background image

Included Wall Control MUST be installed prior
to Operation of this Garage Door Operator.

Safe-T-Beam

®

Safety Reverse System Must

be Installed and the Force Controls Must be
Properly Set to close door.

This Equipment meets or exceeds all Federal,
State and UL 325 Safety Requirements.

*

Will not operate twice as fast 
on a one-piece door.

3505735581

SA

VE

FOR

FUTURE

REFERENCE

Complete

with
Remote Control

and 

SERIES II Electronics

NEED HELP ?

Please call us if you are having difficulty, for any reason. 
We would like to help you.

Call: 1.800.929.3667

Web: www.overheaddoor.com

SECTION

PAGE

PRE-INSTALLATION CHECKLIST . . . . . . . . . . . . . . . . . . . 2-3
PARTS IDENTIFICATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-6

SAFETY INFORMATION & SAFETY FEATURES

. . . . . . . . . .

7

OPERATOR ASSEMBLY & INSTALLATION

. . . . . . . . . . .

8-16

OPERATOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . 

8-11

OPERATOR INSTALLATION. . . . . . . . . . . . . . . . . . . . . 

12-16

SAFE-T-BEAM

®

SYSTEM INSTALLATION

. . . . . . . . . . .

17-18

WALL CONTROL INSTALLATION

. . . . . . . . . . . . . . . . . . . . . .

19

CONNECTING POWER

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

SETTINGS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21-22

FORCE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

21

LIMIT SWITCH ADJUSTMENT. . . . . . . . . . . . . . . . . . . . . . 

22

CONTACT REVERSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

22

WIRELESS CONTROLS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23-26

BATTERY / VISOR CLIP INSTALLATION . . . . . . . . . . . . . 

23

PROGRAMMING REMOTE CONTROLS . . . . . . . . . 

23-24

WIRELESS KEYPAD INSTALLATION . . . . . . . . . . . . . . . . . 

24

PROGRAMMING WIRELESS KEYPAD . . . . . . . . . . . 

25-26

OPERATING SAFETY INSTRUCTIONS

. . . . . . . . . . . . . . . . .

26

OPERATIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . 

27

MAINTENANCE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

27-30

PERIODIC MAINTENANCE . . . . . . . . . . . . . . . . . . . . . 

27-28

TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . 

28-29

WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

30

WARRANTY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

ACCESSORIES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A

SERVICE INFORMATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

TABLE OF CONTENTS

The Genuine. The Original.

Summary of Contents for OverDrive

Page 1: ...m SECTION PAGE PRE INSTALLATION CHECKLIST 2 3 PARTS IDENTIFICATION 4 6 SAFETY INFORMATION SAFETY FEATURES 7 OPERATOR ASSEMBLY INSTALLATION 8 16 OPERATOR ASSEMBLY 8 11 OPERATOR INSTALLATION 12 16 SAFE...

Page 2: ...of light weight steel aluminum fiberglass or glass panels Additional support bracing must be added to these type doors If this is the case please contact the door distributor or manufacturer so that t...

Page 3: ...EXTENSION SPRING OR TORSION SPRING SAFE T BEAM BRACES ADDED HEADER BRACKET MOUNTING BOARD 36 POWER CORD TO 120V GROUNDED OUTLET 6 4 3 1 2 3 TYPICAL TRACK GUIDED 1 PIECE DOOR INSTALLATION 7 SECTIONAL...

Page 4: ...18 Nut Cotter Pin Clevis Pin Wire Clip 3 8 16 x 7 8 Bolt 3 8 16 Nut 10 16 x 1 1 4 Phillips Hex Head Screw 1 4 20 Nut Insulated Staple Coupler 8 32 x 1 Screw 1 4 20 x 5 8 Bolt Rubber Bumper 5 16 18 x...

Page 5: ...33 3 NOTE The Operator will not function unless the Safe T Beam System is installed and the Force Controls are properly set 1 PIECE BOOM HARDWARE EXPLODED VIEW Assembly for 10 or 12 door includes 1 S...

Page 6: ...41 6 x 1 1 4 Pan Head Screw red bag 4 42 Entrapment WARNING Label manual 1 43 Safe T Beam STB Sensor Green LED main carton 1 44 Safe T Beam STB Source Red LED main carton 1 45 Safe T Beam STB Bracket...

Page 7: ...position if anything passes through beam Safe T Reverse Contact Reversing System Automatically stops and reverses a closing door within 2 seconds of contact with an object Safe T Stop Timed Reversed S...

Page 8: ...and slide drive screw into coupler Slide boom into bracket and line up holes with those on power head Fig 1 3 Connect with bolts 2 and nuts 8 Drive screw and boom liner can slide out of boom sections...

Page 9: ...the boom at the joint and line up the holes with those in the boom Finger tighten boom clamps with bolts 10 and nuts 11 7 Attach end boom section to middle boom section to first boom section Step 6 8...

Page 10: ...t switch wires Place switches on boom with arrows pointing toward boom strap Place CLOSE limit switch brown wire 12 from boom strap Finger tighten the hold down screw 21 Lay out the wire in the channe...

Page 11: ...6 Thread wire through small hole in carriage lever Wrap wire around itself tie tight Antenna Fig 1 13 Bundle excess wire Fig 1 14 Limit switch terminal connections NOTE If your garage is equipped with...

Page 12: ...Raise door watching top edge of door Stop door when edge reaches highest point of travel Measure distance from top edge of door to floor distance H Fig 1 19 add 2 1 2 inches to H Fig 20 Draw horizont...

Page 13: ...s HIGHEST POINT OF TRAVEL Fig 1 22 Find distance H Top of door Centerline C H H FOR TRACKLESS DOORS 2 Find center of door and header Fig 1 21 Close door Measure door width Mark a vertical line C in th...

Page 14: ...1 to 1 1 2 inches above door Fig 1 27 Temporarily support power head 26 11 7 Mount power head Fig 1 29 next page 8 Close door 9 Tighten boom strap nut 11 at header bracket Fig 1 28 10 Install door bra...

Page 15: ...door bracket Fig 1 31 Contact door distributor Mount on centerline as high on the door as possible Attach using self drilling screws 56 for metal doors or Use lag screws 30 for wooden doors Check leng...

Page 16: ...or If garage has only one garage door Determine which side of garage receives most direct sunlight Fig 2 4 and place Red LED here whenever possible Fig 2 4 For multiple doors Preventing crossed signal...

Page 17: ...cord Pull cord through carriage lever until knob is 6 feet above floor Tie new overhand knot in cord at carriage lever Cut excess cord Check all hardware for tightness 16 Install light bulbs not prov...

Page 18: ...f door or its hardware is in path between lenses of source and sensor Insure that tops of lenses are between 5 6 above the floor Fig 2 9 The brackets are flexible and can be adjusted slightly if neede...

Page 19: ...nt warning label Fig 3 4 Stick label on wall near wall control NOTE Additional wall controls are available from your dealer ONLY ONE OF YOUR WALL CONTROLS MAY BE THE LIGHTED TYPE If you have a lighted...

Page 20: ...6 inches of black and white wire inside the power head Remove knock out plug strain relief and power cord Fig 4 4 Cut ground on line side of toroid Dispose of plug relief and cord 5 Install suitable e...

Page 21: ...s et r gles locales pouvant diff rer de celles des tats Unis et du Canada avant toute utilisation desdits metteurs Transmitter Compliance Statement FINE LIMIT SWITCH SET WARNING Door opens rapidly can...

Page 22: ...or using wall control Observe door runs to OPEN limit switch If not turn OPEN FORCE knob clockwise slightly Repeat running door and adjusting force knob until door runs to OPEN limit switch NOTE Set m...

Page 23: ...f red indicator blinks approximately 4 times per second programming has stopped If programming stops repeat above steps One Button Remote Control Three Button Remote Control Complete with Battery OR M...

Page 24: ...he instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful...

Page 25: ...epairs NOTE Wireless keypad will not close door if STBs are not working properly NOTE When programming wireless keypad you must be at least 24 inches from the antenna 1 Programming personal identifica...

Page 26: ...use undesired operation of the device Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment During programming door operator coul...

Page 27: ...the operator s lighting system Wireless Keypad Operates up to 3 door operators from outside the garage and includes battery saver If cover is left open keypad automatically shuts itself off and secur...

Page 28: ...CE DETECTION SYSTEM AN IMPROPERLY BALANCED DOOR DAMAGED OR WORN COUNTERBALANCE SPRING BINDING DOOR HARD WARE OR ROLLERS MAY RESULT IN A ONE BLINK SIGNAL 2 CONTACT CUSTOMER SERVICE FOR FURTHER ASSIS TA...

Page 29: ...hen stops before it s closed Door operator starts for no reason Lights will not go out Disconnect and reconnect wires on wall control Page 19 Check wiring Incompatible wall control Disconnect and use...

Page 30: ...er which has been altered or repaired by any person not expressly authorized by ODC in writing to do so This warranty does not apply to any opener or part which has been damaged or deteriorated due to...

Page 31: ...Mini Remote Control withCodeDodger Minicontrolador remoto de 2 funciones con CodeDodger Mini t l commande 2 fonctions avecCodeDodger 3 Function Wall Console with CodeDodger Consola de pared de 3 funci...

Reviews: