Page 2: ... of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most recent version as well as the supplementary clause Expanded reservation of proprietorship ICRL U 8M12 G60 Manual ...

Page 3: ...ng Electrical Wires 7 1 9 2 Requirements for Connecting the Supply Voltage 7 1 9 3 Relevant for Use in Explosion Hazard Areas Hazardous Locations Class I Division 2 8 1 9 4 FCC Note 8 2 Product Overview 9 2 1 Power Supply 9 2 2 Ethernet Ports 10BASE T 100BASE TX 10 2 3 LEDs 10 2 3 1 Device State 10 2 3 2 Port Status 11 2 3 3 ACA Connector 11 3 Installation 12 3 1 Checking the Package Contents 12 3...

Page 4: ...2021 02 4 ICRL U 8M12 G60 Manual Table of Contents ...

Page 5: ...tions and warnings Operate the ICRL U 8M12 G60 with undamaged components exclusively The ICRL U 8M12 G60 is a potted device and there are not any serviceable components In the event of a failure turn off the supply voltage and contact Pepperl Fuchs for return procedures 1 3 Certified Usage Use the following guidelines Use the ICRL U 8M12 G60 only for the application cases described in the Pepperl ...

Page 6: ...re properly trained Training as well as practical knowledge and experience make up their qualifications This is the prerequisite for grounding and labeling circuits devices and systems in accordance with current standards in safety technology Qualified personnel are aware of the dangers that exist in their work Qualified personnel are familiar with appropriate measures against these hazards in ord...

Page 7: ...accessible disconnecting device for example a switch or a plug This disconnecting device is clearly identified So in the case of an emergency it is clear which disconnecting device belongs to which power supply cable The power supply cable is suitable for the voltage the current and the physical load Pepperl Fuchs recommends a wire diameter of 0 5 mm to 0 75 mm AWG20 up to AWG18 The following requ...

Page 8: ...d operation Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequencies If it is no...

Page 9: ... to 45 VDC 2 1 Power Supply The supply voltage is connected by means of a 5 pin A coded M12 connector PG7 See Wiring the Connector for the Supply Voltage on Page 14 for more information ICRL U 8M12 G60 1 Mounting hole 2 8 Indicator plate 3 8 4 pin D coded M12 socket for 10 100 Mbps twisted pair connections See Connecting Data Cables on Page 15 for more information 4 8 Port Status LEDs See Port Sta...

Page 10: ...half duplex mode 10 Mbps full duplex mode The screw threads of the M12 ports are electrically connected to the device casing 2 3 LEDs After the supply voltage is set up the software starts and initializes itself During this process various LEDs light up 2 3 1 Device State These LEDs provide information about conditions which affect the operation of the ICRL U 8M12 G60 Ethernet Pin Assignment ICRL ...

Page 11: ...ocket with shielding that used by Pepperl Fuchs during the manufacture process LED Display Color Activity Meaning L D Link state data traffic none Device detects an invalid or missing link green lights up Device detects a valid link yellow flashing Device is transmitting and or receiving data green yellow flashing alternately Update of the configuration via the M12 interface ...

Page 12: ...socket PG7 4 Pin Female connector Safety and general information sheet 3 2 Installing and Grounding the ICRL U 8M12 G60 3 2 1 Mounting on a Flat Surface The following requirements should be met to mount the ICRL U 8M12 G60 on a flat surface Select the installation site so that the climatic threshold values listed in the technical data are observed See Technical Data on Page 16 Protect the exposed ...

Page 13: ...ICRL U 8M12 G60 Manual Installation 2021 02 13 Install the ICRL U 8M12 G60 accordingly 1 Prepare the drill holes at the installation point 2 Mount the device on a level surface with two M4 screws ...

Page 14: ...he Supply Voltage The following requirements need to be met before wiring the power supply The power supply cable is suitable for the voltage the current and the physical load Pepperl Fuchs recommends a wire diameter of 0 5 mm to 0 75 mm AWG20 up to AWG18 The permitted cable diameter for connector PG7 is 0 15 in 4 mm to 0 23 in 6 mm To ensure the watertightness of the ICRL U 8M12 G60 only use volt...

Page 15: ...ly cables and the data cables Verify that power supply cables and data cables do not run parallel over longer distances and that ideally they are installed in separate cable channels If reducing the inductive coupling is necessary verify that the power supply cables and data cables cross at a 90 angle Seal all unused connections and ports with the provided plastic protection screws Make sure the c...

Page 16: ...62 ft ASL 2000 m ASL 40 F to 158 F 40 C to 70 C 6562 ft ASL to 13123 ft ASL 40 F to 149 F 2000 m ASL to 4000 m ASL 40 C to 65 C Humidity 5 to 100 also in condensing atmospheres Air pressure without de rating Air pressure with de rating min 795 hPa 6562 ft 2000 m max 1060 hPa 1312 ft 400 m Climatic conditions during storage Ambient air temperature Temperature of the ambient air at a distance of 2 i...

Page 17: ...chs Group 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 Tel 65 67799091 E mail sales sg pepperl fuchs com DOCT 7053 2021 02 ...