background image

1

www.UsePhoenix.com  •  [email protected]

Toll-Free 1-800-533-7533

Owner’s Manual   —   Phoenix 270HTx

Installation, Operation & Service Instructions

Read and Save These Instructions

 The Phoenix 270HTx LGR,  

High Capacity Dehumidifier 

 

 

Phoenix 270HTx
4028600

Specifications subject to change without notice.

TS-584b

12/09

4201 Lien Rd.• Madison, WI 53704

• 

Automatic Bypass Technology – 

Patented 

technology automatically adjusts for 
temperature variation, increasing performance 
over a wider operating range.

• 

High Capacity - 

Removes 161 pints per day at 

AHAM

• 

8.9 amps - 

Removes over 6.5 pints/kWh.

• 

R-410A Refrigerant

• 

More Grain Depression - 

Drier air from an LGR 

finishes jobs quicker versus a conventional 
refrigerant dehumidifier.

• 

Focused Airflow - 

Patented focused outlet 

directs air downward across the wet surface.

• 

Motorized Impeller - 

380 CFM; Faster drying 

and superior static pressure for ducting.

• 

Multiple Ducting Options - 

12” intake, 10” 

exhaust.

• 

Solid State Controls - 

Easy to read and operate.

• 

Recessed 12” Wheels - 

Allows greater 

maneuverability on the job site and efficient 
storage. Rolls over obstacles with ease.

• 

MERV-11 Pleated Media Air Filter 

The Phoenix 270HTx is one of the most effective and versatile drying devices available. The Phoenix 270HTx features more 
water removal (161 pints per day@AHAM) and higher grain depression than other refrigerant dehumidifiers, while drawing 
only 8.9 amps of electricity.
The 270HTx features Phoenix’s patented bypass design, which is now enhanced to compensate for temperature 
automatically.  By sensing and adjusting to temperature changes in the drying chamber, the 270HTx maximizes water 
removal over an extended operating range without the need for manual adjustments.  
At higher temperatures, where typical LGRs lose effectiveness, the Phoenix 270HTx automatically adjusts to continue 
removing moisture. This offers several advantages to the restorer, including faster evaporation rates, quicker drying, and 
elimination of the need to remove or modify equipment for temperature control. 

Summary of Contents for Phoenix 270HTx

Page 1: ...12 intake 10 exhaust Solid State Controls Easy to read and operate Recessed 12 Wheels Allows greater maneuverability on the job site and efficient storage Rolls over obstacles with ease MERV 11 Pleat...

Page 2: ...walls and other obstructions to air flow Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 270HTx 2 2 2 Location 2 2 3 Electrical Requirements 3 2 4 Conden...

Page 3: ...oir before transport or storage Turn off the power and allow the plugged in dehumidifier to rest 15 minutes before the final purge 2 8 Hour Meter The digital hour meter displays the cumulative and job...

Page 4: ...d If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polyet...

Page 5: ...cuit 2 Obstruction prevents impeller rotation 3 Defective air mover 4 Defective control board Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humid...

Page 6: ...ng the pump bracket to the base 5 Replace the pump hose wiring bolts and cover in the reverse order 4 6 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge mus...

Page 7: ...7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram 4028595...

Page 8: ...peller 15mfd 371V 1 4025224 14 Thermistor Coil 1 4027278 15 Thermistor Bulkhead 1 4028581 16 Battery AA 4 8523901 17 Cord 115V 25 1 4025078 18 Compressor 10 2KBTU R410a 1 4029176 19 Overload Compresso...

Page 9: ...9 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Page 10: ...anty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Reviews: