background image

Domestic Appliances and Personal Care 

Service

Service

Service

HB 581/A

SUNSTUDIO

COMBI

Solarium

GENERAL

The full-body solarium HB 581/A is equipped with a 
30 minute timer.
After the pre-set tanning time, the appliance
automatically switches off.
The facial tanner (HP 400 lamps) can be switched on
in two steps (180/260W) by means of switch 
SK 1/SK 2.
After the facial tanner has been switched off, it 
can only be switched on again after the lamp has
cooled down for 3 minutes!
It has eleven fans - six in the canopy and four in the 
couch and one in the control unit - for adequate cooling 
of the equipment during operation and two fans for body 
cooling.
If malfunctions occur, thermal switch (SK7/SK9/SK11) 
will prevent the temperature from rising to an 
unacceptable level.
The power supply will only be switched on via the
relays (Re1/Re2) after the timer has been set.

When choosing a place for the appliance, make sure
there is enough free space around the appliance to
guarantee proper cooling.

This solarium has to be connected to 3-phase mains.

TECHNICAL DATA

Operating voltage

:

3 x 230V, 50Hz

Power consumption

:

approx. 4250W

Ballast canopy

:

3 x 100W

:

6 x 80W

Ballast couch

:

14 x 100W

Ballast power unit

:

16 x 80W

Starter canopy

:

16 x S12

:

3 x MagneTek ZG 4,5D

Starter couch

:

14 x S12

Lamp canopy

:  16 x Cleo Performance   80W
:

3 x HP 400

Lamp couch

:

14 x Cleo Performance 100W

Timer

:

30 min.

Safety class

:

double insulation

Test mark

:

CE

Length of mains cord

:

approx. 3m

Irradiation field

:

approx. 185 x 80 cm

Dimensions

:

approx. 208 x 101 x 91 cm
             ( L   x   W   x  H )

Published by Philips Domestic Appliances and Personal Care     Printed in The Netherlands      Copyright reserved     Subject to modification

©

99/11 - 00/10

4322 277 00344

SAP coding HB 581

!

Service

Information

!

Service

Information

Summary of Contents for HB 581/A

Page 1: ...er supply will only be switched on via the relays Re1 Re2 after the timer has been set When choosing a place for the appliance make sure there is enough free space around the appliance to guarantee proper cooling This solarium has to be connected to 3 phase mains TECHNICAL DATA Operating voltage 3 x 230V 50Hz Power consumption approx 4250W Ballast canopy 3 x 100W 6 x 80W Ballast couch 14 x 100W Ba...

Page 2: ...s with the fan holders out of the housing so that the fixing screws can be loosened Mark the position of the filter holders before disassembly to make sure that they can be assembled in exactly the same position when reassembling the lamp housing which is necessary to ensure that the rivets of the cover of the lamp housing 38 can be reinserted without a problem To disassemble switches SK 1 4 55 56...

Page 3: ...r parts of the lamp housing of the couch are accessible and can be disassembled ASSEMBLY Canopy When assembling the acrylic sheet 44 make sure the ornamental retaining strips 3 have been snapped in properly Always use a new spring retainer 54 when reassembling the gas pressure springs 53 When assembling the housing part 43 make sure the housing part has been properly snapped in behind the metal st...

Page 4: ...mp with your bare hands as finger prints could burn in and reduce the lamp s performance If you touch the lamp surface by accident clean it with pure alcohol New HP400 lamps may show colour differences This is not a defect but a characteristic phenomenon of lamps of this type The discolourations disappear after a short period of use If the glass pane with metal frame 59 have been disassembled the ...

Page 5: ...must be taken after approx 5 minutes in the centre of the irradiation field and at the distance indicated The following aspects must be checked or the following preliminary measurements must be taken Mains voltage 3 x 230V Room temperature approx 22 28 C Check the fans for failure free operation as optimal irradiation is only guaranteed at the correct operating temperatures Clean the reflectors th...

