background image

GEMO

GEMO

GEMO

GEMO

AT961

THERMOSTAT

         Attention       

        High Voltage,

 Double / Reinforced            NOT

            CE Mark

    Risk of Danger,   

             Risk of         

          Insulation

         Litter

         Warning         

       Electric Shock

TECHNICAL SPECIFICATION

Dimensions

: 96x96mm

Panel Cut-out

: 91x91mm

Display

: 3 Digits 7 Segment

Sensor Type

: Fe-Const, J type T/C

Control Form

: ON-OFF or Proportional - selectable

Measuring Scale

: 0 .. 400 

o

C

SET interval

: 0 .. 400 

o

C

Hysteresis Interval

: 0 .. 20 

o

C

Proportional Band

: 1 .. 30 

o

C

Control Period

: 10 .. 240 sec.

Resolution

: ± 1

 o

C

Accuracy

: ± 1 % (Over full scale)

Out Output

: Relay (NO + NC), 250VAC, 2A, Resistive load

Cold. Junc. Comp.

: 0 .. 50 

o

C (T/C)

Sensor Failure

: Out Relay is OFF in case of sensor failure, measurement out of range or
  hardware fails to measure input signal.

Supply Voltage

: 100..240VAC, 50-60Hz

Power Consumption : < 6VA

Humidity

: 80% up to 30

o

C, then linearly decreases to 50% at 50

o

C (non-condensing)

Altitude

: < 2000 m

EMC

: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)

Safety

: EN 61010-1; Pollution degree 1, measurement category 

I

, (Only light industrial

  environment, double/reinforced isolated, non-conductive pollution environment)

Protection Class

: IP20; according to EN 60529

Operation Temp.

: 0 .. 50 

o

C

Storage Temperature : -10

o

C .. 60

o

C (no icing)

Weight

: < 0.5 kg

Key

: Micro switch

Torque for screwing : Max. 0.5 N.m

no: 

normally open

nc: 

normally closed

Gürbüzo

ğ

lu Elektronik San. ve Tic. Ltd. 

Ş

ti.

http://www.gemo.com.tr

Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye

e-posta: [email protected]

Tel: +90-312-3503900, Fax: +90-312-3511117

1

Summary of Contents for AT961

Page 1: ...ailure measurement out of range or hardware fails to measure input signal Supply Voltage 100 240VAC 50 60Hz Power Consumption 6VA Humidity 80 up to 30o C then linearly decreases to 50 at 50o C non condensing Altitude 2000 m EMC EN 61000 6 1 EN 61000 6 3 Only light industrial environment Safety EN 61010 1 Pollution degree 1 measurement category I Only light industrial environment double reinforced ...

Page 2: ...e device in a well ventilated place Install the device permanently into a proper panel cut out Fix the device with two fasteners supplied with the device Only front panel must be accessible after installation is completed Do not operate the device other then the environmental conditions given in Technical Specification Do not operate the device in environments that may cause conductive pollution T...

Page 3: ...ay SET 1 30 Ct 10 240 sec Display SET 10 240 Wait 5 sec Wait 5 sec Wait 5 sec End Process Value Display FACTORY SETTINGS Hys 3 o C PbC 12 o C Ct 30 sec ERROR MESSAGE or Displays or message in case of sensor failure measurement out of range or hardware fails to measure input signal Gürbüzoğlu Elektronik San ve Tic Ltd Şti http www gemo com tr Çamlıtepe Cad No 297 3 4 Siteler Ankara Türkiye e posta ...

Page 4: ... proportional control SET SET PbC PV HEAT SET 2 CLAEANING Do not use any solvents alcohol thinners benzine acid etc or corrosive substances to clean the device Use only a dry and clean non abrasive cloth Before cleaning disconnect the power supply and mains connections Gürbüzoğlu Elektronik San ve Tic Ltd Şti http www gemo com tr Çamlıtepe Cad No 297 3 4 Siteler Ankara Türkiye e posta info gemo co...

Reviews: