background image

3.  Thread 3/8-16 x 2" hex head bolt with lockwasher into the bottom tapped hole

     in the bolster plate.  

Tighten the two bolts to 18 ft-lbs .

  1.  Located on the bottom of the arm assembly, loosen (3) # 6-32 phillips screws using phillips head screw driver. 
       Open arm cover.  (See Fig. 1)

2.  Insert the bolster plate into the inside of pole with tapped hole toward the base.

     Position luminaire so the top mounting hole is aligned with the top hole on the pole.
     Install Split lockwasher and flat washer to the 3/8-16 x 2" hex head bolt and bolt through 
     the top mounting hole. Install split lockwasher and nut to the end of the top bolt.

NOTE:  Square Poles: 

Use square pole adaptor.

5.  Secure the supply wires with cable tie (strain relief) on the bolster plate and in the arm.

8.  Reinstall Arm Cover.  

4.  Connect supply and ground wires to Luminaire lead wires.
     Make wire connections per NEC or applicable local codes. 

10.  Energize Lu minaire to test installation.   

Round Pole

DRILLING DETAIL

SFRA Luminaire

7.  Install photo control if used.

IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. 

                        BE SURE ALL POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.

Fig. 1

6.  Apply bead of suitable weatherproof sealant along horizontal top, left and right edges of cast mounting arm , 

     where it contacts the pole to prevent water entry. (See Fig. 2)

  9.  Install bird deterrent if applicable (See Fig. 3).

Fig. 2

INSTALLATION INSTRUCTIONS