Page 6: ...3 16p connector female 32 4222 062 94310 r c cable 33 4822 218 10629 remote control with cable 34 9965 000 02739 set of 5 caps rings 35 9965 000 01954 end cover canopy L 36 4822 502 14539 s t screw 4 8x19 37 4822 532 12791 push rivet 6x7 5 38 9965 000 05098 cover canopy 39 12 40 9965 000 01953 end cover canopy R 41 2 42 4822 134 80191 tl Cleo Performance 80W 43 9965 000 01943 side panel back canop...

Page 7: ...80 Watt 100 Watt HB 581 A 1 2 3 4 5 9 10 11 12 13 14 15 6 7 8 14 31 32 29 33 17 16 18 19 20 21 22 23 24 25 26 27 28 30 ...

Page 8: ...45 47 48 46 34 35 37 38 40 41 42 43 44 53 54 56 55 57 39 36 63 64 65 63 couch canopy reflector diagram 68 70 69 66 68 66 66 AIR 49 50 51 52 58 59 60 61 62 67 ...

Page 9: ...µP M7 H M1 S1 L1 La1 S3 L3 La3 S2 L2 La2 S4 L4 La4 S5 L5 La5 S6 L6 La6 S7 L7 La7 S8 L8 La8 S9 L9 La9 S10 L10 La10 S11 L11 La11 S12 L12 La12 S13 L13 S14 L14 La14 La13 S15 L15 La15 S16 L16 La16 S S Re1 SK1 Re2 SK2 external switch contact R T S N C1 C2 C3 ...

Page 10: ...S10 La10 S11 La11 S12 La12 S13 S14 La14 La13 S15 La15 S16 La16 L31a L31b L31c S31 SK3 SK5 SK8 SK7 L32a L32b L32c S32 SK10 SK9 L33a L33b L33c S33 SK12 SK11 SK4 SK6 L17 La17 L18 La18 L19 La19 L20 La20 L21 La21 L22 La22 L23 La23 L24 La24 L25 La25 L26 La26 L27 La27 L28 La28 L29 La29 L30 La30 S18 S17 S19 S20 S21 S22 S23 S24 S25 S26 S27 S28 S29 S30 ...

Page 11: ...K9 SK10 SK11 SK12 La 31 HPA La 32 HPA La 33 HPA La 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 80W L32b SK3 HPA ON OFF SK4 HPA H L SK5 FAN ON OFF SK6 FAN H L N N 16 15 1413 1211 10 9 8 7 6 N N N N N N N N N N N 1 T 1 T 1 T 1 T 1 T SK 3 4 SK 4 control unit control unit L1 L16 80W L32c ...

Page 12: ...Canopy 5 2 8 11 10 6 1 9 3 4 7 100W L32a 80W L31c 80W L31b 100W L31a 211 10 9 8 7 6 5 4 3 2 1 unit L1 L16 80W L33c 80W L33b 100W L33a M8 M7 M6 M10 M9 body cooler N 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 La S ...

Page 13: ...M5 M4 M3 M2 La 100W 30 29 28 27 26 25 24 23 22 21 20 19 18 17 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W 100W L18 L17 100W 100W L19 L20 100W 100W L21 L22 100W 100W 100W 100W Couch HB 580 81 ...

Page 14: ...M5 M3 La S 30 29 28 27 26 25 24 23 22 21 20 19 18 17 H 100W 100W L30 L29 100W 100W L28 L27 L25 L26 100W 100W L24 L23 control unit 1 R 1 R 1 R 1 R 1 R 1 R 1 R N N N N N ...

Page 15: ...M1 control unit HB 581 80W L7 80W L8 80W L6 80W L5 80W L4 80W L3 80W L2 80W L1 80W L9 80W L10 80W L11 80W L12 80W L13 80W L14 80W L15 80W L16 ...

Page 16: ...ternal switch contact 7 13 remote control 15 1 TLs canopy 3 suppression capacitor 12 11 5 80W L2 80W L1 80W L15 80W L16 Power print 14 N C3 C2 C1 Re1 R N N R Re2 R SK2 T N S N R R R 1 R 1 S 1 T 1 T 1 S 1 S 1 S 1 R R S T N N N N R S T N N N ...