Wave MiniBOSS MEPC 107(49)

110 / 240v AC

24v DC

Monitored Oil Removal System

OPERATION & MAINTENANCE MANUAL

Tel: +44 1476 861717

[email protected]

www.waveinternational.co.uk

Summary of Contents for MiniBOSS

Page 1: ...Wave MiniBOSS MEPC 107 49 110 240v AC 24v DC Monitored Oil Removal System OPERATION MAINTENANCE MANUAL Tel 44 1476 861717 info waveinternational co uk www waveinternational co uk...

Page 2: ...of the OCM 6 2 4 Changing the OCM Alarm Limit 6 2 5 Special tools 6 2 6 Shutdown procedures 6 2 7 Pre screening 7 3 MAINTENANCE 7 3 1 Component Maintenance 7 4 TROUBLE SHOOTING 8 4 1 Reduced flow thr...

Page 3: ...gm pump The design capacity of the standard MiniBOSS system is 1 gpm 0 25 M3 hr at 25 psig back pressure and no vacuum on the inlet or 1 5 gpm 0 35 M3 hr with the MiniBOSS 110 However the actual flow...

Page 4: ...s 83 lbs Capacity max 1 gpm 0 25 M3 hr 1 5 gpm 0 35 M3 hr Filter Media XP420 Extreme XP420 Extreme Test PSIG 55 55 Operating Pressure Up to 50 PSIG Up to 50 PSIG Operating Temp Range 1 55 C 1 55 C Oil...

Page 5: ...arm and Action Conditions The only alarm condition that requires operator action is when the oil removal filters have reached maximum hydrocarbon saturation This is determined by the inability of the...

Page 6: ...ither from your distributor or the factory to verify the calibration of the monitor It is not necessary to test the calibration as long as the cell has a valid calibration certificate The instructions...

Page 7: ...nent The only exception to this is the oil content monitor which is the most expensive component on the system In the case of the oil content monitor it is against IMO regulations for the customer to...

Page 8: ...of communication between the display and the detector loose cable c internal board or power supply failure See separate OCM O M manual for a more detailed explanation of the OCM 4 3 Solenoid Valve not...

Page 9: ...AKER 1P 2A C CURVE 41070 24V 110V GAUGE PRESSURE 100PSI BAR BRASS STEM GLYCOL 40371 24V 110V Measuring Cell Sensor for BilgMon 488 TPH 488MC 40456 24V 110V Cleaning Brush for BilgMon 488 Measuring Cel...