background image

2 EASY

CAMERA MODULE

Note: 

Key A and key B can not be seen on the panel,they are cryptic.

Normally,

 

key A and key B are not activ

e

To activate the buttons, 

just set the DIP6 to ON

 position

Attention: All settings will be canceled if the 

Restore Factory Setting

is

 activated. Include the modules setting,

 

such as 

Proximity

 module, 

Keypad  modul

e

 

(e

ven  if  the  modules  are  not  connected  to 

the 

Camera Module

)

When  in  standby  mode

, s

hort  out  the 

Exit Button Port(EB+,EB-)

then continuously toggle the DIP

-

6 switch for 4 times with a warning 

sound of BP+, and the three Indicators will blink at the same time, 

that means the 

Restore Factory Setting

 is in progress; If the three 

Indicators  turn off with a warning sound of BP+,it means the 

Restore 

Factory Setting

 is finished

Please know that the DIP6 switch must be set to ON while the others 

are set to OFF to carry on the following settings.

When the door station with 

Camera Module

 in standby

:

(1)Press Key A, the 

Unlock

 

indicator

 turns on with the warning sound 

of BP+, BP;

(2)Press Key A again to set the 

Unlocking Mode

 to 

Normally O

pen

or 

Normally  Closed

.  (

Normally  O

pen

:  the 

Status

 

indicator

  blinks 

ones

  with  the  warning  sound  of  BP+; 

Normally  Closed

:the 

Status

indicator

 blinks twice with the warning sound of BP+, BP)

If 

TFT Module

 is connected, the info will be displayed on screen

When the door station with 

Camera Module

 in standby

:

(1)Press Key A, the 

Unlock

 

indicator

 turns on with the warning sound 

of BP+, BP;

(2)Press 

and hold 

Key B to enter the 

Unlocking Time Delay Setting

, a 

warning  sound  of  BP  will  be  heard  and  the 

Status

 

indicator

blinks 

one time per second

The counting of 

Unlocking Time

 is the times that 

Status

 

indicator

blinks

 

(the units is second). For example,the 

Status indicator

 blinks 

for four times,that means the unlocking time is 4 seconds

When the door station with 

Camera Module

 i

n

 standby

:

(1)Press

 and holld

 Key A  for 3 seconds to enter the 

Warning T

u

ne

Option  Mode

,  the 

Status  indicator

  turns  on  and  the  current  tune 

will be

 play

ed

(2)Press Key A again to play next tune

(3)Press Key B to 

exit

When the door station with 

Camera Module

 is standby

:

 

(1)Press Key B to enter 

Tune Volume Setting

, the 

Talk indicator

turns on

 and 

play

s

 the tune at current volume

(2)Press Key A to increase/decrease volume

(3)Press B to exit

If 

TFT Module

 is connected, the current 

Volume 

will be displayed on 

screen

(1)During  conversation,  press

  and  hold

  Key  B

 

for  3  seconds  to 

enter the 

Talk Volume Setting

.

 The 

Talk indicator

 turns on with the 

warning sound of BP+,BP

(2)Press Key A to increase/decrease volume 

(3)Press Key B to exit

• 

 Unlocking Mode Setting

• 

 Unlocking Time Delay Setting

• 

 Warning T

u

ne Setting

• 

  Tune Volume Setting

• 

  Talk Volume Setting 

Speaker

Camera lens

Night view LED

MIC

Invisible key A

Status indicator

Talk indicator

Unlock indicator

Invisible key B

MODULES

1. Parts and functions

2. Settings via touch button

3. Restore

 to

 factory setting

DMR21 Technical M

a

nu

al

-5-

Содержание DMR21/D32/F1

Страница 1: ...21 F3 EP21 S12 DMR21 D32 F1 DMR21 D16 DMR21 S4 F1 DMR21 D8 F1 DMR21 TECHNICAL MANUAL Installation Guide 2 Modules 4 Camera Module 4 Keypad Module 6 TFT Module 11 Card Reader Module 12 Call Button Modu...

Страница 2: ...ontact of the relay NO Normally open contact of the relay EB Exit button positive connection port EB Exit button negative connection port JP LK Electic lock type setting SET DIP switches for door stat...

Страница 3: ...3 4 Cut a hole and install the wall box Final result Use the screws to fasten the panel Connect and plug bus line connector with cable Standard mounting RF CARD OFF ON OFF ON DBC4A A B C D DBC4A A B...

Страница 4: ...1 2 3 Exit button 12V LK GND LK COM N O EB EB Take off the Jumper JP_LK Cut off the line 1 2 3 Exit button INSTALLATION GUIDE DIP SWITCHES SETTING Totally 6 bits can be configured by dip switch The sw...

Страница 5: ...e in standby 1 Press Key A the Unlock indicator turns on with the warning sound of BP BP 2 Press and hold Key B to enter the Unlocking Time Delay Setting a warning sound of BP will be heard and the St...

Страница 6: ...red You should press confirm button after finish input ting the code number each time otherwise the operation will be cancelled automatically in 10s Setting items Setting range Default value Setting c...

Страница 7: ...e 01 99 3 Setting the key illumination time 4 Setting the unlock time 2 Setting the master code Default 1234 Default 10s Default 1s Inputting of new master code ex 4321 1 12 digits Input the setting c...

Страница 8: ...set last When the operation tone is set to 0 pressing the digital keypad will sent out a sound of beep When the operation tone is set to 1 pressing the digital keypad will blink one time Cancel all t...

Страница 9: ...ton Beep Beep Beep 11 SPK volume adjust setting Input the setting code Input the setting code 11 Inputting of code ex 5 range 0 9 5 Default 4 Unlock via password is still available even when the door...

Страница 10: ...second lock the second lock need external device to support If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be...

Страница 11: ...e list Press or to select name After that press to call the corresponding user Press Keypad Module to cancel the call This is the user interface of calling process Know that if the name list is create...

Страница 12: ...d on TFT screen When registered ID card will be presented to a Proximity Reader Door open message will be showed on TFT Display Module screen This is the user interface of adding card please know that...

Страница 13: ...on Show the MASTER CARD ADD it will sound BP the Talk indicator and the Unlock indicator will blink and after 10 seconds it will return to standby mode i By PC ii By SD Card Delete by room number Inpu...

Страница 14: ...w Mounting screw The DMR21 automatically assigns the call codes to the connected module s buttons Regardless of the structure of the call button mod ule the button numbers are listed from the top to b...

Страница 15: ...10 12 14 16 10 12 14 16 18 20 22 24 26 28 30 32 RF CARD RF CARD 01 02 03 04 01 02 03 04 01 02 03 04 05 06 07 08 05 06 07 08 09 10 11 12 13 14 15 16 1 2 3 4 5 6 ON 01 02 03 04 05 06 07 08 NO Functions...

Страница 16: ...witches for system configurations Connect to CN FUN of video entry module Connect to CN KMB of video entry module Connect to CN WGN of video entry module For electronic lock safety type setting Connec...

Страница 17: ...D16 DMR21 T4 D8 DMR21 ID S4 DMR21 ID KP INPUT INPUT OUTPUT OUTPUT CN KMB RF CARD OUTPUT INPUT INPUT CN KMB CN WGN INPUT OUTPUT INPUT CN KMB CN FUN OUTPUT INPUT CN WGN RF CARD A 1 2 3 4 5 6 0 7 8 9 B O...

Страница 18: ...1 2 3 4 5 6 0 7 8 9 B INPUT INPUT OUTPUT OUTPUT OUTPUT INPUT OUTPUT INPUT OUTPUT INPUT CN KMB CN FUN CN WGN RF CARD OUTPUT INPUT INPUT OUTPUT INPUT OUTPUT INPUT OUTPUT INPUT OUTPUT CN KMB CN WGN MODU...

Страница 19: ...want to call 001 Alan_1 08 00 01 Press the first button it would call the monitor 01 in BDU 1 and it is displayed Alan_1 on TFT module This section is reserved For more details please refer to the fo...

Страница 20: ...Insert SD card to slot iii A long warning sound of BP will be sent out and the Talk indi cator is turned on iii A long warning sound of BP will be sent out and the Status indicator is turned on iii Af...

Страница 21: ...witch to ON as the following picture shows ii Insert SD card to slot DIP6 ON 1 2 3 4 5 6 ON INPUT CN KMB CN WGN iii A long warning sound of BP will be sent out and the Talk indi cator is turned on iii...

Отзывы: