background image

DSR-400

Operation Manual

YCO-1105-06-02

YAMATO CORPORATION

1775 S. Murray Blvd.
Colorado Springs, CO  80916   USA
Tel (719) 591-1500  Fax (719) 591-1045

YAMATO TECH CORPORATION

#112-19425 Langley By-Pass
Surrey, B.C.  V3S 6K1     Canada
Tel (604) 533-2338  Fax (604) 533-0827

Summary of Contents for DSR-400

Page 1: ...YCO 1105 06 02 YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 ...

Page 2: ...1 Do not push the indicator or keys with sharp objects They may break or puncture the switch membrane panel 2 Use the specified power supply and choose a suitable environment If you do not the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the platform or drop it the scal...

Page 3: ...ires six AA size batteries or AC input when using the AC adaptor Operating temperature 32 F to 104 F 0 C to 40 C III Operation III A Control Panel 1 LCD Display Displays weight reading and error messages 2 Unit Selection Key Press to toggle between lb kg indications 3 Net Gross Key Press to toggle between Net Gross weight 4 ON ZERO Key Turns the power on and zeroes the display TARE Tares off the w...

Page 4: ...capability The current mode of the scale is indicated by the arrow heads in the LCD display To toggle between the two modes press the lb kg key III C Turning the Scale On and Off Remove everything from the platform surface and press the ON O T key The display will briefly display four eights After approximately three seconds the display will automati cally set to zero Press lb kg N G keys simultan...

Page 5: ...sic Weighing 1 Begin with no load on the scale and the display reading zero 2 Place an empty container on the scale platform wait for the indication to stabilize and press the ON O T key The weight of the container will automatically be deducted the display will read zero 3 Place the item s to be weighed in the container The weight displayed will be the net weight 4 To toggle between the net and g...

Page 6: ...tinues to show all 8s after the scale is turned on The scale will not power on The keyboard does not func tion The displayed weight fluctuates excessively Possible Cause Vibration or an unstable position or platform AC adapter malfunction Power board malfunction CPU board malfunction Keyboard connector loose Keyboard connector damaged Keyboard damaged CPU board malfunction Weighing assembly in con...