON Press the desired action for the switch OFF or ON The l...

Страница 9: ...le while the Control Panel is showing this display press the REFRESH button to update the display 4 Press the display where the device is listed to display the control buttons for the switch 5 A check box indicates if the switch is OFF or ON If the switch is ON the dimming level with a number 1 12 will be shown below the check boxes Press the desired action for the switch OFF ON or adjust the dimm...

Страница 10: ...tatus current mode and current room temperature will be displayed NOTE If the controls at a thermostat are adjusted while the Control Panel is showing this display press the REFRESH button to update the display 4 Press the display where the thermostat is listed to display the control buttons for the thermostat 5 The display shows the current temperature the thermostat setpoint the thermostat mode ...

Страница 11: ...rent mode displayed 2 The temperature setpoint is immediately transmitted to the thermostat Setting the Fan Mode If the thermostat supports Z Wave fan control the fan mode selector will be displayed 1 Use the or arrows on each side of the fan mode display to choose between MANUAL AUTO MANUAL HIGH MANUAL LOW AUTO HIGH or AUTO LOW NOTE Only modes supported by the thermostat will be displayed 2 The t...

Страница 12: ...es as an action to the Scene Z Wave Switches 7A Use the or arrows to choose a switch device if there is more than one device then select an ON OFF or a dimming level for the switch Press OK Z Wave Thermostats 7B Use the or arrows to choose a thermostat device if there is more than one device then select a mode setpoint and fan setting for the thermostat Press OK NOTE The device will not activate w...

Страница 13: ... the HOME SERVICES button 2 From the Manage Z Wave Devices Screen press the SCENES button 3 A list of programmed Scenes will be displayed Press the name of the Scene to edit 4 Press the desired device s button to select it 5 Press DELETE ACTION A confirmation screen will be displayed press DELETE ACTION to confirm or CANCEL to quit without deleting Renaming a Scene 1 From the Home Screen press the...

Страница 14: ...ally NOTE Deleting a Scene will also delete any Rule associated with the Scene To delete a Scene use the following steps 1 From the Home Screen press the HOME SERVICES button 2 From the Manage Z Wave Devices Screen press the SCENES button 3 A list of programmed Scenes will be displayed Press the name of the Scene to delete 4 Press DELETE A confirmation screen will be displayed press DELETE SCENE t...

Страница 15: ...nt to trigger the Scene The events available are System Armed Away System Armed Stay System Disarmed Exit Delay Started Entry Delay Started Fire or CO Alarm Alarm Audible Alarm Auxiliary Alarm Non response Zone Opened Non response Zone Closed 5 Use the or arrows to choose a Scene to run when the selected event occurs 6 Press OK to create the Rule or CANCEL to quit 7 Repeat Steps 3 through 6 to cre...

Страница 16: ...lected event occurs the scene can also be edited here by pressing the Run this Scene button 6 Press OK to change the Rule or CANCEL to quit Deleting Rules Rules can be deleted individually To delete a Rule use the following steps 1 From the Home Screen press the HOME SERVICES button 2 From the Manage Z Wave Devices Screen press the RULES button 3 A list of programmed Rules will be displayed Press ...

Страница 17: ...and wait for a signal from a device 2 Press and release the program button on the device This button may also be called bind learn or may not be labeled 3 When the device is discovered the display will show A device has been removed from the network 4 Repeat Steps 2 and 3 for any additional devices that need to be removed from the network at this time 5 Press BACK when finished These steps can be ...

Страница 18: ...rk has detected trouble with 3 Press the trouble alert icon to display the device s the network has detected trouble with 4 Go to the displayed devices location s and inspect for un plugged or missing devices Either correct the devices installation or remove the device from the network using the following steps Press BACK to exit without making any changes 5 To remove a failed device press the dev...

Страница 19: ...rol Panel will display Learning Z Wave Controller and wait for a signal from the primary controller 2 Press and release the include button on the primary controller This button may also be called bind learn or may not be labeled 3 A confirmation screen will be displayed press OK Reset Controller Resetting the controller will remove all Z Wave devices from the network and controller The network nod...

Страница 20: ...e listed The controller listings will show the controller s name manufacturer and network node number 3 Press BACK to quit View All Devices Use the following steps to display all the devices programmed into the network 1 From the Advanced Toolbox Screen press the VIEW ALL DEVICES button 2 Each programmed device will be displayed Use the or arrows to scroll the display if more than three devices ar...

Страница 21: ...rent positions in the installation it is recommended to rediscover the network so the routing path will be re configured Use the following steps to rediscover the network 1 From the Advanced Toolbox Screen press the REDISCOVER NETWORK button The Control Panel will display Rediscovering Z Wave devices 2 The system will pause then return to the Advanced Toolbox Rediscovering Network Screen ...

Страница 22: ...nge buttons 16 R Radio compatibility 21 Rediscover network 19 REDISCOVER NETWORK button 19 Refresh button 6 REFRESH button 7 8 REMOVE DEVICES button 15 17 REMOVE FAILED DEVICE button 16 Removing a device s action 11 Removing devices 15 RENAME button 5 11 Repeater 2 Reset controller 17 RESET CONTROLLER button 17 RESET Z WAVE CONTROLLER button 17 Rules 2 10 13 RULES button 3 13 14 RUN button 10 11 1...

Страница 23: ...uarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Relocate the Console away from the TV radio receiver Plug the Console into a different wall out...

Страница 24: ...Copyright 2010 230786 X4 YOUR LOCAL ALARM INSTALLATION AND SERVICE PROFESSIONAL ...

Отзывы: