background image

Model

Panel Size(mm)

CN8-RC60W

48H×48W

48H×48W

72H×72W

72H×72W

48H×96W

48H×96W

2

2

2

2

2

2

1 Relay

1 Relay

1 Relay

1 Relay

Alarm output

Batch

CN7-RC60W

CN7-RC68W

CN4-RC60W

CN4-RC68W

 No

 No

Communication

No

RS485

No

RS485

No

RS485

CN 7 F R C 6 0

Alarm outputs

Control output

Power supply

48H×48W×97.5L

4

72H×72W×97.5L

7

AC/DC 100

240V 50/60Hz

Blank

AC/DC 24V

F

CN

48H×96W×97.5L

8

CN Series multi-function batch counter

W

Version

Version Code

W

1. Model Illustration

2. Model List

Dual line 6 digits LED display

2 Alarms

RS485 Communication Port

8

6

C

Relay

R

Blank

0

CN8-RC68W

CN W Series Multi-function Counter User Manual

2

1

Communication

Display digits

Dimension

Series

Safety Caution

To use this product safely and correctly and to prevent serious accidents, 

please company with the following points.

Warning   Failure to follow this point can result in serious injury or injury.

Caution    Failure to follow this point can result in injury or product 

damage.

The instruction of the symbol in the manual is as below.
Indicates that accidents or dangers may occur under special 

circumstances.

Safety Caution can be divided into two parts: "Warning" and "Caution", 

which means the following:

Warning

Caution

4.Communication parameters

Communication Protocol

Communcation type

Applicable specifications

Maximum connection quantity

Connection methord

Communication synchronization

Communication 

effective distance

Communication speed

Start bit

Data bit

Parity check

Stop bit

Modbus RTU ( 16bit CRC )

RS485
EIA RS485 Standard

31pcs ( communication add setting : 1~247)

Two-wire half-duplex

Asynchronous
800m Max
2,400 / 4,800 / 9,600 / 19,200bps

(Factory settings: 9,600bps)

1 bit ( fixed )

8 bit ( fixed )

None, Even, Odd ( Factory settings: None)

2bit

Features: 

Counting speed up to 20KCPS

Free setting ratio 0.00001

999999

Universal input.  Choose “NPN” or “PNP” input through software.

Batch or total accumulation function (except CI4W), optional 1 RS485 

communication interface.

Widely used in light industry, packaging, printing, textile, food and other 

industries for quantity and length counting.

1. Dual safety protection devices must be installed when used in 

machines that have a medium impact  on people and property, such 

as: nuclear power control, medical equipment, vehicles, railways, 

aviation,  combustion equipment, entertainment equipment, etc. Failure 

to do so may result in fire, death or property damage.

2. Be sure to install the panel when using it, otherwise there is danger of 

electric shock.

3. Do not perform maintenance work while the power is on, otherwise 

there is danger of electric shock.

4. Do not modify this product without authorization, otherwise it may 

cause electric shock or fire.

1. Do not use the product outdoors. Failure to do so may shorten the life 

of the product or cause an electric shock.

2. When wiring the power input terminal and relay output terminal, please 

use the AWG NO.20 (0.50mm2) cable  The torque of the screw is kept 

at 0.7N.m~0.9N.m. If the contact is poor, it may cause a fire.

3. Please use the product within the rated specifications. Otherwise, the 

life of the product will be shortened and there is a fire hazard. 

4.  Please ensure the loading less than the allowable capacity of the relay 

contacts. Failure to do so may result in poor insulation, contact 

melting, poor contact, relay damage, fire, etc.

5.  Do not use water or organic solvents when cleaning. Wipe with a dry 

towel.  Failure to do so may cause electric shock or fire.

6.  Avoid using this product in places that are flammable and explosive, 

humid, direct sunlight, heat radiation, vibration, etc.  Failure to do so 

may cause a fire or explosion.

7.  Do not allow dust or cable residue to enter the inside of the product.  

Failure to do so may cause fire or damage to the product.

CI4W

Series

CI7W

CI8W

6

6

6

3. Technical Specifications

Display digits

Text height  Measured value

Setting value

High voltage type

Low Voltage type

High voltage type
Low Voltage type

INA/INB max counting speed

Minimum signal pulse width

Input type

Control

output

Contact capacity

SSR capacity

Time output delay

Vibration resistant

Malfunction & 

impact resistance

External power supply

Power failure memory

Insulation resistance

Withstand voltage

Relay life

Environment

Anti-interference

AC power)

Vibration

shock

Malfunction

Mechanical

Electric

IP Grade

Certificate

Weight

Allowable voltage

variation range

Power 

Supply

Power

 Consumption

10mm

13mm

13mm

7mm

9mm

6mm

AC / DC 100-240V 50/60Hz

AC / DC 20-28V 50/60Hz

90%~110% of the power supply voltage
Below 12VA

Below 10VA

1Hz

30Hz

1KHz

5KHz

10KHz

20KHz optional

INHIBIT, BATCH, RESET signal for option

1ms, 20ms

0.01~499.99s

250VAC 3A Resistive load

below 30VDC , below 100mA

24VDC±10%, below 100mA

≥10 years

100MΩ

60 seconds below 2000VAC 50/60Hz

100m/s2(10G)X, Y, Z, 3 times in each 

direction

above 10 million times

above 100,000 times

Ambient 

temperature

Ambient 

Humidity

-10~55 ,  Storage: -25~65
35~85%RH,   Storage: 35~85%RH
CE

The surrounding environment must be in line with no ice, * no 

condensation. The weight here is the product net  weight without packing.

about 159g

about 169g

about 253g

IP65 for panel

10~55Hz (1 minute period) amplitude 

0.75mm X, Y, Z 1 hour in each direction
10~55Hz (1 minute period) amplitude 

0.5mm X, Y, Z 10 minutes in all directions 

300m/s2(30G)X, Y, Z, 3 times in each 

direction

Select voltage input mode or no voltage 

input mode

- Voltage input mode: Input impedance: 

5.4KΩ, "H" level voltage: 5-30VDC, "L" 

level voltage: 0-2VDC

- No voltage input mode: input impedance: 

1KΩ or less, short circuit residual voltage: 

2VDC or less

±4KV interference square wave (amplitude 

1us) generated by the analog jammer is 

applied between the power input terminals

KKCNW-A01E/A0/20221031

Reviews: