TH60N(E) Multi-function Infrared Ear Thermometer
Functions
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you recognize the
room temperature.
When in power off, room temperature will always be shown on the screen with
icon.
Please see the “Use of the thermometer” section to learn how to get the correct room temperature.
How to turn off Room Temperature: When in power on, press and hold the “ON/MEM” button for 5 sec. until
“
OFF”
will be shown on the screen to release the button.
Ear Temperature
The thermometer has been designed for practical use. It’s not meant to replace a visit to the doctor. Please also
remember to compare the measurement result to your regular body temperature.
Please consult with doctor if you have
health concerns.
Please see the “Use of the thermometer” section to learn how to measure the body temperature.
Surface Mode
The Surface mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. It
can help you to monitor if the object temperature is suitable for the baby or patient, for example the baby’s milk.
Please see the “Use of the thermometer” section to learn how to measure the object temperature.
Fever Alarm
If thermometer detects a body temperature
≧
37.5°C under ear mode, there will be a long beep sound followed by
three short beep sound to warn the user for potential fever.
Last Reading
When you get a new temperature reading in ear mode, the last reading will be shown on the screen (at top right corner)
with the
icon.
Memory Locations
There are total 25 sets memories for ear measurements.
When in power on, Press the “ON/MEM” button to see the temperature stored with
icon.
°C / °F Switch
In “power off” mode (The LCD only shows the room temperature). Press and hold the “SCAN” button, then
immediately press and release the “ON/MEM” button. After 3 seconds, icon “°C” will be switched to icon “°F”. (You may
use the same way to switch back to “°C”)
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press “ON/MEM” button.(see figure 1)
3. Mode selection:
3.1
Ear mode
: Press the “ON/MEM” button, the default mode of thermometer is ear mode. The thermometer is ready
for use after you see the icon on the screen and hear two beep sounds (see figure 1). In
this mode, you can get the body temperature by ear measurement.
3.2 Surface Mode
:
After power on, press and hold the “ON/MEM” button, and press the “SCAN” button
one time for “Infrared thermometer” mode
to see
icon on your LCD display (see figure2).
In this mode, you can get the target surface temperature.
4. Temperature taking:
4.1 Ear temperature measuring, points for attention:
Remarks: a. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
b. Before the measurement, please stay in a stable environment for 5mins and avoid the exercise, bath for 30mins
c. To avoid the risk of cross contamination, please clean the probe according to “
Care and cleaning
” section after each use.
d. The different temperature varies in healthy persons between different parts of the body can be between 0.2~1°C
e. Clinical repeatability: 0.23°C (<1 year old),0.22°C (1~5 years old),0.21°C (>5 years old)
** When you get a new temperature reading in ear mode, the last reading will be shown on the screen (at top right corner) with the
icon.**
Specifications
Temperature measurement range:
Ear mode: 34~42.2°C (93.2~108°F), Surface mode: -22~80°C (-7.6~176°F)
Operating temperature range: 10~40°C (50~104°F)
Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH
≦
85%
Transportation temperature shall be less than 70°C, RH
≦
95%
Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC), IEC/EN60601-1(Safety) standards.
Accuracy:
For ear mode: +/-0.2°C (0.4°F) within 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) for other range.
For surface mode: +/-0.3°C (0.5°F) within 22~42.2°C (71.6~108°F),
/-4% or +/-2°C (4°F) whichever is greater.
Fever alarm & Temperature records under “Ear mode”
°C / °F Switch mode
Battery: one lithium cell battery (CR2032 *1pcs)
This thermometer converts the ear temperature to display its “oral equivalent.”
E:LED Back Light (optional)
LED Back Light will automatically turned on after measurement, and automatically turned
off after 5 seconds.
There is no gender and age limitation for using infrared thermometer.
This is not an AP
or APG product.
Figure 1 Figure2
4.1.1 Gently pull the ear back to straighten the ear canal (Fig.4.1.1) and snugly position the probe into the ear canal, aiming towards the
membrane of the eardrum to obtain an accurate reading (Fig.4.1.2).
4.1.2 Press and hold the “SCAN” button until you hear a beep sound. Remove the probe from ear and read the temperature
measurement on the LCD.
(Rear Cover)
Figure. 4.1.1
Figure 4.1.2