The thermometer is a non-contact infrared thermometer. There are many mathematical modes for the Infrared function. Please 
remember to keep away from children and don’t use it for safety related applications. 

 

 

 
 
 
 
 
 
 
 

 
 
 
(Default Screen) 

Simply aim the thermometer at the measure target with Lens (

8

) and press Meas. key (

6

) to 

                                 

display the surface temperature. The Distance:Spot is 50:1. The two laser points are the reference for the target spot 

size.Please make sure the target area is within the field of view. 

 

FUNCTION  

Press Emissivity key (

1

) for setting the emissivity

 

 

Press Emissivity key (

1

), then press Up key (

4

) or Down key (

2

) to set the emissivity, then press Mode key 

(

5

) to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E). 

Press Mode key (

5

) for scrolling more display function as follows. 

 

Here will show the emissivity data. (The default emissivity is 0.95.) 

 

 

 

 

Press Mode key (

5

) for the Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and 

Average (AVG) modes. During the measurement, the special modes reading will be displayed beside the 

mode icon. 

 

 

Press Up key (

4

) or Down key (

2

) key to change the High Alarm (HAL) or Lo Alarm (LAL), then press Meas. 

key (

6

) to confirm it. For example: When the reading 26.9

o

C < LAL 27

 o

C, the Low icon will flash and you will hear 

a beep sound. 

 

Connect the thermocouple with Thermocouple socket (

11

) and put the probe in/on the target, the thermometer will 

display the temperature automatically without pressing any button. To see the minimum or maximum data during 
the probe measurement, please hold down the Up key (

4

) or Down key (

2

). 

  After measure high temp, the probe may remain HOT for a while. 

** The thermometer will automatically shut off if left idle for more than 60sec.ADD VALUE 

 

Press Up key (

4

) for LOCK mode ON/OFF.    The lock mode is particularly useful for continuous 

monitoring of temperatures for up to 60 minutes. 

In MAX, MIN, DIF, AVG 

mode: 

Press Down key (

2

) for 

o

or 

o

F transferred. 

and press Up key (

4

) for backlight function ON/OFF. 

 

In all modes: First 
hold on the Meas. key 
(

6

and press Down key (

2

) for laser function ON/OFF.   

(With flash light be turned on in the same time as laser ) 

 

 

 CAUTION 

1.

 

WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE TWO LASER BEAMS–PERMANENT EYE DAMAGE MAY RESULT. 

2.

 

USE EXTREME CAUTION WHEN OPERATING THE LASER. 

3.

 

NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.   

4.

 

KEEP OUT OF REACH OF ALL CHILDREN. 

STORAGE & CLEANING      The thermometer should be stored at room temperature between –20 to +65

 o

C (-4~149°F). 

The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should be taken when cleaning the 
lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do not 
submerge any part of the thermometer.   
LCD ERROR MESSAGES 
The thermometer incorporates visual diagnostic messages as follows: 

 

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the settings of HAL and LAL. 

 

 

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’ 
is displayed when the ambient temperature exceeds 0

o

C (32°F) or +50

o

C (122°F). The thermometer 

should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature. 

 

Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, wait for auto power 
off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error 
message remains please contact the Service Department for further assistance. 

 

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range. 

BATTERIES 
The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

 are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are not 

possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries. Please note: It 

is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

SPECIFICATION 

Item 

Non-contact Infrared Scan function 

Thermocouple Probe Scan function 
(K type; probe not included.) 

Measurement Range 

-60 to +1000

 o

C (-76 to +1832

 o

F) 

-64 to +1400°C (-83.2 to +2552°F) 

Operating Range 

0 to +50°C (32 to +122°F) 

Accuracy  
(Tobj=15~35°C, Tamb=25°C) 

±1.0°C (1.8°F) 

Accuracy 
(Tobj=-33~1000°C, Tamb=23±3°C) 

±2% of reading or 2°C (4°F) whichever is greater 

+/-1% of reading or 1°C (1.8°F) whichever is 
greater (Test under Tamb=23±6

°

C) 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

Resolution (-9.9~199.9°C) 

0.1°C/0.1°F 

Response Time (90%) 

1sec 

Distance:Spot 50:1 

Battery Life 

Typ.180, min 140 hours continuous use (Alkaline, without Laser and Back Light.) 

Dimensions 

47.0 x 197.0 x 203.3mm(1.8×7.7×8.0 inch) 

Weight 

386.1 grams(13.62 oz) including batteries (AAA*2pcs) 

Note:

 

Under an electromagnetic field of 3V/m from 90 to 360 MHz the maximum error is +/-10°C 

  EMC/RF

I

:Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

meter, but the performance of the instrument will not be permanently affected. 

 

 

 

 

 