READINESS TEST 

__________________________________________________________________________________________________ 

 

Chromium™ Controller Readiness Test

  

 

 

Chromium™ Controller Accessory Kit 

 

Product 

Description 

Part Number 

Chromium™ Controller Accessory Kit 

 

 

110204 

 

Power Cord 

34000X 

 

10x™ Vortex Adapter 

330002 

 

10x™ Chip Holder 

330019 

 

10x™ Gasket (3 pack) 

 

10x™ Vortex Clip  

230002 

 

10x™ Magnetic Separator 

230003 

 

Chromium Test Chip V1 

230024 

 

 

Содержание Chromium Controller Readiness Test

Страница 1: ...Library Construction Chromium Controller Readiness Test FOR USE WITH Chromium Controller Accessory Kit PN 120223 ...

Страница 2: ...ides no warranty and hereby disclaims any and all warranties as to the use of any third party products or protocols described herein The use of products described herein is subject to certain restrictions as set forth in the applicable terms and conditions of sale accompanying the purchase of such product 10x 10x Genomics Changing the Definition of Sequencing Chromium GemCode Loupe Long Ranger Cel...

Страница 3: ...mium Controller Readiness Test 2 Chromium Controller Accessory Kit Product Description Part Number Chromium Controller Accessory Kit 110204 Power Cord 1 34000X 10x Vortex Adapter 3 330002 10x Chip Holder 2 330019 10x Gasket 3 pack 1 10x Vortex Clip 2 230002 10x Magnetic Separator 2 230003 Chromium Test Chip V1 1 230024 ...

Страница 4: ... with recommendations in the Chromium Controller Specifications b Turn on the Chromium Controller using the power switch on the back of the unit c The Chromium Controller touchscreen will indicate initialization is in progress d When initialization is complete press the button on the touchscreen of the Chromium Controller to eject the tray and remove the foam strip used for protection during shipp...

Страница 5: ...he Test Chip with the notch on the 10x Chip Holder and insert the left hand side of the Test Chip under the guide b Depress the right hand side of the Test Chip until the spring loaded clip engages the Test Chip c Close the hinged lid of the 10x Chip Holder After loading the Test Chip the 10x Chip Holder should lay flat on the bench top with the lid closed d Orient the assembly so that the Partiti...

Страница 6: ...e at the top left corner Hold the 10x Gasket by the tongue and hook it on the left hand tabs of the 10x Chip Holder Gently pull the 10x Gasket toward the right and hook it on the two right hand tabs Ensure the 10x Gasket holes are aligned with the wells 3 2 Run the Chromium Controller a Press the button on the touchscreen of the Chromium Controller to eject the tray Touch the touchscreen to wake u...

Страница 7: ...0x Gasket in the tray and press the button to retract the tray Confirm the Chromium Test program shows on the screen and press the play button to start the run d At the completion of the run 3 min the Chromium Controller will chime Press the button to eject the tray Remove and disassemble the Chip Holder assembly Press the button again to retract the empty tray After the run is completed press the...

Отзывы: