background image

Solid Fuel Stoves Manual. Issued  - 18/07/22

LX 

LUXIMA

SOLID FUEL HEATING STOVE

 

Multi-fuel version, and Wood-only version

 

PLXMF Multi Fuel Stove
PLXWB Wood Stove.
PLXMFT Multi-Fuel 

Deluxe

 Stove

 

PLXWBT 

Wood Stove

INSTALLATION AND OPERATING INSTRUCTIONS

LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !

This   stove   exceeds   the  safety  and  performance   requirements   of  Harmonised   Standards  for   Intermittent   burning  solid   fuel
roomheaters for installation with a single dedicated chimney.

Independent thermal and emissions testing by SGS Environmental Laboratory in 2019, CEN Notified Body EU0608 UK0120

Conforms to BS EN13240:2001+A2 2004,
Emissions tested and certified to BS EN16510-1, 2019

Fuel

Wood (Beech)
Multi-fuel configuration with grate
and ashpan

Wood (Beech)
Wood-only configuration with 
flat fuel bed

Test Cycle

1.15kg over 0.75hrs

1.15kg over 0.75hrs

Settings

Primary 0, 2nd 1/3 open

Primary 0, 2nd 1/3 open

Flue Draught Pa (ins WG)

12 (0.05wg)

12 (0.05wg)

Efficiency %

75.4

74.3

Recommended Rating kW

4.9

4.9

Mean Flue Gas Temp Rise ºC

292

261

Minimum air entry requirement

2700 mm²

Minimum  Clearance to combustibles  (allow
min 150mm to non-combustibles)

500 mm

Emissions

as if  O

2

=13%

NOx mg/m³

120

149

CO %

0.07

0.12

CxHy mg/m³

52

95

Gas flow g/sec

4.6

4.6

Smoke Emission mg/m³

37

34

Other fuels

Anthracite, manufactured smokeless fuels, peat, lignite

I declare that  this information is true, these products meet the requirements  of Harmonised Standards and are fit for sale.
Signed on behalf of the manufacturer by Glyn Hughes, Design Engineer, in the European Union and in Northern Ireland at

Room 76255, PO Box 1213, Belfast BT1 9JY and in the UK at Denver House, Winster DE42DH 22. Jun. 2021

 Read these instructions ! Use only recommended fuel ! 

This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of Building Law. It must be left with
the householder where it can easily be found.
INSTALLED AT LOCATION: 

BY:

EMERGENCY CONTACT:

British Fire Manufacturers
Trentham Lakes, Stoke on Trent,  Staffordshire, England ST4 4TJ

www.bfm-europe.com

 01782 339000

These  stoves may  be  used  in  smoke  control  areas when  operated  strictly  in  accordance  with  these instructions  and with
Soliftec Smoke Advice Sheet No1 (

www.soliftec.com/smokeadvice.htm), 

when burning:

UK: 

Untreated wood logs or authorised smokeless fuels (

Exempted from s20 of the Clean Air Act 1993

)

RoI: 

Wood logs, smokeless fuels or peat briquettes, but not petroleum coke 

(Control of Atmospheric Pollution Regulations, 1970)

1

Summary of Contents for LUXIMA PLXMF

Page 1: ...500 mm Emissions as if O 2 13 NOx mg m 120 149 CO 0 07 0 12 CxHy mg m 52 95 Gas flow g sec 4 6 4 6 Smoke Emission mg m 37 34 Other fuels Anthracite manufactured smokeless fuels peat lignite I declare that this information is true these products meet the requirements of Harmonised Standards and are fit for sale Signed on behalf of the manufacturer by Glyn Hughes Design Engineer in the European Unio...

Page 2: ...ides is likely to suffice but other configurations are possible or may be necessary at the discretion of the expert installer Even beyond the safety clearances given on the front page items may still become dangerously hot take great care in siting wax paper etc AIR SUPPLY Your stove needs air to breathe there must be a permanent fresh air supply into the space in which it is installed equal to 55...

Page 3: ...sion and prevent hot fuel falling out SUMMER SHUT DOWN Before a long period of non use empty fuel and ash remove the baffle plate and leave all the air controls open to allow ventilation to reduce condensation FUELS Do avoid dusty materials like sawdust they can burn far to violently SMOKE CONTROL In certain areas special rules apply to reduce smoke nuisance Check with your local authority WOOD Tr...

Page 4: ...himney if there is something higher nearby such as a tree hill or high building Fitting an anti downdraught cowl one which can be swept through to the chimney top can cure this CHIMNEY DRAUGHT Chimney draught in use must be at least 12Pa Much higher draught may result in somewhat fiercer burning use less fuel and refuel more often This stove remains safe and controllable up to 40Pa CHIMNEY FIRE In...

Reviews: