background image

P R O D U C T   I N F O R M AT I O N  

Solar collector NANOSOL 135

Technical descrip

ti

on

Summary of Contents for NANOSOL 135

Page 1: ...PRODUCT INFORMATION Solar collector NANOSOL 135 Technical description ...

Page 2: ...nknown voltage 5m always wear safety goggles and gloves while working with an angle grinder Flat plate collectors can achieve a stationary temperature of over 200 C due to incident light The risk of burns exists at the connections of flow and return Always cover the collectors on sunny days during the installation Even regular daylight might cause the fluid in the collector to vaporize This vapor ...

Page 3: ...ctor area m2 0 966 calibration of pressure relief and non return valve bar 7 maximum working pressure bar 6 maximum testing pressure bar 9 light transmission of methacrylate 92 heat loss coefficient W K 6 85 mechanical load kg cm2 160 temperature range C 20 90 Height at 35 installation angle with horizontal installation 852 552 1 3 3 5 965 940 1080 1042 Connection for electric heating rod TECHNICAL ...

Page 4: ...essive pressure due to the vo lume increase of water while heating moreover it prevents domestic hot water from flowing back into the cold water circuit The lack of a suitable pressure relief valve causes the warranty on the storage tank to be invalided 1 2 Description of components The appliance is a storage solar water heater made up of 4 parts In the upper part there are 2 methacrylate cupo las...

Page 5: ...ay because there could be a high tempera ture Keep children away from the water heater fencing the appliance if necessary ATTENTION If the appliance is installed in Italy the pressure relief valve supplied with the appliance must be replaced with a safety group in accordance with the UNI rule EN 1487 2002 as required by The Memorandum N 9571 dated 26 03 03 issued by Ministry of Pro ductive Assets ...

Page 6: ... 100 litres of water This equals to 3 4 of the overall storage capacity of the appliance 2 4 Installation and location of the appliance The water heater is delivered in a packaging It is sup plied with the installation manual and with a pressure relief valve to be replaced with a pressure relief and non return valve in accordance with the rule EN 1487 in case the panel is installed in Italy Once t...

Page 7: ...hot water outlet of the panel ma king sure that either the pressure relief valve that is supplied with the appliance in case the unit is instal led abroad or a hydraulic safety group conforming to the rule EN 1487 2002 proceed to fill up the tank by simply opening the faucet placed along the cold water supply duct Starting Appliance is a simple storage panel needing neither pumps nor control boxes...

Page 8: ...and the hot water pipe from the water heater because they could freeze during the winter time The insulation of the tubes can be obtained by using some covering in expanded elastomer Pipe section The advisable pipe section is 1 2 However if the ap pliance is a long way from the point where hot water is used a 3 4 pipe section is suggested Solar water heater located in a garden and connected to the...

Page 9: ...compli ance with the rule EN 1487 the manufacturer will be exempted from any warranty claim on the tank 2 6 Installation o the appliance Installation of a single unit If just one appliance is installed it has to be connected to the water system directly Installation of several appliances in a row If several units are to be installed the appliances have to be connected as shown in the diagram Fores...

Page 10: ...omes soaked with water and the whole appliance has to be replaced Breaking of one cupola of of both The breaking of one or both cupolas with the consequent making of consensation between them lowers the efficiency of the appliance The cupolas will have to be replaced Making of condensation between the cupolas If the making of condensation between the cupo las is not due to their breaking but to the ...

Page 11: ...h planning formation operation and restoration of potable water systems EU Pressure equipment directive PED 97 23 EC EEC directive 89 336 EEC Electromagnetic compatibility EEC directive 73 23 EEC Low voltage EEC directive 89 292 EEC Machinery EU directive 67 548 EEC classification packaging and labelling of dange rous substances EU directive 91 155 EEC safety documents Ordinance on Hazardous Subst...

Page 12: ...andbook which can always be found on our homepage www solarbayer de This translation has been provided for informational use only Solarbayer GmbH Preith Am Dörrenhof 22 85131 Pollenfeld Phone 49 8421 93598 0 Fax 49 8421 93598 29 info solarbayer de www solarbayer de System technology made in Bavaria IStorage systems IFresh water systems IWood log boiler ISolar systems IHeat pumps ...

Reviews: