background image

MANUEL 

HC SERIE 

ENGLISH 

Version: 01/2018 

Please read carefully and keep for future reference.

Summary of Contents for HC Series

Page 1: ...MANUEL HC SERIE ENGLISH Version 01 2018 Please read carefully and keep for future reference ...

Page 2: ...92 Wienerwald Austria T 43223820336 E office solflex eu www solflex eu ATU 65324348 FN 337206t Always observe all relevant standards and statutory regulations Subject to change without prior notice All business transactions based on our Terms and Conditions available at www solflex eu ...

Page 3: ...nd the environment 7 5 3 Emergency procedures 7 5 3 1 Fire fighting 7 6 Product delivery 8 6 1 Unloading transport to location of installation 8 7 Installation of unit 9 7 1 Installation HC100NP HC200NP 10 7 2 Installation HC100NP SA 12 7 3 Montage HC200NP_SA 14 7 4 Montage HC Drain Pan 16 7 5 Wall mounting 17 7 6 Retrofit Fix Beam 18 7 7 Foundation Wall 19 7 8 Installation of Heat Pump Air Condit...

Page 4: ...10 kg m with hygienic coating according VDI6022 All screw connections with stainless M8 thread inserts Feet construction vibration decoupled by means of 4 rubber dampers Silentblock Ø30 H20 Functional and yet design oriented design with deflection of the air stream downwards with very low pressure loss and two acoustic weather protection grilles easy to remove by one person on the suction and disc...

Page 5: ...for installation of the acoustic housing and outdoor unit HC Feet Custom Custom made feet to ensure compatibility and prevent circulation HC Drain Pan 3 Drain pan with connection for drainage hose HC Electrical Heater Electrical heater cable for drain pan HC RAL7035 Powder coated in RAL7035 Light Grey HC RAL7015 Powder coated in RAL7015 Slate Grey HC RAL9010 Powder coated in RAL9010 Pure White HC ...

Page 6: ...ound Insulation Housing Reference source in the housing via a ball surface with 12 microphones Acoustic Data Class 2 according to DIN en ISO 3744 as a third spectrum and octave spectrum The difference between the two measurements is the sound insulation power of the noise isolating housing MP1 MP2 Sound insulation performance Sound Insulation Housing The measurement tolerance of 1 5 db a or tolera...

Page 7: ...1m distance Additionally 4 db a insulation on the side so a total of 14 db a sound insulation in this direction measured at 1m distance Due to the construction of the sound insulation of the HC100NP sound insulation housing Additionally 7 db a insulation upwards so a total of 17 db a sound insulation in this direction measured at 1m distance Additionally 8 db a insulation to the rear so a total of...

Page 8: ...Risk of serious injury from dislodged loads Do not stand under suspended loads 5 2 2 Risks from electric power Risk of electric shock from electrostatic charge of housing Earth the device 5 2 3 Risk of damage to property and the environment Serious damage to property from dropping loads please observe the instructions in section Delivery of product Serious damage to heat exchanger connections pane...

Page 9: ... incomplete deliveries cannot be considered if made too late On the construction site protect the unit against dirt impact and the elements 6 1 Unloading transport to location of installation This unit is shipped in parts on a pallet For unloading lift the unit by the pallet Too short forks can damage the acoustic housing Risk of serious injury or damage to property from dropping loads Observe the...

Page 10: ...e site must enable this to remove to have access to the built in air conditioning refrigeration and heat pump equipment Aluzinc The warranty applies to all buildings exposed to normal atmospheric corrosion factors in other words excluding those subject to permanent spraying with fresh water or salt water in the case of buildings situated in coastal areas excluding those exposed to sea spray Usage ...

Page 11: ...ll Side wall Roof air separation Acoustic louvres Silent block M8 L20 H30 Washer Ø8 Ø24 M8 Nut 1 Fix heat pump to support feet with silent block 2 Insert drain pan 3 Fix base frame to support feet with 8 screws M8 x20 4 Fix side panel to base frame with 4 screws M8 x20 5 Cut to size and apply acoustic form strips with provided self adhesive film 6 Fix side panel to base frame with 4 screws M8 x 20...

Page 12: ...n 01 2018 7 Cut to size and apply acoustic form strips with provided self adhesive film 8 Fix the roof to side panels with 6 screws M8 x20 9 Insert acoustic louvres in the structure 10 Fix acoustic louvres to side panels with 8 screws M8 x 20 ...

Page 13: ...Side Panel with Small Aphonic Grid Roof Accessories Aphonic Grid with Panel Vibration joint M8 L20 H30 Washer Ø8 Ø24 M8 Nut 1 Fix heatpump to heatpump supports with vibration joints 2 Insert condensation tray 3 Fix structure supports to heatpump supports with 8 hex head screws M8 x 20 4 Fix small aphonic grid to side panel and the side panel to structure supports with screws M8 x20 ...

Page 14: ...panel to structure supports with screws M8 x 20 7 Cut to size and apply strips adhesive felt provided 8 Fix the roof to side panels with 6 hex head screws M8 x 20 9 Insert aphonic grid and bottom panel in the structure 10 Fix aphonic grids and bottom panel to side panels with 8 hex head screws M8 x 20 ...

Page 15: ...e Panel with Small Aphonic Grid Roof Accessories Aphonic Grid With Panel Vibration joint M8 L20 H30 Washer Ø8 Ø24 M8 Nut 1 Fix heatpump to heatpump supports with vibration joints 2 Insert condensation tray 3 Fix structure supports to heatpump supports with 8 hex head screws M8 x 20 4 Fix small aphonic grid to side panel and the side panel to structure supports with screws M8 x 20 ...

Page 16: ...to side panel and the side panel to structure supports with screws M8 x 20 7 Fix the roof to side panels with 6 hex head screws M8 x 20 9 Insert aphonic grid and bottom panel in the structure 10 Fix aphonic grids and bottom panel to side panels with 8 hex head screws M8 x 20 ...

Page 17: ...Manual HC Acoustic Housing Page 16 Version 01 2018 7 4 Montage HC Drain Pan Machine to carrier and sound insulation befestitgen Insert Tub Nut M8 Washer Drain Pipette Screw on 1 ...

Page 18: ...Manual HC Acoustic Housing Page 17 Version 01 2018 7 5 Wall mounting ...

Page 19: ...Manual HC Acoustic Housing Page 18 Version 01 2018 7 6 Retrofit Fix Beam ...

Page 20: ... on the refrigeration air conditioning or heat pump unit the necessary panels can be easily removed from the acoustic housing Cleaning and maintenance of the acoustic housing Remove other dirt with a damp cloth if necessary use grease or oil dissolving detergents concentrated neutral detergent with pH between 8 and 9 Treat galvanized parts with preservation spray Regularly lubricate moving parts s...

Page 21: ...mend to carry out a grounding or lightning protection 8 4 Test run After working on the acoustic housing the person responsible must ensure that no persons are in the acoustic housing before it is put into operation again 8 5 Removal and disposal Metal parts and plastic parts are to be recycled per applicable regulations ...

Page 22: ...Manual HC Acoustic Housing Page 21 Version 01 2018 Notes ...

Page 23: ...tely contact you www sonasafe eu www solflex eu Solflex GmbH Am Feuerstein 282 2392 Wienerwald Austria 43223820336 office solflex eu www solflex eu Erste Bank AG IBAN AT702011129323600200 BIC GIBAATWWXXX UID ATU65324348 FN 337206t Gerichtsstand Wiener Neustadt Austria All business transactions based on our Terms and Conditions available at www solflex eu Subject to change without prior notice ...

Reviews: