background image

Zen 

Pro

minipool

Installation manual 

Summary of Contents for Zen Pro

Page 1: ...Zen Pro minipool Installation manual...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...______ 10 2 QUALIFICATIONS OF THE INSTALLER ________________________________________________ 10 3 CONNECTIONS REQUIRED__________________________________________________________ 11 4 PLUMBING CONNECTIO...

Page 4: ...modifications that do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not pl...

Page 5: ...in compliance with current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the minipool at the end...

Page 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precautions for those inv...

Page 7: ...nipool into the prepared space If it was not possible to provide a technical inspection port on all sides of the minipool a pneumatic lift is available OPTIONAL to be requested from the Manufacturer i...

Page 8: ...e If necessary contact the Manufacturer for more details When filling is complete reposition the filter in its compartment and check that the connections are correct and that there are no leaks LEGEND...

Page 9: ...clean and verify that the gaskets are still in place INTERIOR top view Caution Make sure that the six internal filters are correctly positioned and secured see figure C A 1 3mm 1 3mm 23 cm 7 cm 1 3B...

Page 10: ...THE INSTALLER Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer q...

Page 11: ...and plumbing connection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR MI...

Page 12: ...al connections Drain Loading supply Technical inspection port IN incoming hot domestic water OUT outgoing cold water 230V C S P in out PR TC EV BS P2 BL 1 BL2 HTR Cromo 230V EVc EVs EVclv 230V heater...

Page 13: ...Ideal values of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it poss...

Page 14: ...le hose provided If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the dra...

Page 15: ...east 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable m...

Page 16: ...and properly connected to the pipes The water connections have been made properly in accordance with local and national codes and that they can guarantee a perfect seal verification to be carried out...

Page 17: ...maximum sensor does not detect water SL2 0 activates automatic filling until conditions are restored and for a maximum of 60 minutes If the lack of water is considerable e g two or more people get ou...

Page 18: ...east 2 3 minutes to expel the air that may be present in the plumbing system 4 WATER TEMPERATURE ADJUSTMENT When one of the two keys or is pressed once the display shows the current setting default 35...

Page 19: ...ctivate it When the function is activated the display will show the word LOCK for six seconds and then return to showing the water temperature To disable the function press the OK key again for three...

Page 20: ...hen the SILENCE function starts the SILENCE function remains suspended and will become active 10 minutes after the user function has been switched off If a user function is activated by the user while...

Page 21: ...recirculation pump from running in the event of potential danger It is activated when the recirculation pump is running the flow switch does not detect flow for at least five seconds The display show...

Page 22: ...es are not dirty 2 Water supply with low pressure make sure that the minipool s supply pressure is between 1 5 and 3 bar 3 Leaks in the bathtub s pipes make sure that there are no leaks in the bathtub...

Page 23: ...After the first cleaning of the bottom the problem should no longer exist Cleaning the bottom with a minipool cleaner Make sure you have used sand with granularity from 0 5 to 1 mm suitable for this t...

Page 24: ...24 Zen Pro minipool EN Mount the wood or laminate resin panels as shown in the figures below Decorative panels 1 2 3 1 3 2...

Page 25: ...Under these conditions or when not used advise the owner to use a fixed or mobile cover to protect the minipool we recommend the optional Treesse covers In addition to preserving the surfaces the cov...

Page 26: ...Notes Notes...

Page 27: ...e small differences between this manual and the product you have received we apologise in advance for any inconvenience The total or partial reproduction of this manual without the Manufacturer s cons...

Page 28: ...Zen Pro installation Edition 03 2018 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it...

Reviews: