Time -Del. Emergency Stop Safety Relay SR4C 

M11 

Ver. A 

E61-140-00 

Operating Instructions

 

English translation 

Errors and technical changes reserved 

• 

Cyclical monitoring of the output contacts

 

• 

Indication of the switching state via LED

 

• 

2 start behaviors possible:

 

    

-

 monitored manual start

 

    

-

 automatic start

 

• 

Short circuit and earth fault monitoring

 

• 

Up to PL e, SILCL 3, category 4

 

SR4C  is  an  emergency  stop  safety  relay  combination  that     
combines non-time-delayed and time-delayed contacts in a very 
compact  housing.  This  permits  dangerous  components  of  a 
system  to  be  switched  off  quickly  and  safely  in  an  emergency 
situation.  At  the  same  time,  other  circuits  can  continue  to  be 
supplied with voltage for up to 30 seconds to allow a tool to be 
moved  to  its  idle  position  or  to  brake  following  parts,  for     
example. 

• 

4 positively driven safety relays contacts. Possible vari-
ants:

 

    

-

 3 non

-

time

-

delayed and 1 time

-

delayed contact

 

    

-

 2 non

-

time

-

delayed and  2 time

-

delayed contact

 

    

-

 1 non

-

time

-

delayed and  3 time

-

delayed contact

 

• 

Continuously adjustable time delay (1 to 30s).

 

• 

Connection of:

 

    

-

 Emergency stop buttons

 

    

-

 Safety switches

 

    

-

 Non

-

contacts safety switches

 

    

-

 OSSD

-

Outputs

 

• 

1

-

 or 2

-

channel activation possible

 

• 

Feedback loop for monitoring downstream contactors or 
expansion modules

 

Function

 

The  moving  parts  of  a  machine  or  system  can  be  quickly 
and  safely  stopped  in  case  of  danger  with  the  non

-

time

-

delayed  contacts  of  the  SR4C  Safety  contacts  with  time

-

delay  switch

-

off  are  also  integrated  into  the  SR4C.  They 

are used  whenever it is safer to keep  supplying voltage to 
parts  of  a  machine  after  the  emergency  stop  switch  is 
operated.

 

It is ensured that a single fault or malfunction does not lead 

Installation

 

As per DIN EN 60204

-

1, the device is intended for installa-

tion in control cabinets with a minimum degree of protection 
of IP54. It is mounted on a 35 mm DIN rail according to DIN 
EN 60715 TH35.

 

Safety 

 

Precautions

 

Fig. 2  Installation/removal 

to a loss of the safety function and that every fault is detect-
ed by cyclical self

-

monitoring no later than when the system 

is switched off and switched on again.

 

The  time

-

delay  contacts  are  activated  at  the  same  time  as 

the non

-

time

-

delay contacts; however, when the emergency 

stop  button  is  pressed,  the  contacts  are  only  deactivated 
after the time set on the potentiometer (1 … 30s).

 

During timeout, no power

-

loss is accepted.

 

Electrical 

 

Connection

 

• 

Consider the information in the section "Techn. data"

 

• 

A safe transformer according to EN 61558

-

2

-

6 or a 

power supply unit with electrical isolation from the mains 
must be connected

 

• 

External fusing of the safety contacts must be provided

 

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty

 

• 

Use adequate protective circuit for inductive loads (e.g. 
free

-

wheeling diode)

 

Fig. 3  Connections 

nd = non-time delayed; d = time-delayed 

Fig. 1 Block diagram:                            SR4C (1nd/3d);                                                                           SR4C (2nd/2d);                                                                           SR4C (3nd/1d) 

A1: 

 

 

Power supply

 

A2 :

 

 

Power supply

 

S11: 

 

 

DC 24 V control voltage

 

S10: 

 

 

Control line 

 

S12:

 

 

Control line

 

S13:

 

 

Control line

 

S14:

 

 

Control line

 

S21:

 

 

Start control line

 

13

-

14:

 

 

Safety contact 1 (nd)

 

23

-

24/27

-

28:

 

Safety contact 2 (d / nd)

 

33

-

34/37

-

38:

 

Safety contact 3 (d / nd)

 

47

-

48:

 

 

Safety contact 4 (d)

 

 

• 

All relevant safety regulations and standards are to be 
observed.

 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user.

 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage.

 

• 

Note down the version of the product (see label “Ver: x”) 
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of 
the control system in which the device is incorporated 
must be validated again by the user.

 

• 

Installation and commissioning of the device must be 
performed 

only by authorized personnel

.

 

• 

Observe the country

-

specific regulations when installing 

the device.

 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated.

 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost.

 

• 

It is not allowed to open the device, tamper with the 
device or bypass the safety devices.

 