background image

www.westermo.com

WeOS

Lynx DSS 

L-106-S2 EX / L-206-S2 EX

Industrial Ethernet  
6-port Device Server Switch

Summary of Contents for Lynx DSS L106-S2 EX

Page 1: ...www westermo com WeOS Lynx DSS L 106 S2 EX L 206 S2 EX Industrial Ethernet 6 port Device Server Switch ...

Page 2: ...2 6643 22901 ...

Page 3: ...nternet address www westermo com Software tools Related software tools are available in the folder software tools under technical support on the Westermo website License and copyright for included Free Libre Open Source Software This product includes software developed by third parties including Free Libre Open Source Software FLOSS The specific license terms and copyright associated with the soft...

Page 4: ...ated at an ambient temperature above 55 C 131 F the External Surface of Equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord For more information see General safety 100 5001 Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warrant...

Page 5: ...treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring this product is disposed of correctly you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health which could be caused by inappropriate disposal ...

Page 6: ...e relevant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non hazardous or the circuits connected have been de energized The network cables once installed must be properly fixated by the use of cable ties or similar to ...

Page 7: ... und EN 60079 15 erfüllt installiert werden Alle äußeren Anschlüsse des Gerätes und auch die SFP Module dürfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Gerät installiert ist nachweislich ungefährlich ist oder die verbundenen Stromkreise spannungsfrei sind Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material ordnungsgem...

Page 8: ...N 60079 0 et EN 60079 15 Toutes les connexions externes à l équipement et le cas échéant les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l équipement est installé est reconnue comme non dangereuse ou si les circuits raccordés sont hors tension Une fois les câbles réseau installés ils doivent être correctement fixé grâce à des attaches de câbles ou autre élément...

Page 9: ...ructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re...

Page 10: ...s 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission for residential environments 2007 A1 2011 EN 61000 6 4 Electromagnetic compatibility Emission for industrial environments 2007 A1 2011 EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and telecommunicati...

Page 11: ... L E 2 kV 42 Ω 0 5 μF L L 1 kV 42 Ω 0 5 μF RS 232 L E 2 kV 2 Ω 0 5 μF RS 422 485 L E 2 kV 42 Ω 0 5 μF Power frequency magnetic field EN 61000 4 8 Enclosure 300 A m 0 16 7 60 Hz 1000 A m 50 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 2700 MHz 10 V m 2700 6000 MHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 ...

Page 12: ...TBF MIL C217F2 Parts count Ground Benign 25 C 77 F 593 000 hours Service life Operating 10 year Vibration IEC 60068 2 6 sine Operating 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g IEC 60068 2 64 random 5 20 Hz 2 m s 20 2000 Hz 3 dB oct Shock IEC 60068 2 27 Operating 30 g 11 ms 100 g 6 ms Bump IEC 60068 2 27 Operating 10 g 11 ms Packaging Enclosure EN 60950 1 Zin...

Page 13: ...SS L106 S2 EX L206 S2 EX has two serial ports one that supports RS 232 and the other configurable for RS 232 422 485 as well as serial protocols for interconnection with legacy equipment Our unique FRNT Fast Recovery of Network Topology technology is the fastest protocol on the market to re configure a network in the event of any link or hardware failure That is why our equipement are used in safe...

Page 14: ...ctor cross section 0 2 2 5 mm2 AWG 24 12 Stripping length cable 7 mm Tightening torque terminal screw 0 5 0 6 Nm Tightening torque screw flange 0 3 Nm Shielded cable Not required External supply current capability for proper start up Ethernet TX Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type TNV 1 T...

Page 15: ...V 1 Transmission range RS 232 15 m 49 ft RS 422 485 Up to 1200 m 0 74 mi depending on data rate and cable type Isolation to All other Connection RS 232 RJ 45 according to EIA 561 RS 422 485 RJ 45 Shielded cable RS 232 Recommended RS 422 485 Not required but recommended in railway installations close to the rails Conductive housing Yes Number of ports 1 To minimise the risk of interference a shield...

Page 16: ...rque terminal screw 0 22 0 25 Nm Tightening torque screw flange 0 3 Nm USB Electrical specification USB 2 0 host interface Data rate Up to 12 Mbit s full speed mode Circuit type SELV Maximum supply current 500 mA Connection USB receptacle connector type A Console Electrical specification LVTTL LVCMOS level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit ...

Page 17: ...port U 1 V 4V μs I 20 mA Data rate 10 100 Mbit s No 2 TD In Out Transmitted Received data No 3 RD In Out Transmitted Received data No 4 Not Connected No 5 Not Connected No 6 RD In Out Transmitted Received data No 7 Not Connected No 8 Not Connected Shield Connected to PE Galvanically isolated via signal transformers and capacitively isolated to GND PE through a 2kV 1000pF capacitor See user manual ...

Page 18: ...eceive U 5 V max I 250 mA max Data rate 50 bit s 2 Mbit s No 2 T T R Out In RS 422 Transmit RS 485 Transmit Receive No 3 R In RS 422 Receive No 4 Not used No 5 Not used No 6 R In RS 422 Receive No 7 Not used No 8 Not used Lynx DSS is equipped with internal termination that is configurable through software in RS 422 485 mode The following termination schemes are supported RS 422 No termination Rx T...

Page 19: ...port if drivers are needed they can be downloaded from ourWeb page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information about the CLI see theWeOS management guide I O connection for details see page 15 Console port for details see page 15 Cable 1211 2027 Bottom view Accessories Description Art no Westermo console cable 1211 2027 R...

Page 20: ... Alarm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events within the Lynx unit see WeOS Management Guide An external load in series with an external voltage source is required for p...

Page 21: ...No voltage present on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch USR1 OFF Configurable see WeOS Management Guide GREEN RED Rx TD TD OFF No serial data received GREEN FLASH Serial data received Tx RD RD OFF No serial data transmitted GREEN FLASH Serial data tra...

Page 22: ...ated DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life 10mm 10mm Removing Lynx with integrated DIN clip Press down the support at ...

Page 23: ...mentation is available in the chapter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via Web browser The unit can easily be configured via a Web browser Open the link http 192 168 2 200 in your w...

Page 24: ...ctory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and the unit will restart with factory default settings When the switch has booted up the ON LE...

Page 25: ...25 6643 22901 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 ...

Page 26: ......

Page 27: ......

Page 28: ...REV G 6643 22901 2019 08 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...

Reviews: