background image

ME-0515M 

 

Multipurpose Power Management Enclosure

  

Installation Manual 

1.

 

Introduction 

The ME-0515M is a multi-purpose Power Management Enclosure 
featuring a switch mode power supply that outputs power to the 
PM-05 power management module. 

The PM-05 power management module has two independent power 
channels with an isolated PTC (self-resetting fuse). Battery backup 
is available. When AC power fails, the PM-05 instantaneously (UPS) 
switches power over to a stand-by sealed lead acid (SLA) battery 
(not included) charged by a built-in battery charger. A low battery 
cutoff prevents batteries from deep discharge. 

The tough metal enclosure accommodates one 12VDC, 7Ah SLA 
battery. The enclosure is equipped with a standard IEC320-C14 AC 
inlet allowing for easy connection to mains power using a standard 
C13 power cord. The provided power lock clamp prevents 
inadvertent disconnection of the C13 plug. Multiple knockouts are 
suitable for use with 1" conduits. 

Figure 1: ME-0515M 

 

 

 

 

 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics  

SMPS

 

Input 

100 

– 240 VAC, 50/60 Hz, 1.5 A 

Output 

15 VDC, 4 A 

PM-05

 

Input 

15 VDC, 4 A 

DC Output 

12 VDC, 2 A (CH1/CH2) 

Battery Charge current 

1.5 A 

2.2

 

Environmental Characteristics 

Operating Environment 

Indoor 

Operating Temp. Range 

-10°C - 50°C (14°F - 122°F) 

Operating Humidity Range 

0% - 85% (non-condensing) 

2.3

 

Physical Characteristics 

Enclosure Dimensions 
(H x W x D) 

228 x 224 x 84 mm 

Enclosure Weight 

2.1 kg 

 

3.

 

Installation 

3.1

 

Mounting 

Make sure the mounting location is a flat surface. 

To mount the ME-0515M: 

1.  Drill holes in the wall using the enclosure back cover holes as a 

guide (Figure 2)

Figure 2: Enclosure Drill Holes 

 

2.  Insert masonry anchors into the drilled holes. 

3.  Mount the enclosure on the wall. 

4.  Once the ME-0515M is mounted, it can house a controller and 

an expansion. 

3.2

 

Connecting the Battery 

Once the control panel connections are completed, you can install 
the battery. 

To connect the battery: 

 

Make sure the AC power cable is disconnected.  

1.  Use a 7Ah sealed lead acid battery with crimp terminals (Yuasa 

Model NP7-12FR or equivalent). 

2.  Connect the backup battery red and black wires. 

If there is residual power in the battery, the system should turn 
on. If the battery is completely empty, the system will not power 
on. 

3.  Connect the AC power cable. 

3.3

 

Wiring 

Refer to the wiring diagram below. 

Figure 3. General Wiring Diagram 

 

Reviews: