6300 Surface Mounted Rim Strike

Important: 

The New 6300

 

Electric Strike is never to be used as a door stop. Please install stops on frame 

in appropriate locations. Ensure the exit device functions as intended for life safety concerns by verifying  
electric strike and exit device compatibility. Maximum latch projection is essential to obtain full holding force.

When installed in a fail secure manner, the local Authority Having Jurisdiction shall be consulted with regard 
to the use of selected panic hardware to ensure emergency exit from the secured area.  

Catalog Specifications 

 

Model

Mode

Voltage

Current

Duty

Amps

Ohms

6300

Fail Secure

12V

DC

Continuous

0.50

22

6300

Fail Secure

24V

DC

Continuous

0.24

89

Fail Locked = Fail Secure = FSE   DC = Direct Current    
Continuous Duty = Energized 1 minute or more 

Dimensional Details

3/4"

(19.0mm)

1-5/8"

(42.0mm)

9"

(228.6mm)

8-1/4"

(209.6mm)

1-3/4"

(44.5mm)

5-1/2"

(139.7mm)

HORIZONTAL
ADJUSTMENT
MOUNTING 
HOLES 

LOCK DOWN

HOLES