background image

 

( 1 / 16) 

 

 

 

 

 

 

 

 

 

 

 

Instruction Manual 

 

 

Models: 

 

 

version 02.01 since 1 June 2017

 

 

 

 

ATTENTION! 

 

This instruction manual contains important information about the installation and the use of 

the equipment. Please read and follow these instructions carefully. 

 

Always ensure that the power to the equipment is disconnected before opening the 

equipment or commencing any maintenance work. 

 

RMCXX_en_manual_M175 

 
 

 

Rack Hoist Controller

 

RMC12, RMC8 

 

Summary of Contents for RMC12, RMC8

Page 1: ...s important information about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work RMCXX_en_manual_M175 Rack Hoist Controller RMC12 RMC8 ...

Page 2: ...ndards of design manufacture and the intended use of this equipment Do not operate in an explosive atmosphere Do not operate this equipment in the presence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard Water moisture heat and humidity Do not operate this equipment near water or in areas with wet floors or in high humi...

Page 3: ...ries controller Select type of operation LOCAL REMOTE using the KEY switch Check if the emergency STOP button is not engaged Engage the gear lever corresponding to each motor to the required position o UP Lever in upper position o STAY Lever in middle position o DOWN Lever in lower position Pushing the GO button will activate the motors that will move simultaneously Releasing the GO button will si...

Page 4: ...panel RMCseries rear panel E stop connector NC4FDL Remote A Remote B link connectors are 3 pin NC3MDL NC3FDL or NC3MAH and NC3FAH When controllers are linked via LINK the STOP and GO signals of all controllers in LOCAL mode work simultaneously ...

Page 5: ...nce the STOP button has been pressed it is locked into the off position and must be rotated clockwise to be released GO This pushbutton switch turns the selected channels of Hoist Control system on when they are active Once the GO button has been pressed the energizing of the hoists is on DIRECTION SWITCHES They allow changing the direction of movement for each motor hoist separately ...

Page 6: ...e system needs to be reset Red E STOP is active somewhere in the system RED blinking E STOP button is pressed on the device CMC DIGITAL Remote connector Neutrik NC5 FDL Pin Function note 1 Data CMN Data Common 2 Data Data Minus 3 Data Data Plus 4 DC1 Power supply for CMC DC12 36V 5 DC2 Power supply for CMC DC12 36V Housing Dimensions 2 0mm 3 0mm lightweight aluminum box CMC 12D 107 x 330 x 105 mm ...

Page 7: ...p 29 AC2 24V r r 30 GROUND s s E stop connector Unit is equipped with certified SIL3 E STOP safety relay For additional safety up to two sources of E STOP can be connected Usually one of them is the RMC unit and the other one should be the load cell unit According to the requirement both lines are normally closed NC Because of this it is necessary to fit the safety breach MXX connector with a shor...

Page 8: ...on link Neutrik NC3FXX MXX Pin 1 Data common Pin 2 Data minus Pin 3 Data plus CMC DIGITAL connection CMC remote connectors are used for linking of RMC with the CMC xx DIGITAL remote for remote operation with option to change directions Each RMC needs to be connected with CMC xx DIGITAL via 5pole digital cables STOP and GO signal is sent only to controller not to other linked units RS485 is used as...

Page 9: ...ts can be linked together for a group operation of GO buttons For linking of RMC base use a 3 pin XLR cable connected as 1 1 between pins 1 3 Data are transferred thru the RS485 line All connected devices will have GO E STOP button linked in the LOCAL mode ...

Page 10: ...ections and Safety Dry contacts all outputs are galvanic isolated Double Recessed Emergency stop SIL3 safety module Double encoded data communication Load cell E STOP External E STOP option Software update via USB Dimensions W x D x H RMC12 483 x 365 x 132 mm RMC8 483 x 365 x 132 mm ...

Page 11: ...heir correct functioning Warranty voids if any part or replacement components are installed or modified without authorization from the manufacturer and or the internal circuit is tampered or modified and or the controller is operated outside normal use conditions electrical power supply is not conform or there is connection error or mechanical damage of controller including overload improper use T...

Page 12: ...srs group com 421244681417 Declares that the product Name of product RMCseries hoist controller RMC8 RMC12 and variants Types RMC 8 Rack controller 8 channels RMC 12 Rack controller 12 channels Corresponds with following harmonized standards Safety EN60065 resp EN 60950 EMC EN55103 1 resp EN55103 2 And Is in compliance with the following requirements Machinery directive 2006 42 EC Low Voltage dire...

Page 13: ... 13 16 ...

Page 14: ... 14 16 ...

Page 15: ... 15 16 ...

Page 16: ...ions subject to change without notice Document RMCXX_en_manual_M175 Version 02 01 Actual as of 1 June 2017 SRS Group s r o Rybnicna 36 D 831 07 Bratislava Slovakia Phone 421 2 44 681 417 Fax 421 2 4468 1419 Email sales srs group com www srs group com ...

Reviews: