MANUGENX5 - Version 1.01 24.03.2021
© 2021 0N3 s.r.l. - Subject to change without notice
18
3.3
Selector
This is a 16 positions rotary switch with binary Outputs.
When the Wireless Handheld device is paired to a Base Station, the status of the Selector is replicated to the Base
Station as Safety Outputs (24Vdc High Side driver).
CAUTION!
•
User is responsible for interfacing the system to the machine control logic and implementing the State
Selecting function according to the safety level determined in a previous risk analysis.
• The Selector function should be only related to the selection of the various working modes available
on the machine by the logic controller.
•
The Selector and its related Outputs are Safety Modules, subjected to internal functional tests. In
case of hardware failure the Safety State Diagram Emergency state.
•
User can always access through the HMI to all diagnostics information about the safety module built
up by the Wireless Handheld and Base Station. In case of faults or failures user must always refer to
0N3 S.r.l. for maintenance and repair operations.
•
In order to avoid false fault detection the User must provide power supply to Selector Safety Output
even if they are not used.