Summary of Contents for elicent REC-Duo 100

Page 1: ...recovery unit Instruction Manual ENGLISH v1 4 WARNING The equipment must only be installed by a specialised technician Read and apply the manual before carrying out the installation Keep this manual i...

Page 2: ...ogy and respects the standards in force regarding electrical equipment It conforms with the EMC European Directive in force regarding radio interference suppression and electro magnetic compatibility...

Page 3: ...es precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances Toavoid the risk of fire do not using the product in the presence...

Page 4: ...y The remote control does not work only in the Plus RC version Check the status of the battery DISMANTLING AND RECYCLING If a crossed out wheeled bin is illustrated on a product this means that the pr...

Page 5: ...Page 5 17 OPERATING PRINCIPLE Extraction Cycle Push Intake Cycle Pull 60 seconds 60 seconds DIMENSIONS Main Unit REC Duo 100 EXTERNAL VENT EXTERNAL COWLING PLENUM...

Page 6: ...ready assembled on the heat exchanger 8 Screws for fixing the wall power supply plate cover 9 Wall plugs 10 Screws for fixing power supply plate 11 Awl key for RESET button 12 Remote Control 1pc RC ve...

Page 7: ...be considered to install the duct without cowling For retrofit projects we recommend to use always the cowling to allow a correct installation of the trade seal The Wall Mounting Bracket and the REC...

Page 8: ...INSTALLATION ADVICES Wall Mounting Bracket Hole Diameter 110 mm External Waterproof Membrane Tube External Cowling Plenum Drill or cut a 110mm hole through wall with a 2 slope towards outside If requi...

Page 9: ...go through power supply plate Switch is not included After installing the gib board over the mounting wall bracket cut out the whole and line up the power supply plate on top Connect power supply pla...

Page 10: ...ude a main switch to power off the whole unit for e g maintenance Insert the REC Duo unit into the duct The power connectors need to line up and the plate snaps into a magnetic mount Complete external...

Page 11: ...d to set the timer operating time only extraction from 0 to 30 minutes HY Humidistat This function is present in the REC DUO 100 MHY and REC DUO 100 PLUS RC models Adjust the trimmer HY screw blue to...

Page 12: ...ned alternating rotation direction They will not need to be re synchronised REC Duo 100 PLUS RC For optimum operation installation in pairs is recommended up to a maximum of 6 devices DEVICE PAIRING O...

Page 13: ...G THE REMOTE CONTROL Remove the transparent pull tab from the remote control battery compartment The remote control is enabled to operate in a radius of approximately 20m with the battery in a good fu...

Page 14: ...signal SPEED ADJUSTMENT 2 KEYS 3 Speed 2 can be set between 70 and 100 In the factory settings mode this value is approximately 90 The setup is reflected on all synchronised machines Sequence 1 Selec...

Page 15: ...djustable timer is provided for setting maximum speed boost duration from 0 to 30 minutes see paragraph TIMER AND HUMIDISTAT At the end of the timer cycle the unit automatically returns to the pre set...

Page 16: ...E COOLING RC BUTTON 7 FLASHING YELLOW OR GREEN FORCED FLOW OPERATING RC Button 6 FLASHING WHITE LIGHT BLUE RECEIVING COMMAND FROM RC FLASHING RED PURPLE RESTORE FACTORY SETTINGS PURPLE LED INTENSITY A...

Page 17: ...E REPLACE CLEAN FILTERS NOTICE RED FLASHING LED Press the button RESET located at the base of the front support of the ventilation unit for more than 5 seconds When the LEDs turn violet the reset succ...