background image

Form No. 3405-472 Rev A

ExcelaRate Upgrade Kit

Multi Pro

®

5800 Turf Sprayer

Model No. 41642

Installation Instructions

WARNING

CALIFORNIA

Proposition 65 Warning

This product contains a chemical or chemicals known to the State of California to

cause cancer, birth defects, or reproductive harm.

Safety

WARNING

Chemical substances used in the spray system may be hazardous and toxic to you, bystanders, animals,
plants, soils, or other property.

Carefully read and follow the chemical warning labels and material safety data sheets (MSDS) for all
chemicals used and protect yourself according to the chemical manufacturer's recommendations. For
example, use appropriate personal protective equipment (PPE), including face and eye protection,
gloves, or other equipment to guard against personal contact with a chemical.

There may be more than 1 chemical used and information on each chemical should be assessed.

Refuse to operate or work on the sprayer if this information is not available.

Before working on a spray system, ensure that the system has been triple rinsed and neutralized
according to the recommendations of the chemical manufacturer(s) and that all the valves have been
cycled 3 times.

Verify that there is an adequate supply of clean water and soap nearby, and immediately wash off any
chemicals that contact you.

Installation

Loose Parts

Use the chart below to verify that all parts have been shipped.

Description

Qty.

Use

Pressure transducer

1

Cap fitting

1

Flange gasket

1

Flow meter

1

Flow meter gasket

2

Switch

1

Wire harness

1

Install the kit.

© 2016—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420

Register at www.Toro.com.

Original Instructions (EN)

Printed in the USA

All Rights Reserved

*3405-472* A

 

Summary of Contents for 41642

Page 1: ...ard against personal contact with a chemical There may be more than 1 chemical used and information on each chemical should be assessed Refuse to operate or work on the sprayer if this information is...

Page 2: ...er 4 Remove the clamps gaskets and manifold coupler Figure 1 Note Retain the clamps 5 Install the flow meter and 2 flow meter gaskets using the clamps that you just removed Figure 1 6 Remove the trans...

Page 3: ...Switch 2 Plug 10 Install the switch into the hole Figure 4 11 Beneath the dashboard connect the wire harness to the switch then connect it to the machine wire harness Note The connector on the machine...

Page 4: ...2 13 14 15 G035692 Figure 5 1 Master boom switch indicator on 5 Tank volume indicator US gallons 9 Selected application rate boost rate indicator on 13 Active application rate gpa 2 Right boom section...

Page 5: ...at Figure 5 Selected Application Rate Boost Rate Indicator The selected application rate boost rate indicator displays when either the selected application rate and or the boost rate are active Figure...

Page 6: ...usly to select Rate 1 or press and hold buttons 4 and 5 simultaneously to select Rate 2 Note From the Home screen press and hold buttons 1 and 5 simultaneously to apply boost rate Boost is active only...

Page 7: ...3 Press button 1 or 2 until you reach the desired unit and then press button 4 to select this unit English mph gallons acre Turf mph gallons 100 ft SI metric kph liter hectare Change the InfoCenter d...

Page 8: ...5 Enter PIN 3 Digit 3 3 From the PIN Settings screen press button 4 to select PIN Entry and to turn the PIN on or off Figure 16 Figure 16 Change the InfoCenter PIN as follows 1 Press button 2 on the...

Page 9: ...Enter your new PIN using buttons 1 to 4 and press button 5 when you complete your new PIN Figure 19 Figure 19 1 Digit 1 4 Digit 4 2 Digit 2 5 Enter PIN 3 Digit 3 6 Confirm your new PIN using buttons 1...

Page 10: ...ctions must be on when performing the catch test 8 Start at 2 75 bar 40 psi and use the application rate switch to adjust the spray pressure so a catch test yields the volume displayed for the selecte...

Page 11: ...a Calibration Successful screen appears press button 5 to exit 12 If the calibration is not successful a Calibration Failed screen appears with the reasoning behind why the calibration failed press b...

Page 12: ...ect About Figure 26 This screen displays the model number and serial number of your machine G034285 Figure 26 InfoCenter Spray Area Screens From the Home screen press and hold button 5 to open the men...

Page 13: ...ub area 4 Volume sprayed in the active sub area US gallons 2 Area sprayed in the active sub area acres 5 Select the previous sub area hold the button to reset area and volume sprayed for the active su...

Page 14: ...isories Condition Code Qualifier Display Text Start Prevented 2 Pump switch active To start turn pump off Start Prevented 3 Not in NEUTRAL To start return traction pedal to neutral Start Prevented 4 O...

Page 15: ...Parameter Status 503 A value is outside the range of accepted values Parameter status invalid data defaults used Booms Turned Off 802 Speed dropped Booms turned off stopped or moving too slowly 15...

Page 16: ......

Reviews: