SAMWON ENG                                SU-103SR    /    SU-105DA Controller User Manual                                                                    Page 

1/4 

 

4. Sensor Connection Method

 

  Temperature Controller    SU-103SR/SU-105DA-N    Manual 

Model 

Temperature    Range 

Output 

SU-103SR 

Temperature(-40.0℃~99.9℃) 

Relay(OUT1,OUT2)

 

SU-105DA-N 

Temperature(-40.0℃~99.9℃) 

Relay(OUT1,OUT2) 

  Thank  you  for  purchasing  Samwon  ENG  product.  The  User  Manual  is 

provided  for  preventing  the  damage  and  trouble  of  product  caused  by 
carelessness and to inform the precise usage.    Please keep it in the safe place 
and refer to it when you have any doubt during using this product.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
▶  Supply power to the controller 
      Display the current temperature. 
▶  Press Set    button once.    Main output set 
      Temp value in the right picture flashing   
▶To change them, press UP & Down Key. 
      If you press UP/DN longer than 1 sec 
      Increased or decrease quickly 

※If set temp limit function   
Is working, the setting will be made   
within the range. 

▶  If you press Set once again, 
      the set temp will be saved. 
      Even if switched-off, the set value 
      will not be deleted. 
▶The current temp displayed and 
    Controller starts to control. 
▶Main Output use terminal 4~5. 

 

  Terminal 6 is used for OFF terminal   

Should not be used for Main Output.

 

※Auxiliary output(alarm/timer) use terminal 7, 8.    Refer to 9 alarm output setting 
and 10 cycle timer setting. 

 
 
▶  Only for Heater/Cooler ON/OFF control. 

      Variation(dIF) 0.1~25.0℃,0~300sec delay timer, forward/converse   
      Selection function 

▶  For Defrost function, Max 999Minutes digital cycle timer/Manual 

(only for SU-105DA) 

▶  Lock function for installer / Limit function of Set Value 
  ˚ Limit the range of set temperature by users⇒  Set limit function 
  ˚ Hysteresis, delay time, forward/converse selection⇒Lock function 
 
 

 

sensor connection method 

▶  Please connect as the right picture 

    If you connect with the changed 
    wired or use different type sensor 
   

Err

 to be displayed. 

 

  senor wire extension method 

▶  it is possible within 100m.   
      You should use the shield inside   
      cable, in order to prevent   
      input noise 

 

Sensor Input compensation   

(the current Temp is different) 

  ▶  If sensor cable is too long or   

sensor is old, there will be temp   
variation.     
At that time, use current temp 
  compensation function (rSt). 

  ▶  At the current temp displayed, press set for 3 seconds.     

If dIF displayed, release set. In order to move to rSt (temp 
compensation), press set several times. 

▶  Input the compensation temp by using up&dn.         

If you press set for 3 seconds,   
it will be saved and the current temp will be compensated.     
For example, 

   

 

 
 
 
 
 
 
 
 
 
 
 
 
① It is possible that users cannot change the default setting, by using   

lock function.   

Default 

setting 

 

Item 

Setting 

Description 

LoC 

OFF 

Locking off.    All function setting possible. 

ON 

Only locking and setting temp function 
possible. 

 

Item 

setting 

Description 

StH 

50 

Settable high temp value 50 

StL 

40 

Settable low temp value 40 

Display 

   

Current Temp / Setting Temp 

Main/Auxiliary Output 

Display

 

 

 

Main/Auxiliary Output ON/OFF Display 

OUT2 Timer Time Display 

 

At OUT2 Timer ON, If Display Value is set in time, 

  Switch ON (Refer to 8. Factory default dP2 item) 

Cooler/ Heater   
Setting Display 

 

  OUT1 rated control (tyP)setting value display

 

Setting Button 

Increase Button 

Decrease Button 

Defrost Button 

 

 

Temp , Installer Setting Button 

  Setting Value increase button   

  Setting Value decrease button       

  Manual 

Defrost 

Button

 

Terminal 

sensor 

① 

② 

③ 

Thermist 

SU-103SR 

 

White  White 

Thermist 

SU-105DA 

 

white  White 

Current Temp 

 

rSt

 Temp 

 

Displayed Temp 

20℃ 


-5℃ 


15℃ 

20℃ 

10℃ 

30℃ 

uncun 

1. Function & Name of Parts

 

up 

dn 

set 

Increase 

Decreas

Set Heater 

Set Button 

Auxiliary Output 

시  창 

제상 

DefrostButton 

OUT1

 

OUT2

 

Main Output 

시  창 

Set Cooler 

Display 

TIME

 

OUT2 Timer Time 

시  창 

set 

up 
dn 

제상 

 

 

2. Main Output Set Value Change 

 

<Current Temp> 

Coil terminal 

메인 
전원 

작동   
기계 

AC 

220V 

Main 

Pow

er 

Devi

ce 

< Terminals on Back 

sensor 

OUT1 

(Main) 

OUT2 

(Auxiliary) 

Power 

AC 

100~

220V

 

 

 

 

 

① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪

 

 

 

 

3. Functions

 

Temp sensor 

< Terminals on Back 

sensor 

OUT1 

(Main) 

OUT2 

(Auxiliary) 

Power 

AC 

100~

220V

 

 

 

 

 

① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪

 

 

 

 

5. External & Panel Dimension

 

73.2 

35

77 

(Unit: mm) 

28+

0.6

 

 

PANEL CUT OUT 

70

+0.6

 

 

6. Set Value Limit & Lock function

 

Summary of Contents for SU-105DA-N

Page 1: ...uld use the shield inside cable in order to prevent input noise Sensor Input compensation the current Temp is different If sensor cable is too long or sensor is old there will be temp variation At that time use current temp compensation function rSt At the current temp displayed press set for 3 seconds If dIF displayed release set In order to move to rSt temp compensation press set several times I...

Page 2: ...imer Output Only for SU 105DA Installer setting Item OUT2 Output of SV2 OFF Output ON Range 0 1 25 0 Auxiliary delay Timer 0 300sec Auxiliary Forward converse C Cooler H Heater ManualDefrost Time 1 999Min referto11refrigerator setting ON time Defrost operating time 0 999Min Attention 0 indefinite OFF status OFF time Defrost Stop time 0 999Min Attention 0 indefinite ON status 9 Alarm Output Setting...

Page 3: ...s displayed release set key If you press set button several times you can move to on Change the setting as below by pressing up dn and set Installer setting item Setting value description on 0 999min Select output ON time value Set as 0 continuously OFF without ON time oFF 0 999min Select Output OFF time value Set as 0 Continuously ON without OFF time If you press Set button for 3 seconds the data...

Page 4: ...ut OFF defrost output will be ON during manual defrost time If you press defrost key in front of regulator during defrost operation defrost will be immediately stopped and will normally operate in the situation of defrost output OFF Power Voltage AC100 220V 50 60Hz 10 Power Consumption Approx below 5VA Input Sensor Thermist Allowable Line Resistance within 5Ω Display Method Temperature 2 1digit of...

Reviews: