2 EASY
Input the master code
(Default:
#
# )
- All settings will restore to their
default value.
- When power on or activate
the reset all setting item,the
keypad checking will carry out,
during this time,the key
illumination will blink and the
touching operation is forbidden,
after finish checking,the key
illumination will stop blinking
and sent out a long sound of beep
- The master code is allowed 1~12
digits
. T
he same code cannot be
set for both the user code and the
master code
. I
t is recommended
that you
change
the default master
code
- The unlock time can be set on
both monitor and door station,
and the valid value is the number
you set last
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+
Beep+
Beep+
Beep+
Inputting of code (ex.: 10)
range:00 or 10~99
Inputting of code (ex.: 09)
range:01~99
3.Setting the key
illumination time
4.Setting the
unlock time
2.Setting the master code
(Default 1234)
(Default 10s)
(Default 1s)
Inputting of new master code
(ex.: 4321)(1~12 digits)
Input the setting code.
Inputting of code
Input the setting code.
1.Reset all settings
00+#
1234+#
4321+#
01+#
10+#
09+#
Input the setting code.
02+#
Input the setting code.
03+#
- If the key illumination time is set
to 00,the key illumination will light
up all the time when power on.
- If the key illumination time is set to
10~99,the key illumination will light
up for 10~99 seconds.At this mode,
the key illumination lights off in
standby mode, touching any digital
key can illuminate,but this is the
invalid digit.
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode
-
When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode
Beep, Beep+
*
-
When setting failure, the buzzer beeps
MODULES
DMR21 Technical M
a
nu
al
-7-