background image

Accolade

INSTALLER’S AND OWNER’S GUIDE

For

Electric Heater

Model 806

We trust that this Guide gives sufficient details to enable the appliance to be installed and

maintained satisfactorily. However, if further information is required, our 

Valor

Technical Helpline

 will be pleased to help.

Please telephone 08706 061 065 

(National call rates apply in the United Kingdom).

KEEP IN A SAFE PLACE FOR FUTURE REFERENCE

© 

Valor Heating

3002911/04

Summary of Contents for accolade 806

Page 1: ...ils to enable the appliance to be installed and maintained satisfactorily However if further information is required our Valor Technical Helpline will be pleased to help Please telephone 08706 061 065...

Page 2: ...ed adjacent to but not above the heater Always disconnect the heater from the electrical supply before carrying out cleaning maintenance or replacing lamps Always make sure the heater is firmly fixed...

Page 3: ...lace openings or in a wooden surround where the following dimensions are available Width 390 450mm Height 555 590mm Depth At least 75mm Alternatively the heater can be fitted to a flat wall or surroun...

Page 4: ...ying the terminals in your plug fit the wires as follows The wire which is coloured Green Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol...

Page 5: ...separate the front surround from the heater Keep the front surround in a safe place when installing the fire Offer the heater body to the fireplace opening to ensure that it will fit before continuin...

Page 6: ...two holes in the top flange passing the wire through the eyebolt and out through one of the opposite holes on the top flange See figure 4 Locate the heater into the fireplace opening then by gently pu...

Page 7: ...in the marked position Take care not to drill right through the spacer frame Screw the brackets to the spacer frame Place the spacer frame in the desired position against the wall Mark the fixing posi...

Page 8: ...containing the loose glass pebbles and place them on the fuel support to give the most pleasing effect It is not necessary to use all the glass pebbles supplied IMPORTANT The glass pebbles are for dec...

Page 9: ...e heating element to prevent damage due to over heating If it operates due to an obstruction in the airflow the heater must be turned off unplugged from the mains socket and allowed to cool for 15 min...

Page 10: ...me The fault problem or request Serial Number This is located behind the fire front surround USEFULL TELEPHONE NUMBERS General advice about gas and your gas fire VALOR TECHNICAL HELPLINE 08706 061 065...