Page 1: ...Installer manual 02907 Wi Fi touchscreen thermostat CLIMA ...

Page 2: ... between the device and the authorized applications for the remote control function as well as signals for verifying correct access and operation of these services and devic es The above information is all necessary and functional in order to enable correctly performing the functions of remote control and maintenance of the applications and devices supported by the platform The ID of the device an...

Page 3: ...ay 18 7 1 Functions of the buttons 19 7 2 Symbols 19 7 3 Standby 20 7 4 Locking the interface via PIN 20 7 5 Viewing the display 21 8 Operating mode 22 8 1 Switched off OFF 22 8 2 Manual 23 8 3 Auto 24 8 4 Timed manual 24 8 5 Away 26 8 6 Antifreeze 27 9 Settings menu 27 9 1 Operating mode setting 28 9 2 Standby brightness level setting 28 9 3 WiFi setting 28 9 4 Info about the device 30 10 Paramet...

Page 4: ...2 ...

Page 5: ... heating or on the control circuit of the air conditioner air conditioning ensuring an ideal temperature The graphical user interface thanks to special views facilitates system management helping the user to oper ate while maintaining a state of energy saving 3 Installation The appliance must be installed on a wall at a height of 1 5 m off the floor in a suitable position for correctly detecting t...

Page 6: ...O 6 mm V I M A R SpA e2 Pb MA DE IN ITA LY T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm V I M A R SpA e2 Pb MA DE IN ITA LY T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm V I M A R SpA V I M A R SpA e2 Pb MA DE IN ITA LY T40 5 2 A 230V 230V 50 60Hz 1 C C N L NC NO 6 mm 2 click 1 ...

Page 7: ...5 4 Connections 4 1 Relay connection L N U1 N T C V I M A R SpA C NCNO N L Fig 1 Circulation pumps burners solenoid valves L N N T C U1 V I M A R SpA C NCNO N L Fig 2 Motorized valves Connections ...

Page 8: ...terminals without any par ticular order It is recommended to use the NTC 10k beta 3900 probe art 02965 1 20432 19432 14432 The typical wiring diagram is the following art 02965 N T C V I M A R SpA e2 Pb C NCNO N L V I M A R SpA e2 Pb C NCNO N L art 20432 art 19432 art 14432 Fig 3 Connecting the external temperature probe 4 2 1 Installation examples 02965 1 used to display the outside temperature C...

Page 9: ...sed for limiting the temperature of underfloor heating IMPORTANT During installation take care not to damage the insulation of the probe while laying the screed Perform the installation in such a way that the probe is accessible for any maintenance work Connections ...

Page 10: ...ay where you can reset the device parameters Fig 5 Parameter reset screen By confirming with ALL the device parameters temperature setpoint heating air conditioning mode unit of measurement etc and ALL WiFi function settings phone numbers SMS etc will be restored to the default values WARNING This operation is not undoable If you wish to reset only the WiFi settings refer to paragraph 9 3 Switchin...

Page 11: ...ation make sure the Gateway Router has been turned on for at least 2 minutes and is connected to the Internet Make sure the thermostat is installed at a reasonable distance from the router where the signal is strong enough Activate configuration mode in this phase the thermostat acts as an access point generating a specific temporary WiFi network for the configuration with no need for an Internet ...

Page 12: ...pping ON or OFF will begin to flash Using and select ON and confirm by tapping 5 Using and scroll through the list of options until you see the Conf screen 6 Confirm by touching 7 The display will show Strt Configuration via WiFi interface ...

Page 13: ... tapping b closing the By clima App c when the mobile device e g smartphone goes into standby 6 1 2 Configuring the thermostat with the By clima App Pick up the mobile device on which is installed the By clima App updated to the latest version Stand in front of the thermostat On the device enable the WiFi interface and scan for available networks Connect the mobile device to the WiFi network gener...

Page 14: ...7 and a variable portion of 6 hexadecimal characters indicating the serial number of the device you want to configure see the example in figures 6 and 7 1 Launch the By clima App on the mobile device 2 Add a new device by tapping Fig 6 Back of the thermostat 02907 Fig 7 Network selection screen on smartphone Configuration via WiFi interface ...

Page 15: ...Select 02907 Thermo WiFi 4 Select the Configure a new Thermostat procedure Fig 8 By clima App for an empty database Fig 9 By clima App for a database in which there is at least one device Quale operazione vuoi effettuare Sostituire un CronoTermostato Configurare un nuovo CronoTermostato Collegarsi ad un CronoTermostato attivo SC02 Giovedì 19 Dicembre 2013 Casa I tuoi dispositivi Fig 10 By clima App...

Page 16: ...ltre di modificare il PIN di rete per limitare l accesso al tuo Cronotermostato 0000 Inserisci ora il PIN di accesso di rete per proseguire con la configurazione Il valore di default del PIN è 1234 Come vuoi procedere Configurare i parametri di accesso alla rete Concludere la configurazione to proceed with the guided configuration and follow the instructions displayed directly by the App Fig 11 By cli...

Page 17: ...k and cloud services The network parameters should be configured during initial installation and or if you change the network cre dentials with which the thermostat connects to your home WiFi Using the By clima App you enter the section shown in the figure on the next page and proceed by entering the parameters with which the thermostat will connect to your home WiFi network network name password ...

Page 18: ...are Saving all the thermostat settings should you need to replace it Registration with the Vimar cloud is automatic and is linked to the thermostat creating a user is not required no login By pairing a mobile device with the thermostat the smartphone tablet is merged at the logic level with the registration of the thermostat in the cloud see par 6 2 6 3 2 Use without the cloud If you do not wish t...

Page 19: ...the mobile device is paired with the thermostat the PIN code of the mobile device and that of the thermostat coincide If you change the PIN of the thermostat but not that of the tablet smartphone the mobile device which is still set to the old PIN will no longer be able to manage the thermostat it will then be necessary to update the PIN of the tablet smartphone device s CAUTION The PIN for access...

Page 20: ...ng the following buttons and icons Fig 14 Graphical interface and buttons A WiFi radio signal strength indicator B Operating mode C Away D Confirm E F Menu navigation and setting parameters G Back H Settings menu I AUTO programme temperature trends I H G F E D C B A Display ...

Page 21: ...ctivates the submenu if there is one or displays the next parameter digit After each confirmation the display shows the icon for approximately 1 s back or cancel exits the current screen menu and returns to the previous one without saving any changes In menus with changes to multiple digits it lets you go back to change the previous digit N B The field value being edited is highlighted by the fiel...

Page 22: ...e device 7 4 Locking the interface via PIN set by the App The thermostat lets you set a password which inhibits any change to the operating mode eg switching from Manual to OFF limits setting the temperature values and more generally blocks access to the configuration menu This feature is useful to prevent the thermostat being used by unauthorized persons the device prompts you to enter the PIN in...

Page 23: ...away equivalent to T economy equivalent to T comfort The clock shows the current time The indicator of the day of the week highlights the current day with a dash under the number associ ated with it eg 4 Thursday The set temperature indicator highlights the current temperature being regulated thus replicating the information represented by the dashes T away T economy T comfort The energy saving in...

Page 24: ...iod of time at the end of which the device will return to AUTO mode Away lets you set the set point in order to achieve significant energy savings during periods when the user is away Antifreeze used to set a minimum temperature level to avoid damage to pipework or prevent the temper ature from falling below a safety level The operating mode is selected via the SETTINGS menu or with the shortcut k...

Page 25: ...he icon is displayed above the temperature indicator Fig 18 Typical screen for Manual mode The set point can always be changed via or Fig 19 Manual set point setting The selection is confirmed by touching The and icons in the lower right corner indicate whether the system is operating in heating or air conditioning mode respectively icon illuminated system on Operating mode ...

Page 26: ...emporarily change the ambient temperature setting it to a differ ent value to the one associated with the current time slot Confirming with it then goes into TIMED MANUAL mode The and icons in the lower right corner indicate whether the system is operating in heating or air conditioning mode respectively icon illuminated system on 8 4 Timed manual This mode allows you to exit the AUTO program you ...

Page 27: ...xt screen again using and lets you set the time for which the temperature you have just set is maintained Fig 22 Regulating the number of hours of Timed Manual mode Finally confirm with At the end of the set time the thermostat goes back into AUTO mode the icon switches off and reappears Operating mode ...

Page 28: ...tment according to the away temperature setpoint The Away mode can only be activated by touching The display will show the away temperature setpoint for approximately 2 seconds Fig 23 Input in away mode showing the away temperature Mode activation is identified by the icon Fig 24 Away Mode To exit and return to the initial mode touch the button again Operating mode ...

Page 29: ...s identified by the icon above the temperature indicator Fig 25 Antifreeze mode 9 Settings menu From the settings menu you can configure all the features of the thermostat On the main screen tap the icon From the main menu using and will display the following flashing symbols in succession which provide access to the corresponding submenus 1 operating mode setting 2 setting WiFi functionality 3 se...

Page 30: ...9 3 1 On Off The menu lets you turn the WiFi module on or off completely if it is turned off in addition to eliminating any wireless transmission reception of the device some of the following submenus are inhibited Using and select ON or OFF and confirm with 9 3 2 Enable Cloud Service The menu lets you select whether or not to take advantage of the cloud service offered by Vimar If you do not inte...

Page 31: ... both the smartphone tablet and on the thermostat at the same time this ensures that the device can not be controlled by undesired users who have not performed the pairing phase Touch and then to start the pairing procedure then follow the instructions displayed directly on your smartphone tablet 9 3 6 WiFi Info 9 3 6 1 WiFi FW version The menu lets you view the version of the firmware for the WiF...

Page 32: ... to learn about the latest software version available for your device if your device can be upgraded the icon will be blinking alongside the new SW version Tap to start the update from the Vimar cloud and wait until the next time the thermostat is restarted Caution While updating the SW do not turn off the device nor access the thermostat with the By clima app 10 Parameters table Function Paramete...

Page 33: ...on 10 35 C 0 1 C 27 C T2 Comfort Aircon 10 35 C 0 1 C 25 C TM Manual Heat 10 35 C 0 1 C 18 C TM Manual Aircon 10 35 C 0 1 C 26 C TG Antifreeze 4 10 C 0 1 C 5 C Programs Heating Prog T0 T1 T2 Heating for each interval of time 24hx4x7d Air Con Prog T0 T1 T2 Air con for each interval of time 24hx4x7d WiFi Radio On ON OFF ON Cloud Enable cloud ON OFF ON Clock synchronization Enable synchroniza tion vi...

Page 34: ...ring the cleaning phase Avoid using aggressive products Clean the display with a special cloth for cleaning lenses 13 Features Rated supply voltage 230 V 50 60Hz Max power drawn from the grid 3 VA Operating temperature range 0 40 C T40 Temp measurement accuracy built in probe 0 5 C between 15 C and 30 C 0 8 C at the ends Relay output with clean change over contacts 5 2 A 230 V Terminals Relay C Re...

Page 35: ...is type of security system you should modify it with WPA or WPA2 See paragraph 12 note 2 IP communication protocol on which the entire Internet network is based IP Address the address that every device must have in order to communicate with other devices via the IP protocol It consists of four numbers separated by periods e g 192 168 0 123 Subnet mask useful for devices that direct IP traffic indi...

Page 36: ...ostat Serial number 17 2 WiFi Router Main router of the installation site Brand Model Notes 17 3 Additional Access Point If there is an additional device that extends the WiFi coverage inside the home site Brand Model Notes Appendix 1 Data on the WiFi network ...

Page 37: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 02907IEN 01 1806 ...