background image

GB

Installation and  
operating instructions 

Digital time switch 

TR 

TR 608 top2 S 

6080101

TR 609 top2 S S 

6090101

D

GB

F

I

E NL

309364

MENU OK

230-240V~

50-60Hz

R10a  -25T

16(4)A  250V~

1

2

TR 609 top2 S

µ

L

N

2

1

N
L
L

max.

 100 m

Ext1

MENU OK

230-240V~

50-60Hz

R10a  -25T

16(4)A  250V~

1

2

3

µ

L

N

3

2

1

N
L
L

TR 608 top2 S

TR 609 top2 S

TR 608 top2 S

Connection of 
different external 
wires is permitted

Summary of Contents for TR 608 top2 S

Page 1: ...top2 S S 6090101 D GB F I E NL 309364 MENU OK 230 240V 50 60Hz R10a 25T 16 4 A 250V 1 2 TR 609 top2 S L N 2 1 N L L max 100 m Ext1 MENU OK 230 240V 50 60Hz R10a 25T 16 4 A 250V 1 2 3 L N 3 2 1 N L L...

Page 2: ...nu item PROGRAMM Program switching time 8 Check modify switching time 10 Delete switching time 11 Pulse time programming 12 Cycle time programming 14 Menu item TIME DATE 15 Menu item MANUAL 16 Overrid...

Page 3: ...is inserted in battery operation Designated use The time switch can be used for lighting bell systems ventilation etc Only use in enclosed dry spaces Do not use on safety devices e g escape route door...

Page 4: ...sents query bbbb 2 Make a decision MENU Activate screen Open menu Cancel menu ESC 1 step back OK Store selection Confirm selection Options are displayed MENU OK 230 240V 50 60Hz R10a 25T 16 4 A 250VAC...

Page 5: ...ug in screwless terminal press screwdriver downwards Warning danger of death through electric shock Must be installed by qualified electrician Disconnect power source Cover or shield any adjacent live...

Page 6: ...END 19 05 11 ON 35 9 40 1 NEW CHECK MODIFY DELETE END MENU TIME DATE TIME DATE SU WI WEEK DAY FORME DATE FORME TIME END MANUAL PERM ON PERM OFF OVERRIDE ON TIMER HOLIDAY RANDOM END OPTIONS OPERATING...

Page 7: ...l start up Set date time and summer winter time rule Press required key and display follows on screen see figure or ok ENGLISH RETAIN PROGRAM DELETE PROGRAM FORME DATE 31 05 11 7 RESET Press the 4 but...

Page 8: ...by pressing OK The display shows HOUR Use the or keys to enter hour minute 07 30 and confirm by pressing OK MONDAY is displayed Confirm by pressing OK COPY is displayed Confirm by pressing OK ADD TUE...

Page 9: ...MENU ON 7 30 9 GB PROGRAM NEW SWITCH ON PULSE TUESDAY WEDNESDAY CYCLE END HOUR MINUTE MONDAY COPY ADD TUESDAY SAVE SAVE 84 memory locations are available TR 609 top2 S...

Page 10: ...OK NEXT is displayed Change individual switching times Press to select MODIFY Confirm by pressing OK The display shows SWITCH Confirm by pressing OK The display shows the first time switch MONDAY Con...

Page 11: ...by pressing OK The display shows SWITCH Confirm by pressing OK MONDAY is displayed Confirm by pressing OK The display shows DELETE BLOCK Confirm by pressing OK The display shows DELETED With CLEAR MON...

Page 12: ...d Select PULSE by pressing u Confirm by pressing OK ON is displayed Confirm by pressing OK The display shows HOUR Use the or keys to enter hour minute second 8 05 and confirm by pressing OK PULSE LENG...

Page 13: ...MENU GB ON 8 05 PROGRAM NEW SWITCH PULSE CYCLE END ON HOUR MINUTE SECOND PULSELENGTH IN MINUTES PULSELENGTH IN SECONDS MONDAY TUESDAY WEDNESDAY SAVE COPY ADD TUESDAY SAVE 13 Length 5 sec...

Page 14: ...le times refers to cyclically repetitive time functions such as fan controls urinal rinses etc Example Switch on water rinsing Monday from 8 00 to 20 30 hrs every 15 min for 20 sec 8 0000 8 0020 On 8...

Page 15: ...nged in the submenus Press MENU using u select DATE TIME and follow the indications on the display MENU TIME DATE TIME HOUR MINUTE 20 10 15 SET DATE SU WI WEEKDAY FORM DATE FORME TIME END YEAR 31 12 1...

Page 16: ...an be activated programmed Press MENU using u select MANUAL and follow the indications on the display 16 only with TR 609 top2 S MENU MANUAL PERM ON PERM On 20 15 30 PERM OFF OVERRIDE ON TIMER HOLIDAY...

Page 17: ...figures Override Reversing the channel status to the next automatic or programmed switching Permanent switching As long as a permanent switching on or off is activated the programmed switching times...

Page 18: ...ing u select OPTIONS and follow the indications on the display 18 MENU OPTIONS OPERATING HOUR SHOW HOUR DELETE SERVICE END EXT INPUT LANGUAGE PIN FACTORY SETTINGS INFO END NOT ACTIVE LOAD FACTORY SETT...

Page 19: ...OPERATING HOUR EXT INPUT LANGUAGE PIN FACTORY SETTINGS INFO END WITH PIN NO PIN CURRENT PIN NEW PIN Enter PIN code The PIN Code is set in OPTIONS via the menu If you have forgotten your PIN call the...

Page 20: ...the indications on the display 3 submenus can be selected Inactive push button function switch function INACTIVE The external input has no function PUSH BUTTON Override manual switching timer Countdow...

Page 21: ...21 Use push button without glow lamp GB MENU OPTIONS OPERATING HOUR EXT INPUT INACTIVE BUTTON SWITCH OVERRIDE PERM ON PERM OFF TIMER TIMER ON HOUR MINUTE SECOND...

Page 22: ...ng with other storage transport methods Copy OBELISK Time switch This copies the switching program all stan dard and special programs and optionally all time switch e g Position offset external input...

Page 23: ...1000 W TR 609 top2 S 2000 W Fluorescent lamp load uncorrected series corrected 1000 W TR 609 top2 S 2000 W parallel correction 80 W 14 F TR 609 top2 S 1300 W 140 F Compact fluorescent lamps 30 W TR 60...

Page 24: ...RMANY Telephone 49 7474 692 0 Fax 49 7474 692 150 Hotline Telephone 49 7474 692 369 Fax 49 7474 692 207 hotline theben de Addresses telephone numbers etc www theben de The current OBELISK top2 PC soft...

Reviews: