Description of System

The models 1500, 1700 and 1800 fireplaces have been 

designed to accommodate the installation of an optional 

150CFM air circulation fan. The fan is designed to boost 

the natural convection through the heater; this may be 

a desirable feature dependent on the fireplace location 

and room layout.

It is preferable to install the circulating fan before 

completing the heater installation

 although it may 

also be retrofitted at a later date provided the power re-

ceptacle has been prewired within the fireplace casing. 

Retrofitting the fan after the fireplace installation is com-

pleted will require disconnecting the gas and removing 

the burner module and gas train from the fireplace.
The fan is designed for automatic operation to come ON 

and OFF when the burner comes ON and turns OFF. The 

fan speed can be controlled from the remote control 

handset. There are four speeds available.
The fan, if turned ON, will start approximately 4 minutes 

after lighting the appliance and will continue to run for 

approximately 10 minutes after the burner is shut off. 

The fan will operate at the speed last selected by the 

user.
Future servicing or replacement of the fan may be done 

through the window aperture of the fireplace without 

needing to remove the fireplace from the wall cavity.

4007879-01

© 2019, Miles Industries Ltd. All rights reserved.

Electrical Requirements

This optional fan kit connects to a control module (sold 

separately) to be mounted within the fireplace casing.  
The fan electrical requirements are 

120 Volts, 1 phase, 

60 Hz. Full load current of less than 1 amp

1595CFKV2 CIRCULATING FAN KIT

Use with Valor models 1500K, 1700K and 1800K Linear Fireplaces

INSTALLATION & OPERATING INSTRUCTIONS

Linear

WARNING

If these instructions are not followed 

exactly, a fire or explosion may result 

causing property damage, personal 

injury or loss of life.

NOTICE 

A control module GV60VM—V-Module kit 

(sold separately) is required to provide 

power and speed control to the fan. The 

V-Module plugs into a receptacle located 

within the fireplace. Ensure power is 

provided to the receptacle. See Electrical 

Wiring section in fireplace installation 

manual for details.

Please leave this manual with the homeowner.

Summary of Contents for 1595CFKV2

Page 1: ... OFF when the burner comes ON and turns OFF The fan speed can be controlled from the remote control handset There are four speeds available The fan if turned ON will start approximately 4 minutes after lighting the appliance and will continue to run for approximately 10 minutes after the burner is shut off The fan will operate at the speed last selected by the user Future servicing or replacement ...

Page 2: ...Thermal switch Power cable with Molex connector Wiring diagram label Sheet metal screws 2 GV60VM V Module Kit sold separately containing V Module relay box Receiver to relay cable Power cord assembly with plug BLOWER BLOWER JUNCTION BOX WITHIN FIREPLACE GND RECEIVER TO RELAY CABLE 4002531 SUPPLIED SEPARATELY WITH FAN CONTROL MODULE 3 PIN MOLEX POWER CORD 37 LONG 4007877 POWER CORD ASSEMBLY 4006350...

Page 3: ...hes on the display Press the and buttons to set the fan speed No bar showing means the fan is OFF Press the button to confirm the setting or wait The fan icon and number of bars will show when the remote is in other modes to confirm the fan status There may be a delay if the fireplace has just been turned on Note When the heater is operated at lower settings the fan may cycle off and on repeatedly...

Page 4: ...ble before tightening screws 3 The thermal switch bracket is fixed to the underside of the firebox floor from the top Slightly loosen the two screws holding it and slide the thermal switch in between the bracket and the underside of the firebox floor Tighten the two screws to secure the switch in position Slide thermal switch between bracket and underside of firebox floor Remove fan fixing access ...

Page 5: ...rs Blower 4000537 Fan Mounting Bracket 4003053 3 pin Molex Power cord 37 long 4007877 Thermal Switch 4003065 Cable Switch to Motor 10 4003067 Ground cable eyelet each end 4003068 Clamp Self Adhesive 4000536 Schematic label 1595CFKV2 4007878 6 Plug the fan power cord molex connector into the control module marked FAN 7 Plug the 3 prong power cord into receptacle at the right into the fireplace case...

Page 6: ...lied must install the model 1595CFKV2 Circulating Fan Kit The defective components should be returned at your expense to the dealer from where the product was purchased or authorized service agent The sales invoice evidencing proof of purchase and date of purchase must accompany any components returned for warranty repair replacement Miles Industries Ltd reserves the right to repair and return any...

Page 7: ...me ou s éteint La vitesse du ventilateur peut être contrôlée avec la ma nette de la télécommande du foyer Il y a quatre vitesses pour ce ventilateur Le ventilateur lorsqu allumé commencera à fonction ner après environ 4 minutes suivant l allumage du foyer et fonctionnera jusqu à approximativement 10 minutes après que le foyer soit éteint Le ventilateur fonction nera à la dernière vitesse sélection...

Page 8: ...que de montage Interrupteur thermique Cordon d alimentation à Molex Schéma des connexions Vis à métaux 2 Module de commande GV60VM contenant Boîtier relai de commande V Module Câble relai au récepteur Cordon d alimentation à fiche BLOWER BLOWER JUNCTION BOX WITHIN FIREPLACE GND RECEIVER TO RELAY CABLE 4002531 SUPPLIED SEPARATELY WITH FAN CONTROL MODULE 3 PIN MOLEX POWER CORD 37 LONG 4007877 POWER ...

Page 9: ...ou attendez qu il se règle L icône du ventilateur et le nombre de barres seront visibles à l écran confirmant le statut du ventilateur quand la télécommande sera en d autres modes Il peut y avoir un délai de fonction si le foyer vient juste d être allumé Note Lorsque le foyer fonctionne en bas régime il est possible que le ventilateur s allume et s éteigne de façon répétée parce qu il n est pas po...

Page 10: ...e sous la boîte de foyer Dévissez légèrement les deux vis retenant le support de l interrupteur thermique et insérez l interrupteur entre son support et le dessous de la boîte de foyer Resserrez les vis pour fixer l interrupteur Foyers 1700 1800 J ou K fixez le ventilateur par le trou d accès Bas du foyer transparent pour clarification 4 Branchez le module de commande dans le récepteur 5 Branchez ...

Page 11: ...NG TO STUD ON MOUNTING PLATE Fixez l étiquette devant le ventilateur Boîte de raccordement dans le foyer en bas à droite Description Pièces no Ventilateur 4000537 Plaque de montage 4003053 Cordon d alimentation à connecteur Molex 37 de long 4007877 Interrupteur thermique 4003065 Câble Interrupteur au moteur 10 4003067 Câble mise à la terre oeillet à chaque bout 4003068 Serre fil auto collant 40005...

Page 12: ...ournies avec le kit Toute pièce défectueuse couverte par cette garantie doit être retournée aux frais de l acheteur au détaillant ou marchand ayant vendu ce kit ou à un agent autorisé Toute pièce présentée en vertu de cette garantie pour réparation ou remplacement doit être accompagnée du reçu de caisse ou facture à titre de preuve d achat Miles Industries Ltd se réserve le droit de réparer ou ret...