background image

128-8147

1 of 8

1

Model  APS-520

Installation Manual

Two Way Remote Alarm System

With Start Inhibit and Dual Stage Shock Sensor

COMPONENTS:

1 Control Module
1 Four Button RF Transmitter
1 Four Button LCD Transmitter
2 Way Antenna/Receiver
1 1” X 1.75” Foam Pad
14 Pin Accessory Harness
1 Hood Pin Switch
1/4” Female Spade Connector

2 Pin Door Lock/Unlock Harness
Starter Inhibit Relay & Harness
2 Pin LED Assy
2 Pin Push-Button Valet/Program Switch
4 Pin Antenna Receivers Harness
Installation/Owners Guide
4 Phillips Head Black Drill Point Sheet
Metal Screw #8 X 1/2"
2 Stage Shock Sensor w/Harness

FEATURES:

Four Channel Receiver (Capable Of Accepting Up To 4 Transmitters)

Code Hopping Technology

Selectable Manual Override Mode

Remote Panic in all modes

Protected Valet

User Programmable Manual Override Code

7 Function

 

LED

 

(Light Emitting Diode) - Arm / Disarm / Zone 1, 2, 3 / Valet / Arming

Intrusion Alert with Memory

Audible Arm / Disarm / Defective Zone / Tamper Confirmation

Instant Siren Activation

Starter Disable

Additional Engine Immobilizer Output (optional relay required)

True Last Door Arming (hardwire only)

Defective Zone By-Pass

Active or Passive Arming Selectable

Programmable Auto Lock On / Off

Programmable Auto Unlock On / Off

Programmable Door Lock Pulse Duration

Programmable Active or Passive Door Locks

User Programmable Permanent Chirp Delete

On Command RF Chirp Delete from Transmitter

6 Tone Multi Tone Siren

RF Inhibit with ignition on

Parking Light Flasher

Plug In Dual Stage Shock Sensor

Illuminator Entry Output (optional relay required)

FCC NOTICE

This device complies with part 15 of the FCC rules. Operation of this device is subject to the
following conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for
compliance voids the users authority to operate this device.

Summary of Contents for APS-520

Page 1: ...onAlert with Memory AudibleArm Disarm Defective Zone Tamper Confirmation Instant Siren Activation Starter Disable Additional Engine Immobilizer Output optional relay required True Last DoorArming hardwire only Defective Zone By Pass Active or PassiveArming Selectable ProgrammableAuto Lock On Off ProgrammableAuto Unlock On Off Programmable Door Lock Pulse Duration ProgrammableActive or Passive Door...

Page 2: ... will cause poor or no RF reception to the control module VALET PROGRAM MANUALOVERRIDESWITCH Select a mounting location that is easily accessible to the operator of the vehicle It is not necessary to conceal the switch However concealment is recommended as it offers a higher level of security The switch can be mounted to the lower dash panel in the driver s area Inspect behind the chosen location ...

Page 3: ...ing this system into vehicles with electronic after fans it is recommended you disable the voltage sense circuit In voltage sensing applications the closer to the battery that the red wire is connected the less sensitive the voltage sense circuitry will be Moving this connection point to the fuse panel will increase the sensitivity and connecting to the courtesy lamp fuse in the vehicle will provi...

Page 4: ...ing the pre programmed transmitter button for three seconds will access channel two This is a low current output and must be connected to a relay to supply power to the trunk release or the circuit you wish to control Connect the Dark Blue wire to terminal 86 of a VF45F11 P B relay or equivalent Connect terminal 85 of the relay to a fused 12 volt source Connect the common normally open and normall...

Page 5: ...ts however always confirm that the factory relays in your particular vehicle do not exceed the rated 250 mA output of the units door lock unlock circuit Plug the 2 pin connector of the door lock unlock harness into the mating connector shell of the control module Determine the door lock circuit of the vehicle you are working on and wire according to the diagrams shown 3 Wire Ground Switched Door L...

Page 6: ...128 8147 6 of 8 6 OTHERDOORLOCKINGCIRCUITSARESHOWNINTHEFOLLOWINGDIAGRAMS ...

Page 7: ...delay time up to 60 seconds If the vehicle has delay interior lights and you wish to avoid three chirp defect zone indication normally associated with this type of interior light we suggest you learn the interior light delay To learn the light delay start with all doors closed 1 Use the transmitter to Lock Unlock Lock Unlock Lock Unlock Lock the system The LED turns on solid to confirm the system ...

Page 8: ...128 8147 8 of 8 8 2007 Audiovox Electronics Corporation 150 Marcus Blvd Hauppauge N Y 11788 128 8147 ...

Reviews: