DIGITAL MULTIMETER

FP-2b

USER'S MANUAL

99 Washington Street

 

Melrose, MA 02176

 

800.517.8431

 TestEquipmentDepot.com

Summary of Contents for FP-2b

Page 1: ...DIGITAL MULTIMETER FP 2b USER S MANUAL 99 Washington Street Melrose MA 02176 800 517 8431 TestEquipmentDepot com...

Page 2: ......

Page 3: ...inly SAFETY RULES paragraph The symbol on the equipment means SEE INSTRUCTION MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this man...

Page 4: ......

Page 5: ...SPECIFICATIONS 3 3 SAFETY RULES 9 3 1 General safety rules 9 3 2 Specific safety rules 10 4 OPERATING INSTRUCTIONS 11 5 MAINTENANCE 13 5 1 Shipment instructions 13 5 2 Battery replacement 13 5 3 Repla...

Page 6: ......

Page 7: ...to 100 V Automatic overrange indication by means of 1 on the display Automatic polarity indication on the DC range Resistance measurement from 0 1 up to 200 M Capacity measurement from 1 pF up to 20 F...

Page 8: ...USER S MANUAL FP 2b Page 2 Janvier 2001...

Page 9: ...to 40 C Storage temperature 10 C to 50 C Power supply 9V battery 6F22 Dimensions W 88 x H 170 x D 38 mm Weight 340 g battery included Included accessories Test leads PP 008 Case DC 231 NOTE Accuracy...

Page 10: ...ncy range 40 Hz to 1000 Hz Overload protection 700 V AC sine wave signal Indication Average calibrated in RMS of sine wave DC Current Range Resolution Accuracy 2 mA 1 A 20 mA 10 A 0 8 reading 1 dig 20...

Page 11: ...rrent 10 A in continuous mode 20 A 15 s maximum Response Average calibrated in rms of sine wave Resistance Range Resolution Accuracy 200 0 1 0 8 reading 3 dig 2 k 1 20 k 10 200 k 100 2 M 1 k 0 8 readi...

Page 12: ...nF 2 F 10 nF 4 reading 3 dig Frequency test Range Resolution Accuracy 2 kHz 1 Hz 2 reading 5 dig 20 kHz 10 Hz 1 5 reading 5 dig Overload protection 250 V DC AC rms Sensitivity 200 mV AC rms Maximum in...

Page 13: ...USER S MANUAL FP 2b Janvier 2001 Page 7 Continuity test Range Threshold 50 Overload protection 250 V DC AC rms Transistors test Range hFE Readout hFE DC gain Base current 10 A Vce voltage 3 2 V...

Page 14: ...USER S MANUAL FP 2b Page 8 Janvier 2001...

Page 15: ...to ensure safety Test leads Use this instrument under the specified environmental conditions The user is only authorized to carry out the following maintenance operations Battery replacement Fuse rep...

Page 16: ...be sure that points under test do not exceed the maximum voltage Keep measuring leads in good condition Between measurements higher than 10 A which extend near to the maximum time specified keep wait...

Page 17: ...est leads to the measurement points For currents higher than 200 mA connect the test leads to the 10 A red and COM black jacks Measuring resistance Connect the black test lead to the COM jack and the...

Page 18: ...s of the circuit under testing If continuity exists i e resistance less than about 50 built in buzzer will sound Testing transistor Set the rotary selector at hFE position and verify if transistor is...

Page 19: ...lephone number purchase receipt in the case of warranty period and problem description Freights will be charged to the client 5 2 Battery replacement When the symbol appears on the LCD display it indi...

Page 20: ...e it with a new one of the following characteristics 200 mA F 250 V Place and fix the lid again 5 4 Cleaning recommendations The cover should be cleaned by means of a light solution of detergent and w...

Page 21: ...0 IG2564...