background image

Page 19

OWNER'S MANUAL

Warranty

One-Year  Warranty  -  This  Product  is  warranted  to  be  free  from  defects  in  material  and 
workmanship.  If it appears within one year from the date of original installation, whether or not 
actual  use  begins  on  that  date,  that  the  product  does  not  meet  this  warranty,  a  new  or 
remanufactured part, at the manufacturer’s sole option to replace any defective part, will be 
provided without charge for the part itself provided the defective part is returned to the distributor 
through a qualified servicing dealer. 

THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, 
removing, installing, shipping, servicing or handling of either defective parts or replacement 
parts.  Such costs may be covered by a separate warranty provided by the installer.  

THIS  WARRANTY  APPLIES  ONLY  TO  PRODUCTS  IN  THEIR  ORIGINAL  INSTALLATION  LOCATION  AND 
BECOMES VOID UPON REINSTALLATION.

LIMITATIONS  OF  WARRANTIES  –  ALL  IMPLIED  WARRANTIES  (INCLUDING  IMPLIED  WARRANTIES  OF 
FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO 
THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN.  SOME STATES DO NOT ALLOW LIMITATIONS 
ON  HOW  LONG  AN  IMPLIED  WARRANTY  LASTS,  SO  THE  ABOVE  MAY  NOT  APPLY  TO  YOU.    THE 
EXPRESSED  WARRANTIES  MADE  IN  THIS  WARRANTY  ARE  EXCLUSIVE  AND  MAY  NOT  BE  ALTERED, 
ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.   ALL 
WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING 
HOURS.    ALL  REPLACEMENT  PARTS,  WHETHER  NEW  OR  REMANUFACTURED,  ASSUME  AS  THEIR 
WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.

THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:

1.  Normal maintenance as outlined in the installation and servicing instructions or owner’s
     manual, including filter cleaning and/or replacement and lubrication.
2.  Damage or repairs required as a consequence of faulty installation, misapplication, 
     abuse, improper servicing, unauthorized alteration or improper operation.
3.  Failure to start due to voltage conditions, blown fuses, open circuit breakers or other 
     damages due to the inadequacy or interruption of electrical service.
4.  Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or 
     other conditions beyond the control of the Manufacturer.
5.  Parts not supplied or designated by the Manufacturer, or damages resulting from their use. 
6.  Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and 
     Canada.
7.  Electricity or fuel costs or increases in electricity or fuel costs for any reason whatsoever 
     including additional or unusual use of supplemental electric heat.
8.  ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY   
     NATURE WHATSOEVER.  Some states do not allow the exclusion of incidental or 
     consequential damages, so the above may not apply to you. 

This warranty gives you specific legal rights and you may also have other rights which may 
vary from state to state. 

S1-THEU21P7S

Содержание S1-THEU21P7S

Страница 1: ...ost Heat Pump Systems 1 Heat 1 Cool 2 Heat 1 Cool Digital Therm ostat Digital Therm ostat SystemPowered SystemPowered Controlupto2 Heat 1 Cool Controlupto2 Heat 1 Cool BacklitDigitalDisplay BacklitDigitalDisplay AuxiliaryHeatIndicator AuxiliaryHeatIndicator FahrenheitorCelsius FahrenheitorCelsius Model S1 THEU21P7S MODE HVAC SERVICE PARTS TM ...

Страница 2: ...e Period Programming Advanced Setup Overview Daily Programming Copying the Program Normal Operation Manual Operation Page Warranty Safety Warnings Location of Controls Display Programmed Operation Clock Set Advanced Features Factory Defaults Calibration ...

Страница 3: ...W THERMOSTAT WARNING Page 3 Safety Warnings OWNER S MANUAL This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation P N S1 THEU21P7S S1 THEU21P7S ...

Страница 4: ...N SET PROGRAM NEXT ON AUTO FAN Location of Controls Page 4 COOLER WARMER BUTTONS PROGRAM BUTTON Program OFF RUN program SET program MODE BUTTON Cool Off or Heat NEXT BUTTON On or Auto FAN BUTTON OWNER S MANUAL S1 THEU21P7S ...

Страница 5: ...tage heat is energized the Aux indicator will flash Indicates the Fan will run continuously Heat and Cool indicators In normal operation Heat or Cool appears When heat or cool is energized the Heat or Cool indicator will flash Day of the week Used for programming each of the 7 days of the week Time period indicators These indicate the part of the program that is currently active if the PROGRAM but...

Страница 6: ...l Off or Heat OWNER S MANUAL Manual Operation Program set to OFF Select Cool or Heat with the MODE button Normally leave the fan set to Auto In Fan Auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously Adjust the desired set temperature with the COOLER and WARMER buttons NEXT BUTTON FAN BUTTON S1 THEU21P7S ...

Страница 7: ...Fan On is selected the fan will run continuously The desired set temperature may be temporarily overridden The thermostat will revert to the programmed settings in the following time period Select RUN with the PROGRAM button Morning Day Evening or Night will appear on the display COOLER WARMER BUTTONS PROGRAM BUTTON MODE BUTTON NEXT BUTTON FAN BUTTON Program OFF RUN program SET program Cool Off or...

Страница 8: ...up screens Press NEXT to advance OWNER S MANUAL To slew the time more rapidly push and hold the COOLER or WARMER buttons This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section 6 00AM Su NEXT 6 00AM S1 THEU21P7S ...

Страница 9: ...lection press the NEXT button Each item in the time period programming screens will flash and can be modified with the COOLER WARMER buttons Continue the steps above until programming is complete Press the PROGRAM button twice to exit the programming screens and operate the thermostat according to the time period programming Press the PROGRAM button once to exit the programming screens and operate...

Страница 10: ...d Day setup screens page 9 Use these buttons to adjust the start time for the morning time period Use these buttons to adjust the cool setpoint for the morning time period Use these buttons to adjust the heat setpoint for the morning time period Press NEXT to advance Use these buttons to select the day of the week to be programmed M 6 00AM Morning M 78 6 00AM Morning SET COOL M 70 6 00AM Morning S...

Страница 11: ... to adjust the heat setpoint for the day time period Use these buttons to adjust the start time for the evening time period Use these buttons to adjust the cool setpoint for the evening time period Press NEXT to advance Use these buttons to adjust the start time for the day time period 8 00AM M Day 62 8 00AM SET HEAT M Day 85 8 00AM SET COOL M Day 6 00PM Evening M 78 6 00PM Evening SET COOL M NEXT...

Страница 12: ...etpoint for the evening time period Use these buttons to adjust the start time for the night time period Use these buttons to adjust the cool setpoint for the night time period Use these buttons to adjust the heat setpoint for the night time period 88 70 6 00PM Evening SET HEAT M i0 00PM M Night 82 i0 00PM SET COOL M Night 62 i0 00PM SET HEAT M Night NEXT NEXT NEXT NEXT S1 THEU21P7S ...

Страница 13: ... in previous steps flashing prompts for input will appear for the four time periods for the next day After programming for all seven days is complete press the PROGRAM button to leave the Setup screens If no buttons are pressed the display will leave the setup screens after 60 seconds Selecting Yes then pressing NEXT will copy the previous day s program If yes is selected again or each time this r...

Страница 14: ...rogramming you have two options 1 Run the time period program by pressing the PROGRAM button two times Or 2 Do not run the time period program by pressing the PROGRAM button one time The thermostat will operate as a manual heat or cool thermostat OFF RUN SET PROGRAM OFF RUN SET PROGRAM S1 THEU21P7S ...

Страница 15: ...t operation when a button is pressed OFF Light for 8 seconds after a button press ON Light continuously Use these buttons to select thermostat operation in degrees F or C Use these buttons to adjust the deadband from 1 to 6 degrees page 17 Press the PROGRAM button to enter the Advanced Setup When the clock is flashing press the NEXT button for 5 seconds Do not release the button until this screen ...

Страница 16: ...ure is equal to or less than the setpoint minus the 1st stage deadband one degree adjustable minus the 2nd stage deadband two degrees non adjustable Heat or Cool Setpoint Deadband Deadband db 1 db 2 adj 1 6 1st Stage turn on 2nd Stage turn on Heating non adj 2 Deadband db 1 adj 1 6 1st Stage turn on Cooling Press NEXT to advance Press NEXT to advance Press the PROGRAM button to exit Advanced Setup...

Страница 17: ...until this screen appears After restoring factory defaults the thermo stat screen will display all icons Press the PROGRAM button to return to normal operation Enter advanced setup by setting the PROGRAM button to SET When the clock is flashing press the NEXT button for 5 seconds Do not release the button until this screen appears 88 88 i8 88AM PM MorningEvening SET AUX HEAT COOL MTuWThF SaSu Day ...

Страница 18: ...EXT two times to advance Adjust the temperature reading using the WARMER and COOLER buttons then press the NEXT button to store the new value Press NEXT to store the new value When the Cycles Per Hour is flashing press and hold the NEXT button until this screen appears Enter advanced setup by setting the PROGRAM button to SET When the clock is flashing press the NEXT button for 5 seconds Do not re...

Страница 19: ...RSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owner s manual including filter cle...

Страница 20: ...rning Day Evening Night Copy Sat Sun No Yes Copy Wed Thu W E N E S D D A Y T U R H S D A Y Morning Morning Day Day Evening Evening Night Night No Yes DAY PERIOD HEAT START TIME COOL Copy Mon Tue M O N D A Y T U E S D A Y Morning Morning Day Day Evening Evening Night Night No Yes Programming Worksheet see Page 10 Printed on recycled paper P N 88 589 Rev 1 ...

Отзывы: