background image

Inside

Tu

Day

Upstairs

Auto

Downstairs

Airflow %

HEAT

Schedule

AUTO

FAN

MENU

MODE

Heat

Set To

SYSTEM

AM

365

Comfort

UP/DOWN

 Keys.

SYSTEM MODE

 Key

OFF, HEAT, COOL or AUTO

Displays the downstairs 
(Inside) or upstairs (Inside2)
temperature.

Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT

Displays the time, day and schedule 
MORNING, DAYTIME, EVENING
or NIGHT

MENU 

Key Displays 

the User options.

MODE

 Key Selects

Thermostat Mode
HOLD, SCHEDULE or VACANT

Displays the upstairs airflow

Displays the Airflow Mode
AUTOMATIC or MANUAL

Displays the heating or 
cooling temperature

FAN MODE

 Key

AUTO or ON

Warranty

This thermostat is warranted to be free of defects due to 
workmanship or materials under normal use and service for a 
period of 5 years from date of installation and not longer than 
6 years from manufacturing date code.

Installer Manual

Model C365T21 and C365T21WF

365

Comfort

eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653

949-916-0945 Fax 949-458-8502 www.eControlsUSA.com

eControls

eControls

Ver1.8 / Ver2.2_1.0.4 Aug 2017

Displays the downstairs airflow

NEXT 

Key 

Used to advance through
options

ENTER 

Key 

Used to save options and 
return to thermostat operation

i

To disable airflow control so the thermostat operates 
as a typical thermostat, use Option 17 to turn airflow 
control off. The thermostat will control the system as 
any other thermostat and the nighttime airflow option 
will be disabled.

i

The C365 thermostat controls heating, cooling and airflow to 
the upstairs and downstairs using an upstairs and a downstairs 
modulating damper.  A temperature sensor located upstairs 
monitors the upstairs temperature and the temperature sensor 
in the C365 monitors the downstairs temperature.  

The C365 adjusts the upstairs and downstairs airflow during 
heating and cooling calls to maintain uniform upstairs and 
downstairs temperatures.  

SYSTEM MODES

  Off, Heat, Cool, Auto

THERMOSTAT MODES 

 Hold, Schedule or Vacant mode.

PROGRAMS PER DAY

  Morning, Daytime, Evening and Night.

PROGRAM FORMAT

  Weekdays and weekend– 5/2.

TEMPERATURE OVERRIDE

  Temperature is held for 4 hours 

when adjusted in Schedule mode. 

FAN MODES

  Auto or Continuous 

AIRFLOW CONTROL

  Airflow can be turned off using Option 

15. Dampers fully open, nighttime airflow options are disabled 
and airflow is no longer displayed on the thermostat.

AIRFLOW LIMITS

  Maximum upstairs and downstairs, heating 

and cooling airflow limits can be set during installation.

NIGHTTIME OPERATION

  The C365 thermostat uses the 

upstairs temperature sensor to control heating and cooling 
calls and directs more airflow upstairs. If bedrooms are located 
downstairs, the Nighttime Airflow option should be turned off.

COMPATIBLE EQUIPMENT

  Gas/electric equipment with 2-

stage heating and 1 stage cooling or 1 stage heating and 2-
stage cooling and heat pumps with 2-stage heating and 2-
stage cooling.

UPSTAIRS TEMPERATURE SENSOR

  One TS510W sensor 

or two TS520W upstairs temperature sensors can be used.

MODULATING DAMPERS

  Round or rectangular dampers 

using the A80MT actuator and up to 1 inch static pressure.

POWER

  Operates on 24VAC from the HVAC equipment using 

the R and C wires.

ATTENTION INSTALLER

i

Nighttime Airflow Option. If bedrooms are located
downstairs, the Nighttime Airflow Option should be 
turned OFF using the User Options.

i

Set Options (p.5-7). Options 1 through 5 determine the
equipment operation and must be set if different than
Factory Settings.

After installing and wiring dampers and sensors to the 
thermostat, CHECK FOR ERROR MESSAGES (p.4)

Set time of day (p.4)

i

Description

Summary of Contents for C365T21

Page 1: ...he C365 monitors the downstairs temperature The C365 adjusts the upstairs and downstairs airflow during heating and cooling calls to maintain uniform upstairs and downstairs temperatures SYSTEM MODES Off Heat Cool Auto THERMOSTAT MODES Hold Schedule or Vacant mode PROGRAMS PER DAY Morning Daytime Evening and Night PROGRAM FORMAT Weekdays and weekend 5 2 TEMPERATURE OVERRIDE Temperature is held for...

Page 2: ...uired to define the upstairs or downstairs zones the damper may be wired in parallel LEDS on the damper actuator indicate when the damper is fully open green or fully closed red Green LED Red LED INSTALL UPSTAIRS DOWNSTAIRS DAMPERS R C WOB EQUIPMENT Y G Upstairs Sensor COM COM CLS CLS OPN OPN Upstairs Downstairs Upstairs Sensor W2E Y2 C365T21 Ensure that damper installation does not cause obstruct...

Page 3: ...C365T21 Downstairs Thermostat Model TS5 Upstairs Temperature Sensor Model R80CT XX Downstairs Damper Y Y W O or B C C R R WIRING DIAGRAM C365T21 Upstairs Sensor WIRING INSTRUCTIONS Cont Use 3 conductor 18 or 20 gage thermostat cable to wire from the C365 Thermostat to the upstairs and downstairs dampers There are separate terminals for the upstairs and the downstairs dampers Multiple dampers can b...

Page 4: ...n to thermostat operation CHANGE THE DAY OF THE WEEK Inside Tu Day Upstairs Auto Downstairs Airflow COOL Schedule AUTO FAN MENU MODE Cool Set To SYSTEM AM Touch here to change the time and day of the week We ENTER AM NEXT ENTER AM Press the touchscreen with your fingertip only using a firm touch Do not use a sharp object such as a pen or pencil Inside Tu Day Upstairs Auto Downstairs Airflow COOL S...

Page 5: ...cription Equipment Type Reversing Valve Compressor Stages Compressor Minimum Off Time minutes Gas Minimum Off Time minutes Minimum Run Time minutes On Off Temperature Differential Smart Recovery Vacant Heating Setpoint Vacant Cooling Setpoint o o 0 Cooling On 1 above setpoint Off at setpoint Heating On1 below setpoint Off at setpoint o o o o 1 Cooling On 1 above setpoint Off 5 below setpoint Heati...

Page 6: ...NEXT ENTER Touch the keys to set the time in minutes to update the upstairs and downstairs airflow Touch or UP DOWN NEXT ENTER Option NEXT ENTER This is the frequency in minutes that the damper position is updated 14 Calibrate Upstairs Temperature Sensor Factory Default None o Range 5 15 Airflow Update Time Factory Default 2 Minutes Range 1 to 20 Minutes Touch the UP DOWN keys to change the minimu...

Page 7: ... Airflow in Cooling Factory Default 140 Range 100 to 160 22 Maximum Downstairs Airflow in Heating Factory Default 150 Range 100 to 160 23 Maximum Downstairs Airflow in Cooling Factory Default 140 Range 100 to 160 24 Maximum Temperature Differential Factory Default 2 F o Range 0 to 10 F o o 25 Factory Restore WARNING Factory Restore resets ALL settings WiFi model only When participating in Demand S...

Page 8: ... is too great and causes noise or annoyance Increase the airflow using the key until it is acceptable This is the maximum allowable downstairs airflow in heating Record the airflow value DOWN UP Maximum Allowable Downstairs Airflow in Heating 05 06 Testing Cooling Airflow Limits In Option 5 the system is Off Touch to go to Option 6 to activate cooling Verify the equipment is operating To determine...