Connection and installation manual

ST 63 control unit  

for folding and swing gates

Safety Sensor

Summary of Contents for ST 63

Page 1: ...Connection and installation manual ST 63 control unit for folding and swing gates Safety Sensor...

Page 2: ...Photocells 17 Safety edges 20 Left leaf 21 Right leaf 21 Operating mode 22 Light lamps 23 Peripherals 24 Diagnosis 28 3 Connecting the receiver 29 4 Putting into operation 30 5 Optional Traffic light...

Page 3: ...purpose for which it has been exclusively designed and which is described in these installation and operating instructions The TOUSEK Ges m b H rejects any liability if the product is used in any way...

Page 4: ...on is pressed hold Emergency mode deadman mode without safety devices in case of malfunction 1K ST63 for 1 leaf in plastic housing 295 x 340 x 130mm 1 2 ST63 for 1 or 2 leaves in steel housing 600 x 3...

Page 5: ...USE OF DEVICE Read this manual carefully before installing and using the converter Adjustment of parameter settings have to be done by trained professionals DANGER OF ELECTRIC SHOCK OR ELECTRIC ARC A...

Page 6: ...rminal block for 230Va c power supply speed sensor and grounding connection In the steel housing version the supply voltage is connected to the main switch HS Expandability with the optional component...

Page 7: ...quency converter main switch and the connection to the terminals KL2 on the DIN rail are carried out at the factory The connection works of the operator must be carried out according to the installati...

Page 8: ...on optional D Display connection or TC TSI connection optional tousek connect tousek service interface TA additional pulse button corresponding to term 30 32 FU L MODBUS FU connection for LEFT leaf FU...

Page 9: ...sensor Drehzalsensor Sensorsignal 2 rechts Drehzahlsensor 1 2 3 1 2 3 power supply PHC transmitter power supply PHC receiver or accessories max 0 3A common PHC PHC contact inside PHC contact outside P...

Page 10: ...or wires must be connected for the left operator according to the chart below sensor wires connection to the terminal block KL2 The sensor wire must not exceed the max length of 50m For lengths of mor...

Page 11: ...nts Take care of the right connection between the metal tongues in the holes and the shield of the motor wire M cable bolting M16 1 2 3 1 2 3 S M S M shield shield shield M S M S shield Article no mot...

Page 12: ...nd the display Before starting the programming please choose the language Use the buttons or to choose menu langua ge and confirm with ENTER Note Language selection can also be chosen by pressing the...

Page 13: ...ctive closing active opening closing SE status display Display status safety edges SE left leaf page 21 delay left leaf opening delay closing delay delay time left leaf OFF 1 25s 2s force 60 100 70 sp...

Page 14: ...lamp OFF 0 1 1s electric lock not active 1 10s drop bolt OPEN and CLOSE OPEN only CLOSE only additional module gate status display 1 gate status display 2 diagnosis page 28 status display state displa...

Page 15: ...it is closed IMPORTANT Do not put into operation in dead man mode Select only after putting into operation page 30 if desired buttons switches Anschl sse und Einstellungen A general status display of...

Page 16: ...s switch is released the gate movement stops STOPP switch N C contact terminals KL1 30 31 Buttons switches when pressing the stop switch the gate stops in any desired position As stop switch a break c...

Page 17: ...over If impluse mode is selected a new CLOSE impulse must be given Important Photocells notes Photocell connection the control unit has a power supply connection for a 24V a c photocell PHC power sup...

Page 18: ...open position has been reached and the safety device has been released In traffic light mode only the adjustments no inluence and immediate closing after opening are available PHC self test Photocell...

Page 19: ...safety device 24Va c 12 240V a c d c NO NC COM COM 49 48 46 45 44 43 42 41 KL1 Important Jumper J of transmitter and receiver has to be adjusted in the same way Outer photocell Tousek LS 26 as safety...

Page 20: ...t triggered status triggered status contact strip not connected or defect status contact strip deactivated in menu o x e g LL1 LL2 RL1 RL2 SE status display Safety edges Status dsplay of safety sensin...

Page 21: ...ng direction Left leaf Connections and adjustments delay right leaf Right leaf opening delay the left leaf opens after the adjusted delay time closing delay the left leaf closes after the adjusted del...

Page 22: ...e opening the gate closes automatically after the adjusted pause time In traffic light mode automatically only complete opening is active only pedestrian opening only after partial opening the gate cl...

Page 23: ...each closing movement the signal lamp flashing light is activated for the adjusted time Light lamps Connections and adjustments green phase 20s factory setting Light lamps 5 120s adjustable increment...

Page 24: ...ock to not active afterwards locking Peripherals Electric lock magnetic clamp locking with optional Electric lock magnetic clamp module Electric drop locking with additional electric drop module rever...

Page 25: ...he module evaluation of gate status has to be plugged to the according slot plug ZM of control board Additionally the corresponding value has to be selected in menu point Additional module Additional...

Page 26: ...rals locking and peripherals electric lock Magnets are driven into the open and closed position of the gate the electric lock only in closed position The series resistor R is for tousek magnets GD 50...

Page 27: ...ed to the ST 63 or one dropbolt only terminal block X for two dropbolts terminal blocks X Y 230Va c a c power supply and grounding V of the dropbolt control unit Connection of dropbolt SAFELOCK option...

Page 28: ...s shows the software version on display gate type S swing gate F folding gate operator type X3TP X4TP serial number Diagnosis shows the serial number on display protocol Diagnosis shows the protocol l...

Page 29: ...ming of receiver please see manual for radio receiver Disconnect the power supply Plug in the receiver printed circuit board E RS433 868 STN1 1 channel or RS433 868 STN2 2 channels into the correspond...

Page 30: ...lected during initial operation hence after reset to factory settings Language selection can be also chosen by pressing the ESC button for 5s from any position in menu BASIC SETTINGS For setting the m...

Page 31: ...de not active change YES confirm 4 outer photocell REVERSING 4 PHC photocell PHC photocell LL left leaf RL right leaf LL1 LL2 RL1 9 safety edge RL2 safety edge RL2 open close safety edge RL2 not activ...

Page 32: ...ition being detected close position being detected ready automatic positioning START OPEN automatic automatic CLOSE system check PHC inside system check PHC outside system check safety edge LL1 system...

Page 33: ...impulse emission is only possible via traffic light board page 35 37 I loops pulse buttons radio When using a radio receiver in traffic light mode the receiver is not to plugged into the slot of the...

Page 34: ...ng started red traffic light warning and possibly signal light warning before opening the door duration adjustable via gate auto mation control board Gate opens after the prewarning time 3 Gate open l...

Page 35: ...g the control housing please switch off necessarily the main switch In supplied control inside the unit is powered the safety regulations to prevent electrical shock have to be respected The unit is d...

Page 36: ...utside to give an impulse for the green request The impulse is also possible via an optional plug in radio receiver The green switching for one or both sides is dependent on the adjustment of the traf...

Page 37: ...ceiver optional Traffic light control unit STA 11 Important When using a radio receiver in traffic light mode the receiver is not to plugged into the slot of the ST 63 but into the slot of the traffic...

Page 38: ...of all channels ISD STA 11 Insert the board of the induction loop detector on the slot ISD of the traffic light control unit STA 11 ISD 5 5 2 channel induction loop detector ISD 6 optional Traffic li...

Page 39: ...check correct connection display sensor right triggered display FC error left no connection between ST 63 and frequency converter check correct connection of the FC display FC error right display sea...