background image

Trust Communicator ISDN 128
Internal

User's Manual

Version 1.0

Summary of Contents for ISDN 128

Page 1: ...Trust Communicator ISDN 128 Internal User s Manual Version 1 0 ...

Page 2: ...anties of merchantability and fitness for a particular purpose with respect to the software the product manual s and written materials and any other accompanying hardware The manufacturer reserves the right to revise or make improvements to its product at any time and without obligation to notify any person of such revisions or improvements In no event shall the manufacturer be liable for any cons...

Page 3: ...e To set up a remote network some knowledge about network operating systems is needed The following conventions are used in this manual for giving instructions Control Panel A special term from the software e g the Windows Control Panel Enter A key to be pressed e g the Enter key c setup A command to be entered through the keyboard Extra information for the user is given like this Note Do not form...

Page 4: ......

Page 5: ...ings 17 5 4 Trust ISDN WAN NDIS Miniport 18 5 4 1 Installing 18 5 4 2 Configuring Internet Access 20 5 4 3 Multi channel PPP set up 23 Chapter 6 Testing and troubleshooting 27 6 1 Testing the hardware 27 6 2 Testing the ISDN connection 28 6 3 Reconfiguring the Trust Communicator ISDN 128 Internal 29 6 3 1 Hardware settings 29 6 3 2 ISDN settings 30 6 4 Troubleshooting 31 Appendix A Technical Data ...

Page 6: ...2 ...

Page 7: ...ter Pentium processor 8 MB of RAM recommended 16 MB Windows 95 operating system A free 16 bit ISA slot 10 MB hard disk space Note The Trust Communicator ISDN 128 Internal has been designed for use with Windows 95 It does not work with Windows 3 11 DOS Windows NT and OS 2 The package contains programs for the various ISDN services There are 3 disks and 1 CD ROM included in the package They have the...

Page 8: ... the Internet Note If you use your ISDN adapter only to access the Internet and not for other ISDN services a faster installation is available by first installing the IAP chapter 5 4 1 part 1 2 and then following the instructions in chapter 3 and 4 ...

Page 9: ...for your Basic Rate Interface is determined by your local phone company When installing your software you will be requested to enter the type of D channel protocol your BRI is configured to The Trust Communicator ISDN 128 Internal supports the most common D channel protocols and ISDN switch types European protocols International protocols US ISDN switch types ETSI EURO ISDN INS64 Japan AT T Custom...

Page 10: ...6 ...

Page 11: ...plug in the wall outlet might damage the machine and expose you to dangerous voltages inside Especially ATX type computers might switch on by themselves when cards are added or removed if left powered on You may need a medium size Phillips screwdriver to open the case of your computer Follow these steps If your computer is already switched off proceed with step 3 1 Shut down your operating system ...

Page 12: ...e other end to the ISDN connector on the Trust Communicator ISDN 128 Internal See figure 1 9 Replace the cover of your PC and reconnect the mains plug The installation of the card is now completed There are no jumpers or switches to be set on the card All settings are performed through software ISDN Connector ISA slot Figure 1 The Trust Communicator ISDN 128 Internal adapter card ...

Page 13: ... be installed After this you can choose to run the card with the included application software or to install the Microsoft ISDN Accelerator Pack and the Miniport driver for Internet access at 64 or 128 kbps Follow these steps 1 Start up Windows 95 Windows 95 will display the New Hardware Found dialogue box This screen may look different in your Windows version Figure 2 The New Hardware Found scree...

Page 14: ...ult target directory C TRUST Figure 3 The ISDN parameters 9 Click on the Trust Communicator ISDN 128 Internal adapter Properties sheet to specify the D channel protocol See figure 3 10 From the list box select the D channel protocol your ISDN line is configured to For EURO ISDN choose DSS1 11 Fill in the tariff unit to be used for counting and indicating charges for each call you make If you don t...

Page 15: ...ccept Automatic by clicking Next The protocol you selected previously for the CAPI driver will be used 18 Now you can fill in the telephone numbers you have been assigned by the telephone company You can apply for more than one number for each line and assign different numbers to fax voice and data terminals This is only required if you will be using the Miniport drivers for incoming calls also 19...

Page 16: ...12 ...

Page 17: ...software This section describes the set up for other applications 5 1 The VCOM modem emulator Installed together with the CAPI driver the Trust VCOM driver automatically sets up a series of preconfigured modems To make sure just take a look at the modem list under Modems in the Control Panel You can use these modems as if they were conventional devices Modem type Configuration Trust Modem Standard...

Page 18: ...B 4 Packet size Window size from 128 to 16384 from 1 to 7 X 75 T 90 NL B 5 Packet size Window size from 128 to 16384 from 1 to 7 X 75 Btx B 6 Packet size Window size 128 7 HDLC B 1 Packet size Window size from 128 to 16384 from 1 to 7 V 110 B 3 Transmission rates Data bits Parity Stop bits from 1200 to 38400 bps from 4 to 8 None Even Odd Mark Space 1 1 5 and 2 V 120 B 8 Transmission rates Data bit...

Page 19: ...the Trust Communicator ISDN 128 Internal that has similar settings to the modem you wish to install 7 Click Next 8 Select the port you want to use with the modem either Trust VCOM modem COM3 or COM4 The COM port might be different depending on the configuration of your system 9 Click Next Trust VCOM will use the port you selected 10 Click Finish The list of preconfigured modems shows e g Trust Mod...

Page 20: ...e The installation of a new modem in Windows 95 may vary across different versions and languages of this operating system Read the manual of your Windows version if you encounter problems during installation ...

Page 21: ...ttings select Control Panel 2 Double click Modems 3 Click the modem you want to set up from the list 4 Click Properties The resulting screen looks like figure 4 Figure 4 The Properties panel for your Trust VCOM modem Note See the manual of your application or contact your provider to get the values to be entered here The selections have the following meaning Connected Port Select e g COM3 or COM4 ...

Page 22: ...unterpart s protocol Note Trust VCOM saves the most recent settings However these settings may sometimes be disabled when your COM port application automatically initialises on start up 5 4 Trust ISDN WAN NDIS Miniport Trust ISDN WAN NDIS Miniport is an interface that lets you use Windows 95 Dial Up Networking and Microsoft ISDN Accelerator Pack IAP You can use two B channels together to obtain a ...

Page 23: ...ersion from the Internet at the Microsoft home page 2 Check if your computer is set up to use Dial Up Networking Usually it is installed together with IAP If the Dial Up Networking icon is not in My Computer it is not installed To install Click Start point to Settings select Control Panel Double click Add Remove Programs The list of installed applications is displayed Click the Windows Setup tab t...

Page 24: ...er with the Miniport driver Other protocols need to be installed manually See the network part of the Windows 95 manual if you are not sure how to do this If you want to check protocol bindings click Start point to Control Panel double click Network Select TCP IP from the list of network components click Properties and click the Bindings tab 5 4 2 Configuring Internet Access With Trust ISDN WAN ND...

Page 25: ...tion A window similar to figure 5 will be displayed 4 Click Add to add a new connection 5 Type a name for the connection e g the name of the computer you are dialling 6 From the modems list select Trust Miniport 1B channel as the type of dial up adapter 7 Click Next A new dialogue box will appear 8 Enter the phone number you want to dial the area code and the country code ...

Page 26: ...e found in the Connection tab 11 Select the Server Types tab A window similar to that in figure 6 will be displayed Figure 6 The parameters for the network connection 12 Make sure the Type of Dial up Server is set to PPP and TCP IP is checked 13 Click TCP IP Settings A windows similar to figure 7 will be displayed 14 Enter your IP and DNS addresses into the resulting dialogue box This information ...

Page 27: ... IP networks at 128 kbps This set up uses two B channels of 64 kbps joined together This gives double speed but will also cost a double phone company fee This setting can only work if the Microsoft Internet Accelerator Pack is installed and if your provider supports dual channel access Complete the following steps to install 1 Click My Computer 2 Double click Dial Up Networking A list with all you...

Page 28: ...s correct 7 Click Settings 8 Click Use additional devices 9 Click Add to assign an extra line to the connection 10 Select Trust Miniport 2B channel from the list This will be your second line 11 Check the phone number and make sure it matches the one in step 6 The resulting window should look like Figure 9 12 Click the OK button to return to the connection settings 13 Click OK to finish 14 Close t...

Page 29: ...25 Figure 8 The connection properties window Figure 9 The extra channel assigned ...

Page 30: ...26 ...

Page 31: ...sts gives an error you will have to solve this first before a successful connection can be made 6 1 Testing the hardware This test is intended to check that your board s components are operational Test as follows 1 Point to the Trust ISDN Monitor icon on the Windows 95 task bar while clicking the right mouse button 2 Select Properties 3 Click Test Hardware A status window shows the condition of va...

Page 32: ...a test connection to your own ISDN line using the number you have entered into the Properties sheet 1 Point to the Trust ISDN Monitor icon on the Windows 95 task bar while clicking the right mouse button 2 Select Properties and click The Properties sheet will be displayed 3 Click Test ISDN Line The communication will take a few seconds 4 Watch the messages on the screen The Trust Communicator ISDN...

Page 33: ...e Trust Communicator ISDN 128 Internal In rare cases you may wish to manually reconfigure your Trust Communicator ISDN 128 Internal To do so use the Device Manager of Windows 95 6 3 1 Hardware settings Use the following steps to change the hardware settings 1 Select your board from the list of hardware components Open the Properties sheet and click the Resources tab A window looking like the one i...

Page 34: ...on You can modify these settings D channel protocol of your ISDN switch Connection charges if supported by provider Your own telephone number for the ISDN line test Make sure this is correct otherwise the ISDN test will fail Toggle the check box for showing the Trust ISDN Monitor on the Windows 95 task bar EAZ Mapping Complete this dialogue box only if you run ISDN applications on CAPI 1 1 and you...

Page 35: ...ation a Cause Drivers are missing or installed wrongly a Remedy Test the hardware with the ISDN monitor Remove all drivers for the Trust Communicator ISDN 128 Internal and restart the system Make sure to check remove any Trust Communicator ISDN 128 Internal drivers in the Unknown Device part of the Windows 95 list of devices b Cause Your computer has no PnP BIOS The drivers are not installed Windo...

Page 36: ... one is available d Remedy Remove some devices from your system 2 Symptom The card is tested OK with the hardware test but the modem application cannot find any modem a Cause The CAPI drivers are missing or damaged a Remedy Do the ISDN line test Remove all Trust Communicator ISDN 128 Internal drivers and reboot your system to re install b Cause No modem is defined or the parameters are wrong in th...

Page 37: ...does not support ISDN on the number you try to connect to Most providers have several numbers but do not provide ISDN support on all numbers c Remedy Contact the provider for the right number d Cause The password or the user name is incorrect Most providers host systems will disconnect immediately if the password is wrong d Remedy Contact the provider for the right information e Cause Wrong networ...

Page 38: ...l up networking properties to Add additional devices to this connection b Cause The Microsoft ISDN accelerator Pack has not been installed b Remedy Install from the disk included or download the latest version from the Microsoft Internet home page and install c Cause The provider does not allow multiple channel access c Remedy Select another provider ...

Page 39: ...inating the need for any DOS memory 64 kbps or 128 kbps transmission rate 16 bit ISA bus RJ45 ISDN connection Suitable for use in the USA and Europe Passive design Available interrupt lines 3 4 5 9 10 11 12 and 15 Power consumption less than 2 W Approved for ISDN connections in Europe Complies with CE regulations according to EN 80052 1 and EN 55022 class B ...

Page 40: ...36 ...

Page 41: ...ansmission without interruption Capable of detecting and correcting transmission errors Used for file transfer modem communications HDLC transparent High Level Data Link Control Protocol for point to point and multi point communications Uses frame check sequence and framing structure of HDLC Enables faster rates than X 75 H 221 ITU T framing recommendation which is part of the H 320 standard serie...

Page 42: ...38 ...

Page 43: ...ost recently typed command This is useful if a dialling attempt fails Note that the slash already causes the command to be executed Therefore you need not type the Carriage Enter character which might be mistaken as an instruction to break off dialling 2 Use three Escape characters e g to quit the on line mode Be sure to pause for one second before and after typing the Escape characters On the oth...

Page 44: ...ing V 110 type one of the following initialisation strings atb3s34 38400s35 8s36 10s37 0 Enter or atb3s34 38400s35 7s36 10s37 1 Enter Note To access CompuServe using V 120 type the following initialisation string atb8s34 64000 Enter ...

Page 45: ...ction Switches from command mode to on line mode ATO ATQ Quiet Display result messages ON 0 OFF 1 ATQ1 ATSn v Set Set register to desired mode also refer to Register Description ATS0 1 ATSn Show Display register contents ATS0 ATV Verbal Result code format Verbal 1 numeric 0 ATV0 ATX eXtension Disable messages ATX0 ATZ initialiZe Disconnect load profile 0 3 initialize ATZ AT C Cd control Control DC...

Page 46: ...tly be reported to be active AT R1 AT S DSR control Control DSR line DSR line is always active AT S0 DSR line is active only if connection is set up AT S1 AT V Verbalize Display profiles preconfigured phone numbers AT V AT W Write profile Save current profile 0 3 AT W1 AT Y Set initial profile for start up 0 3 AT Y1 AT Zn n Save phone number 0 3 AT Z2 019 10 AT G Automatic flow control between VCO...

Page 47: ...nection messages AT V0 AT A Additional info Handle additional V 110 info AT A3 AT N no fast connection Suppress high bit rates in CONNECT messages AT N1 AT P Phone number Set own phone number AT V Videotex Videotex settings AT V3 ...

Page 48: ...Command settings as bitmap AT E Q V 170 20 Command settings as bitmap AT B 002 21 Command settings as bitmap AT C D R S 048 22 Command settings as bitmap AT X 247 23 Command settings as bitmap AT G 000 24 Command settings as bitmap AT E I H V 000 25 Command settings as bitmap AT A G 010 29 User rate access to ITU V 110 000 30 Most recent error code reported by CAPI hexadecimal 0000 34 Transmission...

Page 49: ...46 Window size for X 75 T 70 NL 002 47 Packet size for X 75 T 70 NL 130 48 Window size for X 75 T 70 NL VTX 002 49 Packet size for X 75 T 70 NL VTX 130 54 Window size for V 120 007 55 Packet size for V 120 512 AT W command does not save marked registers ATS30 n cannot alter register 30 ...

Reviews: