Summary of Contents for 5R1UM-S08

Page 1: ...Leviton Mfg Co Inc Tech Support 1 800 824 3005 E mail appeng leviton com Web www leviton com Copyright 2011 Leviton Manufacturing Co Inc All rights reserved Subject to change without notice MTP is a registered trademark of US Conec Ltd Page 1 of 27 DI 007 5RXUM 20A 5R1UM S08 5R2UM S16 5R1UM S08 5R2UM S16 ...

Page 2: ...ve been stuck to clothing or left in work area and dispose of properly TIPS AND RECOMMENDATIONS Using isopropyl alcohol thoroughly clean exposed fiber and buffer ensuring both are free from dust oil and debris Do not lay ferrule dust covers on a dirty or dusty surface Always use proper tools and or accessories to terminate fibers and clean connector tips TABLE OF CONTENTS The following instruction...

Page 3: ... Ground Lug Mounting Hole Description The Leviton HD System Enclosure is available in 1RU and 2RU versions and provides for the mounting of HD Sys tem Evolve cassettes adapter plates and blank plates 1RU Enclosures can receive up to 8 system components 2RU Enclosures can receive up to 16 system components Provided Parts 1 1 1RU or 2RU Opt X 1000i HD System Enclosure 2 2 Removable steel powder coat...

Page 4: ...4 5 3 6 7 1 1 2 3 4 8 9 5 10 11 6 12 2 4 C 5 3 6 D 7 1 2 1 1 2 3 4 8 9 5 10 11 6 12 2 4 5 3 6 7 1 1 2 3 Panel Serving Fed From 2 2 Spiral Loop 18 1 1 Velcro Tie 4 4 Rack Mount Screw 4 4 Ground Lug 1 1 OPTIONAL ACCESSORIES Description Part Number Universal Opt X Clamp Kit for Enclosure Mounting 5RCMP KIT Universal Opt X Clamp Kit for Rack Mounting 5RCMR KIT 1RU Mounting Ear for 23 Rack 5R1RU 023 Lo...

Page 5: ... is required from the first tray lancing point to provide adequate slack for individual cassette travel A minimum of 14 inches of free slack is required to each cassette for bend radius compliant accessibility from the front side NOTE To remove tray from enclosure slide tray fully forward Warning No front pin rear stop point is provided with this enclosure Pictured Removable tray to facilitate fie...

Page 6: ...M 20A CASSETTE INSTALLATION Insert HD Evolve Cassettes Adapter Plates or Blank Plates from the front into the receiving guide of the target location HD Evolve Cassette HD Evolve Adapter Plate Blank Plate HD Evolve MTP Cassette ...

Page 7: ...Page 7 of 27 DI 007 5RXUM 20A CABLE INSTALLATION APPLICATIONS ...

Page 8: ...r a simple soap and water solution when wiping down surface area UNIVERSAL LABELING DEVICES Horizontal orientation Use 1 4 or 3 8 label tape depending on adapter plate Total label length 4 Panel section is 1 4 H x 4 L 5R1UM S08 5R2UM S16 Page 8 of 27 DI 007 5RXUM 20A 4 8 9 5 10 11 6 12 2 4 A 5 3 6 B 7 1 2 1 1 2 3 4 8 9 5 10 11 6 12 2 4 5 3 6 7 1 1 2 3 Panel 4 8 9 5 10 11 6 12 2 4 C 5 3 6 D 7 1 2 1...

Page 9: ...Leviton Manufacturing Co Inc 2222 222nd ST SE Bothell WA 98021 USA Technical Support 800 824 3005 DI 007 5RXUM 20A Page 9 of 27 DI 007 5RXUM 20A ...

Page 10: ...ion de Leviton Mfg Co Inc Soutien technique 1 800 824 3005 Courriel appeng leviton com Web www leviton com 2011 Leviton Manufacturing Co Inc Tous droits réservés Sous réserve de modifications sans préavis MTPMD est une marque déposée de US Conec Ltd Page 10 of 27 DI 007 5RXUM 20A 5R1UM S08 5R2UM S16 5R1UM S08 5R2UM S16 ...

Page 11: ...es terminaisons optiques Il faut soigneusement retirer tous les débris de fibre accrochés aux vêtements ou laissés dans l aire de travail en les éliminant de la manière prescrite CONSEILS ET RECOMMANDATIONS Au moyen d isopropanol nettoyer en profondeur les fibres et la gaine afin d en retirer toute trace de poussière d huile ou de débris Ne jamais déposer les capuchons de virole sur une surface sa...

Page 12: ...terre Description Les logements pour systèmes haute densité HD de Leviton sont offerts en versions de une ou de deux unités de bâti 1UB ou 2UB et acceptent les cassettes les plaques d adaptation et les obturateurs de la gamme Evolve Les modèles de 1UB peuvent prendre jusqu à huit composant tandis que ceux de 2UB peuvent en recevoir jusqu à 16 Pièces fournies 1 Logement Opt X 1000i pour systèmes HD...

Page 13: ...rale d enrobage de 18 po 1 1 Attache en velcro 4 4 Vis de fixation sur bâti 4 4 Borne de terre 1 1 ACCESSOIRES OPTIONNELS Description No de pièce Anneaux passe câbles universels pour logements Opt XMD 5RCMP KIT Anneaux passe câbles universels pour bâtis de logements Opt XMD 5RCMR KIT Support de fixation pour bâtis de 23 po 1UB 5R1RU 023 Verrou et clé 5L000 KAL VUE DE PROFIL illustration du modèle ...

Page 14: ... 20 po 50 cm depuis le premier point d ancrage de plateau afin d avoir suffisamment de mou pour permettre le déplacement de chaque cassette Il faut y avoir un minimum de 14 po 35 cm de mou à chaque cas sette pour assurer la conformité des rayons de courbure quand on accède au logement par l avant REMARQUE Pour retirer le plateau du logement le glisser complètement vers l avant Avertissement ce mod...

Page 15: ...D Evolve Obturateur Cassette MTP HD Evolve REMARQUE ILLUSTRATION SANS LOGEMENT NI ÉTRIERS DE GESTION POUR PLUS DE CLARTÉ ÉTAPE 2 GLISSER LA CASSETTE LA PLAQUE D ADAPTATION OU L OBTURATEUR VERS L ARRIÈRE JUSQU À CE QUE LE TAQUET S ENCLENCHE EXEMPLE DE TAQUET ENCLENCHÉ ÉTAPE 1 INSÉRER LA CASSETTE LA PLAQUE D ADAPTATION OU L OBTURATEUR DANS LES RAILS ÉTAPE 1 ÉTAPE 2 APPUYER DÉLICATEMENT POUR LIBÉRER ...

Page 16: ...ONNER DU MOU POUR PERMETTRE LES DÉPLACEMENTS DE PLATEAU FIXATION AU LOGEMENT DONNER DU MOU POUR PERMETTRE LES DÉPLACEMENTS DE PLATEAU SPIRALE D ENROBAGE RECOMMANDÉE Acheminement par l arrière vers la droite FIXATION AU PLATEAU FIXATION AU PLATEAU CÂBLAGE DE LIAISON FIXATION AU LOGEMENT DONNER DU MOU POUR PERMETTRE LES DÉPLACEMENTS DE PLATEAU CÂBLAGE DE LIAISON Acheminement par l arrière répartitio...

Page 17: ...pour essuyer ces surfaces NORMES D ÉTIQUETAGE Orientation horizontale Ruban d étiquetage de 1 4 ou de 3 8 po 6 35 ou 9 65 po selon les plaques d adaptation utilisées Longueur totale de 4 po 10 cm Chaque section de panneau mesure 1 4 po ou 6 35 mm haut sur 4 po ou 101 6 mm long 5R1UM S08 5R2UM S16 Page 17 of 27 DI 007 5RXUM 20A 4 8 9 5 10 11 6 12 2 4 A 5 3 6 B 7 1 2 1 1 2 3 4 8 9 5 10 11 6 12 2 4 5...

Page 18: ...Leviton Manufacturing Co Inc 2222 222nd ST SE Bothell WA 98021 USA Soutien technique 800 824 3005 DI 007 5RXUM 20A Page 18 of 27 DI 007 5RXUM 20A ...

Page 19: ...eviton Mfg Co Inc Tech Support 1 800 824 3005 E mail appeng leviton com Web www leviton com Copyright 2011 Leviton Manufacturing Co Inc All rights reserved Subject to change without notice Se puede cambiar sin notificar MTP es una marca registrada de Conec Ltd EE UU Page 19 of 27 DI 007 5RXUM 20A 5R1UM S08 5R2UM S16 5R1UM S08 5R2UM S16 ...

Page 20: ...ueden haber pegado en la ropa o en el área de trabajo y deséchela apropiadamente CONSEJOS Y RECOMENDACIONES Usando alcohol propanol limpie a fondo la fibra expuesta y tampón garantizando que ambos estén libres de polvo aceite y suciedad No deje el casquillo protector de polvo en una superficie sucia o con polvo Siempre use herramientas y o accesorios apropiados para terminar las fibras y puntas li...

Page 21: ...taje con terminal a tierra Descripción La caja del sistema HD de Leviton está disponible en versiones de 1RU y 2RU y para montar proporciona casetes del sistema HD Evolve placas adaptadoras y las placas en blanco Las cajas 1RU pueden recibir hasta 8 compo nentes del sistema Las cajas 2RU pueden recibir hasta 16 componentes del sistema Partes proporcionadas 1 1 Caja del sistema HD 1000i Opt X 1RU o...

Page 22: ...6 12 2 4 5 3 6 7 1 1 2 3 Panel Serving Fed From 2 2 Circuito espiral 46 cm 18 1 1 Amarrador de velcro 4 4 Tornillo de montaje 4 4 Conexión a tierra 1 1 ACCESORIOS OPCIONALES Descripción Número de parte Juego de abrazadera Universal Opt X para montaje en caja 5RCMP KIT Juego de abrazadera Universal Opt X para montaje en bastidor 5RCMR KIT Orejas de Montaje 1RU para bastidor de 58 cm 23 5R1RU 023 Se...

Page 23: ...de la primera bandeja para proporcionar holgura adecuada para recorrido del casete individual Es necesaria una holgura de 36 cm 14 para cada casete para cumplir con la curva de radio y poder tener acceso por la parte frontal NOTA Para retirar la bandeja de la caja deslice la bandeja completamente hacia adelante Advertencia No se proporciona tope frontal posterior con esta caja Se muestra Bandeja r...

Page 24: ...lacas Adaptadoras Evolve HD Placa en blanco Casete MTP Evolve HD NOTA CAJA Y ANILLOS ORGANIZA DORES DEL CORDON SACADOS PARA CLARIDAD PASO 2 DESLICE EL CASETE LA PLACA ADAPTADORA O EN BLANCO HACIA ATRAS HASTA QUE QUEDE BIEN ASEGURADA EJEMPLO ASEGURADO APROPIADO PASO 1 INSERTE EL CASETE LA PLACA ADAPTADORA O EN BLANCO EN LAS RIELES GUIA PASO 1 PASO 2 PRESIONE HACIA ABAJO SUAVEMENTE PARA SOLTAR LUEGO...

Page 25: ...CAJA PERMITIR HOLGURA PARA EL MOVIMIENTO DE LA BANDEJA ASEGURE A LA CAJA PERMITIR HOLGURA PARA EL MOVIMIENTO DE LA BANDEJA ENVOLTURA ESPIRAL RECOMEN DADA Guía de ruta posterior Izqui erda ASEGURE A LA BANDEJA ASEGURE A LA BANDEJA TRONCAL DE CA BLEADO ASEGURE A LA CAJA PERMITIR HOLGURA PARA EL MOVIMIENTO DE LA BANDEJA TRONCAL DE CA BLEADO Abertura de Guía de ruta pos terior Izquierda ASEGURE A LA B...

Page 26: ...enda usar alcohol propanol o una solución simple de agua y jabón cuando limpie el área USO DEL ETIQUETADO UNIVERSAL Orientación Horizontal Use cinta de etiquetas 0 64 ó 0 91 cm o 3 8 dependiendo de la placa adaptadora Largo total de la etiqueta 10 cm 4 Sección del panel 0 64 cm A x 10 cm L 1 4 A x 4 L 5R1UM S08 5R2UM S16 Page 26 of 27 DI 007 5RXUM 20A 4 8 9 5 10 11 6 12 2 4 A 5 3 6 B 7 1 2 1 1 2 3...

Page 27: ...Leviton Manufacturing Co Inc 2222 222nd ST SE Bothell WA 98021 USA Technical Support 800 824 3005 DI 007 5RXUM 20A Page 27 of 27 DI 007 5RXUM 20A ...

Reviews: