background image

Replacing a cooling module in a 5U84 Storage Shelf

Document Number: 228

Version 1.1 (03/05/18)

Purpose

This document describes the process for replacing a cooling module in the 5U84 Storage Shelf.

Electrical Safety

The static discharged by human bodies can damage static-sensitive components on the boards.

When installing and maintaining the equipment, observe appropriate electrostatic safety precautions

to prevent personnel injuries or device damage.

When operating a device in an electrostatic sensitive area, you must take electrostatic-discharge

(ESD)-preventive measures. These include wearing ESD-preventive gloves, an ESD-preventive wrist

strap, and ESD-preventive clothes to avoid personnel injury or device damage.

To prevent damage to the device, pay attention to the following during operations:

Do not touch devices with bare hands because ESD from the human body may damage the

electrostatically sensitive elements on a board.

When dealing with the server or any of the internal components, wear an ESD-preventive wrist

strap, ESD-preventive gloves, and ESD-preventive suit.

High availability (HA) appliance service considerations

Attention:

A HA or multi-node appliance is serviced in the same manner as a single node appliance.

About the hot swappable 5U84 Storage Shelf cooling modules

The Veritas 5U84 Storage Shelves include five cooling modules and they are hot swappable. The

cooling modules provide cooling to the entire unit, which is suitable to maintain the internal component

temperatures below each components maximum temperature limits.

1

Veritas Appliance

Hardware Service Procedure

Summary of Contents for 5U84

Page 1: ...ury or device damage To prevent damage to the device pay attention to the following during operations Do not touch devices with bare hands because ESD from the human body may damage the electrostatically sensitive elements on a board When dealing with the server or any of the internal components wear an ESD preventive wrist strap ESD preventive gloves and ESD preventive suit High availability HA a...

Page 2: ...t strap or take other ESD protective measures Caution You must complete a cooling module swap within three minutes Leaving the slot open for longer than three minutes can result in the 5U84 Storage Shelf overheating and causing other components to fail Caution Operation of the enclosure with any modules missing will disrupt the airflow and the disk drives will not receive sufficient cooling It is ...

Page 3: ... Example of a faulty cooling module with an LED that is not lit 3 Grasp the faulty cooling module handle and depress the retaining latch 3 HSP 228 Replacing a 5U84 Storage Shelf cooling module ...

Page 4: ...uilt in handle and pull the cooling module out to remove the module from the 5U84 storage shelf 5 Place the faulty cooling module in an ESD preventative bag 4 HSP 228 Replacing a 5U84 Storage Shelf cooling module ...

Page 5: ...e replacement cooling module from its packaging 3 Orient the replacement cooling module so that the black and orange release latch is on the right side of the module 4 Slide the replacement cooling module completely into the storage shelf A click should be heard as the retaining latch engages 5 Monitor the cooling module LEDs for any faults Verify that the LED on the replacement module is green an...